DLA MIL-PRF-8805 55 J-2010 SWITCH PUSH MICROPHONE DPST NORMALLY OPEN FOOT OPERATED MOMENTARY UNSEALED AND WATERTIGHT.pdf

上传人:lawfemale396 文档编号:693131 上传时间:2018-12-30 格式:PDF 页数:5 大小:64.67KB
下载 相关 举报
DLA MIL-PRF-8805 55 J-2010 SWITCH PUSH MICROPHONE DPST NORMALLY OPEN FOOT OPERATED MOMENTARY UNSEALED AND WATERTIGHT.pdf_第1页
第1页 / 共5页
DLA MIL-PRF-8805 55 J-2010 SWITCH PUSH MICROPHONE DPST NORMALLY OPEN FOOT OPERATED MOMENTARY UNSEALED AND WATERTIGHT.pdf_第2页
第2页 / 共5页
DLA MIL-PRF-8805 55 J-2010 SWITCH PUSH MICROPHONE DPST NORMALLY OPEN FOOT OPERATED MOMENTARY UNSEALED AND WATERTIGHT.pdf_第3页
第3页 / 共5页
DLA MIL-PRF-8805 55 J-2010 SWITCH PUSH MICROPHONE DPST NORMALLY OPEN FOOT OPERATED MOMENTARY UNSEALED AND WATERTIGHT.pdf_第4页
第4页 / 共5页
DLA MIL-PRF-8805 55 J-2010 SWITCH PUSH MICROPHONE DPST NORMALLY OPEN FOOT OPERATED MOMENTARY UNSEALED AND WATERTIGHT.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5930 INCH-POUND MIL-PRF-8805/55J 3 November 2010 SUPERSEDING MIL-PRF-8805/55H 25 June 2003 PERFORMANCE SPECIFICATION SHEET SWITCH, PUSH, MICROPHONE, DPST, NORMALLY OPEN, FOOT OPERATED, MOMENTARY, UNSEALED AND WATERTIGHT This specification is approved for use by all Departments and Agenc

2、ies of the Department of Defense. The requirements for acquiring the switches described herein shall consist of this specification sheet and MIL-PRF-8805. FIGURE 1. Dimensions and configuration. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF

3、-8805/55J 2 Inches mm Inches mm .010 0.25 .858 21.79 .016 0.41 .910 23.11 .032 0.81 1.098 27.89 .070 1.78 1.312 33.32 .125 3.18 1.360 34.54 .138 3.51 1.546 39.27 .156 3.96 1.660 42.16 .250 6.35 1.812 46.02 .562 14.27 2.160 54.86 .655 16.64 2.218 56.34 .672 17.07 2.968 75.39 NOTES: 1. Dimensions are

4、in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .010. 4. Mounting hardware not furnished. 5. Lockwashers are not captive to terminal screws. 6. Dimension A is 2.218 or 2.968, see table I. 7. Dimension B is 0.910 or 1.660, see tab

5、le I. 8. Design optional within envelope dimensions shown. FIGURE 1. Dimensions and configuration - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/55J 3 REQUIREMENTS: Dimensions and configuration: See figure 1 and table I. En

6、closure design: 1 (unsealed) or 3 (watertight), see table I. Temperature characteristic: -40C to +85C. Thermal shock: In accordance with test condition A, method 107 of MIL-STD-202, except low temperature extreme shall be -40C (-40C to +85C) Shock type: 50 gs, sawtooth, in accordance with method 213

7、, test condition G, MIL-STD-202. Sinusoidal vibration grade: 1 (10 to 500 Hz). Material: Mounting bracket: Steel, corrosion resistant or equivalent. Weight: With short actuator bushing (M8805/55-001, -003, -005, -007 and -009): 0.25 pound maximum. With long actuator bushing (M8805/55-002, -004, -006

8、, and -008): 0.32 pound maximum. Operating characteristics: 10% variation from specified values acceptable after test. Actuating force: 7.0 (+4 -0) pounds for -001 thru -008 13 2 pounds for -009 Pretravel: .090 inch minimum. Total travel: .165 inch minimum. Overtravel: .050 inch minimum. Differentia

9、l travel: .050 inch minimum. Full overtravel force: 20 pounds maximum for -001 thru -008 25 pounds maximum for -009 Release force: 0.5 pounds minimum. Rated load at 28 V dc: 0.75 ampere inductive at sea level only. Overload at 28 V dc: Inductive: 1.75 amperes Minimum operating cycles: Rated load: 50

10、,000 cycles Overload: 1,000 cycles. Dielectric withstanding voltage: Altitude: 50,000 feet. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/55J 4 Terminal strength: Pull: 20 pounds. Torque: 5 inch pounds. Strength of actuating means: 20

11、pounds. Moisture resistance: (Applicable to M8805/55-005 through -009 only) Insulation resistance shall be not less than 2.5 megohms in the wet condition, and not less than 50 megohms in the dry condition. Salt spray (corrosion): Unsealed switches (M8805/55-001 through -004): Group III of the MIL-PR

12、F-8805 qualification inspection table is applicable, except no electrical test applicable following salt spray. Sand and dust: Method I. Solderability: Not applicable. Mechanical endurance: 50,000 cycles. Qualification inspection: See table II. Part or Identifying Number (PIN): See table I. TABLE I.

13、 PINs, configurations and dimensions. Part or Identifying Number PIN 1/ Seal Actuator bushing Dimensions Insert nut thread A B M8805/55-001 M8805/55-002 Unsealed Short Long 2.218 2.968 0.910 1.660 .138-40 UNF-2B M8805/55-003 M8805/55-004 Short Long 2.218 2.968 0.910 1.660 .138-32 UNF-2B M8805/55-005

14、 M8805/55-006 Watertight Short Long 2.218 2.968 0.910 1.660 .138-40 UNF-2B M8805/55-007 M8805/55-008 Short Long 2.218 2.968 0.910 1.660 .138-32 UNF-2B M8805/55-009 Short 2.218 0.910 .138-40 UNF-2B 1/ M8805/55-001 replaces and is interchangeable with canceled PIN MS25039-1. Provided by IHSNot for Res

15、aleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/55J 5 TABLE II. Qualification inspection group submission. Examination or test 1/ 2/ Basic switch Other switch samples 1/ Extent of approval Groups I, II, III, VI, VII, and VIII M8805/55-005 M8805/55-008 Group I ALL

16、 Groups I, II, III, and V M8805/55-001 1/ Group numbers refer to those inspection groups specified in the MIL-PRF-8805 qualification inspection table. 2/ If only the sealed versions, or only the unsealed versions are being qualified, the entire qualification inspection table of MIL-PRF-8805 is appli

17、cable. Reference documents: MIL-PRF-8805 MIL-STD-202 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where modifications from this revision were made. This was done as a convenience only and the Government assumes no liability whatsoever for

18、any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5930-2010-022) DLA - CC Re

19、view activities: Army - AR, AV, MI Navy - AS, MC, OS, SH Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM F1980-2007 Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices《医疗装置用无菌阻隔系统加速老化的标准指南》.pdf ASTM F1980-2007 Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices《医疗装置用无菌阻隔系统加速老化的标准指南》.pdf
  • ASTM F1980-2007(2011) Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices《医疗器械无菌阻隔系统加速老化的标准指南》.pdf ASTM F1980-2007(2011) Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices《医疗器械无菌阻隔系统加速老化的标准指南》.pdf
  • ASTM F1980-2016 Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices《医疗器械用无菌屏障系统加速老化的标准指南》.pdf ASTM F1980-2016 Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices《医疗器械用无菌屏障系统加速老化的标准指南》.pdf
  • ASTM F1983-1999(2003) Standard Practice for Assessment of Compatibiltiy of Absorbable Resorbable Biomaterials for Implant Applications《植入用可吸收和再吸收的生物材料的兼容性评定的标准操作规程》.pdf ASTM F1983-1999(2003) Standard Practice for Assessment of Compatibiltiy of Absorbable Resorbable Biomaterials for Implant Applications《植入用可吸收和再吸收的生物材料的兼容性评定的标准操作规程》.pdf
  • ASTM F1983-1999(2008) Standard Practice for Assessment of Compatibility of Absorbable Resorbable Biomaterials for Implant Applications《植入用可吸收和再吸收的生物材料的兼容性评定的标准实施规程》.pdf ASTM F1983-1999(2008) Standard Practice for Assessment of Compatibility of Absorbable Resorbable Biomaterials for Implant Applications《植入用可吸收和再吸收的生物材料的兼容性评定的标准实施规程》.pdf
  • ASTM F1983-2014 Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications《评估植入物用可吸收性生物材料的选择组织显影的标准实践规程》.pdf ASTM F1983-2014 Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications《评估植入物用可吸收性生物材料的选择组织显影的标准实践规程》.pdf
  • ASTM F1984-1999(2003) Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials《用固体材料测试血浆中整个活性的标准操作规程》.pdf ASTM F1984-1999(2003) Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials《用固体材料测试血浆中整个活性的标准操作规程》.pdf
  • ASTM F1984-1999(2008) Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials《用固体材料测试血浆中整个活性的标准实施规程》.pdf ASTM F1984-1999(2008) Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials《用固体材料测试血浆中整个活性的标准实施规程》.pdf
  • ASTM F1984-1999(2013) Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials《采用固体材料测试血清中全补体活性的标准实施规程》.pdf ASTM F1984-1999(2013) Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials《采用固体材料测试血清中全补体活性的标准实施规程》.pdf