1、 AMSC N/A FSC 5945 MIL-PRF-6106/9E 22 September 2011 SUPERSEDING MIL-PRF-6106/9D 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC, CONTINUOUS DUTY, 60 AMP, 3PDT, ENVIRONMENTALLY SEALED This specification is approved for use by all Departments and Agencies of the Department of
2、Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL-PRF-6106. FIGURE 1. Configurations and dimensions. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6
3、106/9E 2 Inches mm Inches mm Inches mm .010 0.25 .309 7.86 1.890 48.01 .02 0.51 .375 9.53 1.900 48.26.028 0.71 .440 11.18 2.000 50.80 .032 0.81 .600 15.24 2.115 53.72.063 1.60 .625 15.88 2.313 58.75 .148 3.76 1.000 25.40 2.40 60.96.186 4.72 1.060 26.92 2.500 63.50 .240 6.10 1.375 35.18 3.032 77.01.2
4、50 6.35 1.74 44.20 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .031 (0.79 mm). 4. Weights include cover, barriers, and terminal hardware. 5. When using relay at rated 60 amps, the use of lugs per Burndy
5、 part number YAEV6C-G8 or equal is recommended. 6. Terminal temperature rise under continuous current conditions is 95C maximum. FIGURE 1. Relay, outline drawing - Continued.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3 TABLE I. Dash number and o
6、perating characteristics. Dash no. Type Coil data Time milliseconds-maximum Coil Nominal Maximum Max pickup voltage 1/ Hold voltage 1/ Drop out voltage 1/ Operate 2/ Release 3/ Bounce Volts Freq Res Volts Ampere Normal 1/ High temp test Cont current test Main Auxiliary Inrush Steady state NO NC NO N
7、C -001 1 X1, X2 28 DC - 29 1.25 .25 17 20 21.5 7.0 1.5 25 25 2 2 - - -002 1 X1, X2 28 DC - 29 1.25 .25 17 20 21.5 7.0 1.5 25 25 2 2 2 2 -003 1 X1, X2 115 400 - 124 .71 .1 85 95 100 40 10 25 55 2 2 - - -004 1 X1, X2 115 400 - 124 .71 .1 85 95 100 40 10 25 55 2 2 2 2 1/ Over the temperature range 2/ W
8、ith nominal coil voltage 3/ From nominal coil voltage TABLE II. Rated contact load (amperes per pole) (case grounded). Type of load Life operating cycles x10328 V dc 1/ 115 V ac, 1 phase 1/ 115/200 V ac, 3 phase 1/ Main Auxiliary Main Auxiliary Main Auxiliary NO NC NO NC 400 Hz 60 Hz 400 Hz 60 Hz 40
9、0 Hz 60 Hz 400 Hz 60 Hz Resistive 100 - - 3 3 60 - 3 - 60 - - - Inductive 100 - - 1.5 1.5 60 - 1.5 - 60 - - - Motor 50 - - - - 40 - - - 40 - - - Lamp - - .5 .5 - .5 - - - - Transfer load 2/ - - - - - - - Mechanical life reduced current 200 - - .75 .75 15 - .75 - 15 - - - Mixed loads 3/ 50 - - Per sp
10、ec 4 - - - 4 - - - 1/ Absence of value indicates relay is not rated for that application. 2/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating. 3/ Mixed loads to be conducted at +71C. Number of mixed loads cycles following continuous current test
11、- 5000.MIL-PRF-6106/9E 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/9E 4 REQUIREMENTS Weight: 001 and 002 - 10.5 ounces maximum. 003 and 004 - 11.5 ounces maximum. Temperature range: -55C to +71C. Maximum altitude rating: 50,000 fee
12、t 1/. Shock g-level: sine, 25 gs. Duration: 6 to 9 ms. Maximum duration contact opening: 1 ms. Vibration-sinusoidal: See table III. TABLE III. Vibration-sinusoidal. Dash No. Vibration level 5-10 Hz 10-55 Hz 55-400 Hz 400-800 Hz 800 - 2000 Hz -55C and 25C +71C -001 .08 DA .06 DA 10 gs 10 gs 10 gs 7 g
13、s -002 10 gs 8 gs 8 gs 7 gs -003 10 gs 10 gs 10 gs 7 gs -004 10 gs 8 gs 8 gs 7 gs Vibration (random): Not applicable. Acceleration: 15 gs/ Seal: Applicable specification: MIL-STD-202, method 112, test condition C, procedure IV. Leak rate: 6x10-4 STD cc/s. Strength of terminals and mounting studs: To
14、rque: Main terminals: 24 inch-pounds maximum, 18 inch-pounds recommended installation torque. Auxilary terminals: 4.4 inch-pounds maximum, 3.3 inch-pounds recommended installation torque. Insulation resistance, initial: 200 megohms minimum. After life or environmental tests: 100 megohms minimum. 1/
15、Application range can be extended to 80,000 feet by suitably encapsulating the terminals.Dielectric withstanding voltage (sea level) 2 to 5 seconds. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/9E 5 Initial 28 V dc 115 V ac After life
16、 tests 28 V dc 115 V ac Coil to case - - - - - - - - - - - - - - - - - - - - - 1250 1500 1000 1125 Auxiliary contacts - - - - - - - - - - - - - - - - - 1250 1250 1000 1000 Across open power contacts - - - - - - - - - 1250 1250 625 625 All other points - - - - - - - - - - - - - - - - - - - 1800 1800
17、1350 1350 Dielectric withstanding voltage (altitude) - 1 minute. 28 V dc 115 V ac Coil to case - - - - - - - - - - - - - - - - - 500 500 Auxiliary contacts - - - - - - - - - - - - - 500 500 All other points - - - - - - - - - - - - - - - 700 700 Maximum contact drop, initial .150 volt. After life tes
18、t .200 volt. NO (V ac) NC (V ac) Overload current 320 320 Rupture current 400 400 Duty rating: Continuous. RFI specification (applicable to coil circuits of ac operated relays): MIL-STD-461. Part number M6106/9- (dash number from table I). Qualification by similarity: See MIL-PRF-6106. Changes from
19、previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are ca
20、utioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. 1/ Number of rupture cycles after mixed loads test - 5. Referenced documents. In addition to MIL-PRF-6106, this document references th
21、e following: MIL-STD-202 MIL-STD-461 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/9E 6 Custodians: Preparing activity: Air Force - 85 DLA - CC DLA - CC Review activities: (Project 5945-2011-059) Air Force 99 NOTE: The activities liste
22、d above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-