1、AMSC N/A FSC 5945 INCH-POUND MS25270L 26 June 2012 SUPERSEDING MS25270K 27 November 2003 DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 5 AMPERES, 6 PDT, TYPE I, POTTED LEAD, HERMETICALLY SEALED INACTIVE FOR NEW DESIGN AFTER 5 JUN 1987. NO SUPERSEDING SPECIFICATION. This specification is approv

2、ed for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL-PRF-6106. FIGURE 1. Dimensions and configurations. Provided by IHSNot for Resale-,-,-MS25270L 2 NOTES: 1/

3、 Dimensions are in inches. 2/ Metric equivalents are given for general information only. 3/ Unless otherwise specified, tolerance is .010 (0.25 mm). 4/ Terminal numbers need not appear on relay header provided there is affixed to the relay a suitable legible circuit diagram that permanently and posi

4、tively identifies each terminal location specified hereon. 5/ The use of diodes on ac relays is optional. Actual application must be shown on label. 6/ In the event of conflict between the text of this specification and the references cited herein, the text of this specification shall take precedenc

5、e. FIGURE 1. Dimensions and configurations Continued. TABLE I. Dash numbers and characteristics. Dash number MS25270- Type Coil Terminal type Mounting or mating socket Max weight in pounds D1 I dc Lead Stud .67A1 I ac Lead Stud .67 Inches mm .005 0.13 .062 1.57.125 3.18 .152 3.86.235 5.97 .375 9.53.

6、025 15.88 1.100 27.941.187 30.15 1.531 38.892.187 55.55 24.00 609.60Provided by IHSNot for Resale-,-,-MS25270L 3 TABLE II. Operating characteristics. PIN MS25270- Coil data Time - milliseconds max Coil Rated Max 1/ Max pick-up voltage Hold vol-tage 2/ Drop out vol-tage 2/ Op-erate 3/ Rel-ease 4/ Con

7、tact Bounce Volts 1/ Freq Hz Res Volts Amp Nor- mal 2/ High temptest Cont cur-rent test Main Aux NO NC NO NC D1 X1, X2 28 dc N/A 29 0.18 18 19.8 22.5 7.0 1.5 20 20 2 2 N/A N/A A1 X1, X2 115 400 5/ N/A 122 0.04 90 95 103 30 5.0 25 50 2 2 N/A N/A 1/ CAUTION: Use of any coil voltage less than rated coi

8、l voltage will compromise the operation of the relay. 2/ Over the temperature range. 3/ With nominal coil voltage. 4/ From nominal coil voltage. 5/ MS25270-A1 may be used on 60 Hz if maximum ambient temperature is +85C (maximum coil current shall be 0.044 ampere). TABLE III. Rated contact load (ampe

9、res per pole) (case grounded). Type of load Life operating cycles x 10328 V dc 115 V ac, 1 phase 115/200 V ac, 3 phase 1/ See appropriate notes Main Aux Main Aux Main Aux NO NC NO NC 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz Resistive 100 5 5 5 4 Inductive 100 Inductive 20 3 3 3 2 Motor 10

10、0 1.5 1.5 1.5 1 Lamp 100 0.8 0.8 0.8 0.6 Transfer load 2/ Mechanical life reduced current 400 1.25 1.25 1.25 1 Mixed loads Applicable per specification 1/ Absence of value indicates relay is not rated for 3-phase application. 2/ Transfer load indicates relay is suitable for transfer between unsynchr

11、onized ac power supplies at rating indicated. Environmental characteristics. Temperature range -70C to +125C Max altitude rating 80,000 ft Shock G-level 25 gs Duration 11 ms Max duration contact opening 10 s Vibration - sinusoidal (see chart below) G-level 10 gs Frequency range 5-1,500 Hz Provided b

12、y IHSNot for ResaleNo reproduction or networking permitted without license from IHSMS25270L 4 Vibration - random Applicable spec N/A Power spectral density N/A RMS G min N/A Frequency range N/A Curve N/A High shock N/A Acceleration 15 gs Electrical characteristics. Minimum insulation resistance, ini

13、tial 100 megohms. After life or environmental tests 50 megohms. Dielectric strength (sea level). Initial After life tests Coil to case 1,050 V rms 1,000 V rms Aux contacts All other points 1,050 V rms 1,000 V rms Dielectric strength (altitude). 80,000 ft Coil to case 1,000 V rms Aux contacts All oth

14、er points 1,000 V rms Max contact drop initial 0.150 volt. After life test 0.175 volt. Overload current 20 amperes. Rupture current 25 amperes. Duty rating Continuous. RFI specification MIL-STD-461 (Applicable to coil circuits of ac operated relays). Conformance inspection. Performance of groups B a

15、nd C tests are not applicable. Group A acceptance reports shall be submitted to the preparing activity on a yearly basis in order to retain qualification for this military standard sheet. Qualification by similarity: See MIL-PRF-6106. Provided by IHSNot for Resale-,-,-MS25270L 5 NOTES Changes from p

16、revious issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cau

17、tioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-PRF-6106, this document references the following: MIL-DTL-8777 MIL-PRF-23586 SAE-AS22759/5 SAE

18、AS22759/11 MIL-STD-461 Custodians: Preparing activity: Navy - AS DLA - CC Air Force - 85 DLA - CC (Project 5945-2012-009) Review activities: Navy - EC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil/. Provided by IHSNot for Resale-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1