DLA MS25032 REV K-1996 RELAY ELECTROMAGNETIC 200 AMPERES 2 PDT (N O ) TYPE II NONHERMETICALLY SEALED MECHANICALLY INTERLOCKED.pdf

上传人:explodesoak291 文档编号:696473 上传时间:2019-01-02 格式:PDF 页数:6 大小:162.75KB
下载 相关 举报
DLA MS25032 REV K-1996 RELAY ELECTROMAGNETIC 200 AMPERES 2 PDT (N O ) TYPE II NONHERMETICALLY SEALED MECHANICALLY INTERLOCKED.pdf_第1页
第1页 / 共6页
DLA MS25032 REV K-1996 RELAY ELECTROMAGNETIC 200 AMPERES 2 PDT (N O ) TYPE II NONHERMETICALLY SEALED MECHANICALLY INTERLOCKED.pdf_第2页
第2页 / 共6页
DLA MS25032 REV K-1996 RELAY ELECTROMAGNETIC 200 AMPERES 2 PDT (N O ) TYPE II NONHERMETICALLY SEALED MECHANICALLY INTERLOCKED.pdf_第3页
第3页 / 共6页
DLA MS25032 REV K-1996 RELAY ELECTROMAGNETIC 200 AMPERES 2 PDT (N O ) TYPE II NONHERMETICALLY SEALED MECHANICALLY INTERLOCKED.pdf_第4页
第4页 / 共6页
DLA MS25032 REV K-1996 RELAY ELECTROMAGNETIC 200 AMPERES 2 PDT (N O ) TYPE II NONHERMETICALLY SEALED MECHANICALLY INTERLOCKED.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、MS25032 REV K 799771i2 9088553 275 U MILITARY SPECIFICATION SHEET RELAY, ELECTROMAGNETIC, 200 AMPERES, 2 PDT, (N.O.) TYPE II, NONHERMETICALLY SEALED, MECHANICALLY INTERLOCKED INACTIVE FOR NEU DESIGN AFTER 28 SEPTEMBER 1990. NO SUPERSEDING “E STANDARD. This specification is approved for use by all De

2、partments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and the issue of the following specification listed in that issue of the Department of Defense Index of Specifications and Standards (DODISC) spe

3、cified in the solicitation: MIL-R-6106. O 3 2.?75 I I 2.093 6.875 i.010 MARKING LDCAIIDU I INCH-PWND I MS25032K SUPERSEDING MS25032J 28 September 1990 5 February 1996 ,210 HIN CLEARANCE COIL IERHIYALS STUD IHD ,375-24 UW-ZA W1. HS35650-3385T UASHLR. HS35338-i03 UASHLR. AW961-616 8 LACH RLOUIRED L TU

4、O inn ,138-32 UNC-ZA NIT. MS35649-2651 UASHCR. HS35538-98 UASHLR. AU961-6 EDllDH VIEU 4 LACH RCOUIRLD L FIGURE i. Dimensions and confiaurationS. de;o;s6changes Approved for public release; distribution is unlimited. AMSC N/A DISTRIBUTION STATEMENT 9 . RADII FSC 5945 Licensed by Information Handling

5、ServicesMS25032K CIRCUIT DIACRAH Inches mn .O10 0.25 .O93 2.36 .I38 3.51 -210 5.33 -266 6.76 .343 8.71 .375 9.52 .430 10.92 .500 12.70 Inches .SO5 .531 .625 .657 1 .o00 1 .O08 1.156 2.000 2.609 m 12.83 13.49 15.88 16.69 25.40 25.60 29.36 50.80 66.27 Inches 2.827 2.905 3.250 3.437 3.468 4.125 6.875 7

6、.688 mn 71 .81 73.79 82.55 87.30 88.09 104.77 174.63 195.28 NOTES : 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is +.O32 (0.81 mn). 4. An additional flat washer may be used for terminal seating. 5. In the event o

7、f a conflict between the text of this specification and the references cited herein, this specification shall take precedence. 6. Referenced Government documents of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DODISS) specified in the solicitatio

8、n form a part of this document to the extent specified herein. 7. Terminal nunbers shall not appear on the relay header. legible circuit diagram that identifies each terminal location. 8. Mechanical linkage shall be provided to prevent both relays from being closed at the same time. There shall be a

9、ffixed to the relay a FIGURE 1. msions and confisurat ion - Continued. 2 Licensed by Information Handling ServicesMS25032 REV K 9999932 0088553 Ob8 MSZ5032K initial 115 V ac 28 V dc I. 250 N /A 1.250 N/A 1.250 1,500 REQUIREMENTS: Dimensions and configuration: Dash number and general characteristics:

10、 See table 1. Contact data: See figure 1. Load ratings: See table II. Maximum contact drop, initial: 0.150 V. After life test: 0.175 V. Overload current (NO): 1,600 amperes. Rupture current (NO): 2,000 amperes. Coil data: See table III. Duty rating: Continuous. RFI specification: MIL-STO-461 (applic

11、able to coil circuits of ac operated relays). Electrical data: Minimum insulation resistance: Initial: 100 megohms. After life or environmental test: 50 megohms. Dielectric strength: Sea level, 2-5 seconds: After life tests 28 V dc 115 V ac 1 .o00 N /A 1 .o00 N/A 1,000 1.125 Coil to case: Aux. conta

12、cts: All other points: Altitude, 1 minute. Coil to case: Aux. contacts: All other points: O0 3 Licensed by Information Handling Services MS25032 REV K = 9999932 0088554 TT4 PIN MS25032- D1 MS25032K Type Coil Terminal type Mounting means Maximun weight (pounds 1 II dc Stud Plate 5.5 Enviromiental cha

13、racteristics: Temperature range: -55C to +71C. Maximum aititude rating: 50,000 feet. Shock, g-level: 25 gas. Duration: 6-9 ms. Maximun duration contact opening: 2 ms. Vibration, sinusoidal: See table IV. Acceleration: 10 gas. Part or Identifying Nunber (PIN): MS25032-Dl. Type of load Resi st i ve In

14、duct i ve Motor Lamp Transfer Load u Mechanical Life (reduced current) Intermediate current J./ Absence of Life 28 V dc 115 V ac, 1 phase 115/200 V ac, 10 Main Aux Main Aux Main Aux operating 3 phase U cyclef x NO NC NO NC 400 60 400 60 400 60 400 60 Hz Hz Hz Hz Hz Hz Hz Hz 50 200 150 - 10 1 O0 50 1

15、50 1 O0 1 O0 50 See MIL-R-6106 value indicates that the relay is not rated for 3 phase applications. 4 Licensed by Information Handling Services- YS25032 REV K = 9999932 0088555 930 H MS25032K o v) m al ai ?,i al U p O o 4s Io- “$! o m %Ja 2; .- O u 9 In In c O 03 - R d f o r + O c O r .- m k O o r

16、o u) .- 8 k u d d .- I o m r m d $! d .- O P r m c m .lz r u) u) al al A m m Y Licensed by Information Handling Services- MS25032 REV K c1999932 008855b 877 PIN MS25032- Dl MS25032K 5-10 HZ 10-55 HZ 55-250 HZ 250-500 HZ 500-1500 Hz .O8 DA .O6 DA 2 9s 2 gs NfA TABLE IV. yibration tsinusoidall. Vibrat

17、ion level I I I I I I Quaity assurance provisions: Group B and group C testing are not required. The manufacturer shall notify the qualifying activity in the event of any design or construction changes, and shall impose additional testing requirements as necessary. 0 The Qualified Products List (QPL

18、) associated with this inactive for new design specification will be maintained until acquisition of the product is no longer required, whereupon the specification and the QPL will be canceled. CONCLUDING MATERIAL Custodians: Navy - AS Air Force - 85 Preparing activity: Air Force - 85 Agent : OLA - ES (Project 5945-0971-02) 6 Licensed by Information Handling Services

展开阅读全文
相关资源
猜你喜欢
  • BS ISO 11907-2-1996 Plastics - Smoke generation - Determination of the corrosivity of fire effluents - Static method《塑料制品 烟雾生成 火灾流出物腐蚀性的测定 第2部分 静态法》.pdf BS ISO 11907-2-1996 Plastics - Smoke generation - Determination of the corrosivity of fire effluents - Static method《塑料制品 烟雾生成 火灾流出物腐蚀性的测定 第2部分 静态法》.pdf
  • BS ISO 11907-3-1998 Plastics - Smoke generation - Determination of the corrosivity of fire effluents - Dynamic decomposition method using a travelling furnace《塑料制品 烟雾生成 灭火废液腐蚀性的测定 .pdf BS ISO 11907-3-1998 Plastics - Smoke generation - Determination of the corrosivity of fire effluents - Dynamic decomposition method using a travelling furnace《塑料制品 烟雾生成 灭火废液腐蚀性的测定 .pdf
  • BS ISO 11907-4-1998 Plastics - Smoke generation - Determination of the corrosivity of fire effluents - Dynamic decomposition method using a conical radiant heater《塑料制品 烟雾生成 灭火废液腐蚀性.pdf BS ISO 11907-4-1998 Plastics - Smoke generation - Determination of the corrosivity of fire effluents - Dynamic decomposition method using a conical radiant heater《塑料制品 烟雾生成 灭火废液腐蚀性.pdf
  • BS ISO 11916-1-2013 Soil quality Determination of selected explosives and related compounds Method using high-performance liquid chromatography (HPLC) with ultraviolet detection《土质.pdf BS ISO 11916-1-2013 Soil quality Determination of selected explosives and related compounds Method using high-performance liquid chromatography (HPLC) with ultraviolet detection《土质.pdf
  • BS ISO 11916-2-2013 Soil quality Determination of selected explosives and related compounds Method using gas chromatography (GC) with electron capture detection (ECD) or mass spect.pdf BS ISO 11916-2-2013 Soil quality Determination of selected explosives and related compounds Method using gas chromatography (GC) with electron capture detection (ECD) or mass spect.pdf
  • BS ISO 11922-2-1997 Thermoplastics pipes for the conveyance of fluids - Dimensions and tolerances - Inch-based series《流体传输用热塑管 尺寸和公差 英制系列》.pdf BS ISO 11922-2-1997 Thermoplastics pipes for the conveyance of fluids - Dimensions and tolerances - Inch-based series《流体传输用热塑管 尺寸和公差 英制系列》.pdf
  • BS ISO 11925-3-1998 Reaction to fire tests Ignitability of building products subjected to direct impingement of flame Multi-source test《防火试验的反作用 受火焰直接影响建筑产品的可燃性 多火源试验》.pdf BS ISO 11925-3-1998 Reaction to fire tests Ignitability of building products subjected to direct impingement of flame Multi-source test《防火试验的反作用 受火焰直接影响建筑产品的可燃性 多火源试验》.pdf
  • BS ISO 11928-1-2000 Micrographics - Quality control of graphic COM recorders - Characteristics of the test frames《缩微摄影 图像COM记录器的质量控制 试验框架的特征》.pdf BS ISO 11928-1-2000 Micrographics - Quality control of graphic COM recorders - Characteristics of the test frames《缩微摄影 图像COM记录器的质量控制 试验框架的特征》.pdf
  • BS ISO 11928-2-2000 Micrographics - Quality control of graphic COM recorders - Quality criteria and control《缩微摄影技术 图形COM记录器的质量控制 质量标准和控制》.pdf BS ISO 11928-2-2000 Micrographics - Quality control of graphic COM recorders - Quality criteria and control《缩微摄影技术 图形COM记录器的质量控制 质量标准和控制》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1