DLA MIL-PRF-83536 4 B-2009 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY DPDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE MAGNETIC LATCH HERMETICALLY SEALED ALL WELDED TRANSIENT.pdf

上传人:孙刚 文档编号:693082 上传时间:2018-12-30 格式:PDF 页数:13 大小:109.27KB
下载 相关 举报
DLA MIL-PRF-83536 4 B-2009 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY DPDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE MAGNETIC LATCH HERMETICALLY SEALED ALL WELDED TRANSIENT.pdf_第1页
第1页 / 共13页
DLA MIL-PRF-83536 4 B-2009 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY DPDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE MAGNETIC LATCH HERMETICALLY SEALED ALL WELDED TRANSIENT.pdf_第2页
第2页 / 共13页
DLA MIL-PRF-83536 4 B-2009 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY DPDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE MAGNETIC LATCH HERMETICALLY SEALED ALL WELDED TRANSIENT.pdf_第3页
第3页 / 共13页
DLA MIL-PRF-83536 4 B-2009 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY DPDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE MAGNETIC LATCH HERMETICALLY SEALED ALL WELDED TRANSIENT.pdf_第4页
第4页 / 共13页
DLA MIL-PRF-83536 4 B-2009 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY DPDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE MAGNETIC LATCH HERMETICALLY SEALED ALL WELDED TRANSIENT.pdf_第5页
第5页 / 共13页
点击查看更多>>
资源描述

1、 MIL-PRF-83536/4B 06 January 2009 SUPERSEDING MIL-PRF-83536/4A 7 June 2004 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, MAGNETIC LATCH, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS This speci

2、fication is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-83536. FIGURE 1. Dimensions and configurations. AMSC N/A FSC 5945 INCH-POUND Inches Millimeters

3、 Ltr Min Max Min Max A - .810 - 20.57 B - .640 - 16.25 C .145 .155 3.68 3.94 D - .410 - 10.41 E .048 .058 1.22 1.47 F .101 .111 2.56 2.82 G .295 .305 7.49 7.75 H .445 .455 11.30 11.56 J .145 .155 3.68 3.94 K .185 .195 4.70 4.95 Provided by IHSNot for ResaleNo reproduction or networking permitted wit

4、hout license from IHS-,-,-MIL-PRF-83536/4B 2 FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/4B 3 Inches Millimeters Ltr Min Max Min Max A - .810 - 20.57 B - .640 - 16.25 C .020 .030

5、0.51 0.76 D .151 .161 3.83 4.09 E - 1.280 - 32.51 F 1.073 1.083 27.25 27.51 G 1.057 1.067 26.85 27.10 H .145 .155 3.68 3.94 J .128 TYP .138 TYP 3.25 TYP 3.51 TYP K - .410 - 10.41 L .307 .317 7.80 8.05 M .048 .058 1.22 1.47 N .101 .111 2.56 2.82 P .295 .305 7.49 7.75 Q .445 .455 11.30 11.56 R .145 .1

6、55 3.68 3.94 S .070 .080 1.78 2.03 T .090 .100 2.29 2.54 U .185 .195 4.70 4.95 V .136 TYP .146 TYP 3.45 TYP 3.71 TYP W 1.065 1.075 27.05 27.31 X .845 .855 21.46 21.72 Y .136 .146 3.45 3.71 Z .026 .036 0.66 0.91 AA .220 .230 5.59 5.84 BB .445 .455 11.30 11.56 FIGURE 1. Dimensions and configurations -

7、 Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/4B 4 FIGURE 1. Dimensions and configurations - Continued. Inches Millimeters Ltr Min Max Min Max A - 1.280 - 32.51 B 1.073 1.083 27.25 27.51 C 1.057 1.067 26.85 27.10 D - .810

8、- 20.57 E - .640 - 16.26 F .315 .325 8.00 8.26 G .136 .146 3.45 3.71 H .128 .138 3.25 3.51 J .307 .317 7.80 8.05 K .145 .155 3.68 3.94 L - .410 - 10.41 M .020 .030 0.51 0.76 N .048 .058 1.22 1.47 P .101 .111 2.56 2.82 Q .295 .305 7.49 7.75 R .445 .455 S .145 .155 3.68 3.94 T .185 .195 4.70 4.95 U .1

9、37 .143 3.48 3.63 V 1.065 1.075 27.05 27.30 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/4B 5 FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license f

10、rom IHS-,-,-MIL-PRF-83536/4B 6 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. Terminal numbers need not appear on relay header provided there is affixed to the relay a suitable legible c

11、ircuit diagram that identifies each terminal location specified. 5. These relays are polarized bistable. 6. Permanent magnet drive consists of a permanent magnet with its flux path switched and combined with the electro-magnet flux. 7. Applicable to horizontal flange mount only. The circuit diagram,

12、 manufacturers PIN, and the military PIN shall be marked on the near side. The remaining portion of the nameplate data shall be marked on the far side. 8. Applicable to horizontal flange mount only. Relays shall be marked with the manufacturers name or CAGE code and date code. Marking shall be with

13、the bottom of the print adjacent to the near side. 9. Socket pin terminals shall provide the operational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated contacts. Terminals, except the polarizing pin, shall be gold-plated. One system for gold plating t

14、hat may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of 50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance requirements of this specification and shall be approved by the qualifying activity. 10. Gasket shall provide a reliable

15、seal between the relay and mating socket that will meet the environmental, operational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardness 15 to 35 thickness .050 .005. Gasket material according to SAE-AMS3332 has been considered acceptable. 11. Back

16、 EMF (transient voltage): 42 V dc maximum. 12. JANTX or equivalent screened semiconductors shall be used for internal coil suppression. Relays using suppression devices shall continue to operate should the suppression circuit be in a failure mode. Diodes shall have a peak inverse voltage of 600 V dc

17、 minimum. 13. Indicated terminals shall be identified by contrasting beads. 14. Plane of critical motion for vibration and shock is Y-axis. FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8

18、3536/4B 7 REQUIREMENTS: Contact data: Load ratings: See table I. Low level: 10 to 50 A at 10 to 50 mV dc or peak ac. Intermediate current: Applicable. Mixed loads: Applicable. TABLE I. Rated contact load and cycles (amperes per pole). Type of load (high level) Cycles x 103 28 V dc 115 V ac 1 phase 4

19、00 Hz 115/200 V ac 3 phase 400 Hz Resistive Inductive Motor Lamp 100 20 100 100 5 3 2 1 5 5 3 N/A 5 5 3 N/A Life: 100,000 cycles, unless otherwise specified (see table I). Contact voltage drop or resistance: Initial contact voltage drop: 0.100 volt maximum. Rated resistive current at 6 V dc or peak

20、ac. Relays shall not make or break this load. Initial contact resistance: 0.050 ohm maximum. 50 mA max at 6 V dc or peak ac. High level life (contact voltage drop): During life: 10 percent open circuit voltage maximum. After life: 0.125 volt maximum. Intermediate current (contact resistance): During

21、 intermediate current: 3 ohms maximum. After intermediate current: 0.150 ohm maximum. Low level (contact resistance): During low level: 100 ohms maximum. After low level: 0.150 ohm maximum at 100 mA and 28 V dc. Contact bounce: 1.0 millisecond maximum. Contact stabilization time: 2.5 milliseconds ma

22、ximum. Break bounce (normally open contacts): 0.1 millisecond maximum. Overload current: 20 amperes dc, 30 amperes ac. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/4B 8 Rupture current: 25 amperes dc, 40 amperes ac. Time current rela

23、y characteristics: See table II. TABLE II. Time current relay characteristics. 1/ Successive application Amperes Time 1 2 3 4 10 15 37.5 75 1 hour 20 seconds 2 seconds .53 second 1/ All relays shall withstand overload and fault currents. Relays must be able to sustain five applications (make and car

24、ry only) of power concurrently on adjacent poles at each of four different current levels in the sequence listed in table II. Separate relays shall be tested at 28 V dc and 115/200 V ac, 400 Hz 3-phase. Cooling time between successive applications shall be 30 minutes. Tests shall be performed on bot

25、h normally open and normally closed contacts. There shall be no failures or evidence of welding or sticking and relays shall pass contact voltage drop at the conclusion. Coil data 1/: See table III. Operate time: 46 milliseconds maximum with rated coil voltage at 25C. 6 milliseconds maximum with rat

26、ed coil voltage over the temperature range. Duty rating: Continuous. Coil transient suppression: Applicable. Neutral screen: Applicable. Electrical data: Insulation resistance: Initial: 100 megohms at 500 V dc. After life or environmental tests: 50 megohms at 500 V dc. 1/ CAUTION: Due to possible in

27、teraction of relay magnetic fields, the following spacing requirements, as a minimum, shall be considered in dense packaging situations: a. Row to row assisting fields: .125 (3.18 mm). b. Row to row opposing fields: .1875 (4.763 mm). c. Side to side alternating fields: .0625 (1.588 mm). d. Side to s

28、ide like fields: .125 (3.18 mm). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/4B 9 TABLE III. Dash numbers and characteristics. 1/ Coil data Dash number 2/ At 25C Over temperature range Maximum pickup voltage Coil voltage (V dc) 3/ S

29、older pin Solder hook Socket pin Mount Rated Max Coil resistance (ohms) minimum Specified latch/ reset voltage (V dc ) 4/ Specified latch/ reset voltage (V dc ) 4/ High temper- ature test Continuous current test 001 002 003 No mount 6 7.3 38 3.2 4.5 5.0 5.7 004 005 006 RVFM 6 7.3 38 3.2 4.5 5.0 5.7

30、007 008 - HFM 6 7.3 38 3.2 4.5 5.0 5.7 009 010 011 No mount 12 14.5 160 6.5 9.0 9.9 11.25 012 013 014 RVFM 12 14.5 160 6.5 9.0 9.9 11.25 015 016 - HFM 12 14.5 160 6.5 9.0 9.9 11.25 017 018 019 No mount 28 29 5/ 650 14.5 18.0 19.8 22.5 020 021 022 RVFM 28 29 5/ 650 14.5 18.0 19.8 22.5 023 024 - HFM 2

31、8 29 5/ 650 14.5 18.0 19.8 22.5 025 026 027 No mount 48 50 1,665 24.0 36.0 40.0 44.0 028 029 030 RVFM 48 50 1,665 24.0 36.0 40.0 44.0 031 032 - HFM 48 50 1,665 24.0 36.0 40.0 44.0 1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA res

32、istive at 6 V dc maximum or peak ac open circuits are not recommended for subsequent use in low level applications. 2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed dash number. Failure rate level (percent per 10,000 cycles): L

33、, 3.0; M, 1.0; P, 0.1; R, 0.01. Example: 001L, 002R. 3/ CAUTION: The use of any coil voltages less than the rated coil voltage will compromise the operation of the relay. 4/ Latch/reset voltages as shown is for test purposes only and is not to be used for design criteria. 5/ When maximum ambient tem

34、perature does not exceed +85C, the maximum coil voltage shall be 32 V dc. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/4B 10 Dielectric withstanding voltage 2/: Coil to case Coil to coil All other points Sea level: Initial: After lif

35、e: Altitude: At 80,000 feet: At 300,000 feet: 500 350 200 375 500 350 200 375 1,000 750 250 500 Environmental characteristics: Temperature range: -70C to +125C. Maximum altitude rating: 300,000 feet. Shock (specified pulse): Applicable, MIL-STD-202, method 213, test condition C except peak value sha

36、ll be 200 gs for 6 1 ms. Contact chatter shall not exceed 10 microseconds maximum for closed contacts and 1 microsecond maximum closure for open contacts. Vibration (sinusoidal): Applicable, MIL-STD-202, method 204, 30 gs, except frequency range shall be 70 to 3,000 Hz. Contact chatter shall not exc

37、eed 10 microseconds maximum for closed contacts and 1 microsecond maximum closure for open contacts. Vibration (random): Applicable to qualification and group C inspection. Test in accordance with MIL-STD-202, method 214, test condition IG (0.4 g2/Hz, 50 to 2,000 Hz). Contact chatter shall not excee

38、d 10 microseconds maximum for closed contacts and 1 microsecond maximum closure for open contacts. Acceleration: Applicable, except 15 gs. Physical data: Dimensions and configurations: See figure 1. Weight: 0.036 pound (16.34 gs). Terminal strength: Solder hook terminals: Pull force: For 0.031 diame

39、ter terminals: 3 pounds 0.3 pound. For 0.040 diameter terminals: 5 pounds 0.5 pound. Bend: Applicable. Twist: Not applicable. 2/ Dielectric may be improved by suitable insulation of terminals and wiring after installation. Provided by IHSNot for ResaleNo reproduction or networking permitted without

40、license from IHS-,-,-MIL-PRF-83536/4B 11 Solder pin terminals: Pull force: For .031 diameter terminals: 3 pounds 0.3 pound. For .040 diameter terminals: 5 pounds 0.5 pound. Bend: Applicable. Twist: Applicable. Socket pin terminals: Pull force: For .031 diameter terminals: 3 pounds 0.3 pound. For .04

41、0 diameter terminals: 5 pounds 0.5 pound. Bend: Applicable. Twist: Not applicable. Terminal solderability: Applicable to solder pin and solder hook terminals only. Seal: Hermetic. Marking: Applicable. Part or Identifying Number (PIN): M83536/4 (dash number from table III and suffix letter designatin

42、g failure rate level). Qualification inspection: Qualification inspection and sample size: See table IV. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/4B 12 TABLE IV. Qualification inspection and sample size. 1/ Single submission Grou

43、p submission 18 units plus 1 open unit for level L at C = 0 2/ 33 units plus 1 open unit for level M at C = 0 2/ Qualification inspection as applicable M83536/4-022 M83536/4-022 M83536/4-022 M83536/4-018 M83536/4-023 M83536/4-002 M83536/4-014 M83536/4-031 18 units plus 1 open unit for level L at C =

44、 0 2/ 33 units plus 1 open unit for level M at C = 0 2/ Qualification inspection as applicable 2 units, qualification inspection table, group II, shock, vibration, acceleration, terminal strength, and seal 2 units, qualification inspection table, group II 1/ For retention of qualification or extensi

45、on of qualification to lower failure rate levels, all life test data accumulated on MIL-PRF-83536/3 may be used in addition to MIL-PRF-83536/4 data. Prior to performance of retention of qualification testing, the relay manufacturer shall preselect the sampling plan. 2/ The number of units required f

46、or qualification testing shall be increased as required in group Q5. table II of MIL-PRF-83536, if the contractor elects to test the number of units permitting one or more failures. Prior to performance of qualification testing, the relay manufacturer shall preselect the sampling plan. Supersession

47、data: See table V. TABLE V. Supersession data. Superseded PIN M6106/54- Replacement PIN M83536/4- 001 002 003 004 005 006 007 008 009 010 011 012 021 021 022 022 020 020 024 024 025 025 023 023 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate

48、where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,