DLA MS27722 REV D-2003 SWITCH TOGGLE ONE POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS《环保密封综合线材终端单向触发器开关》.pdf

上传人:lawfemale396 文档编号:696859 上传时间:2019-01-02 格式:PDF 页数:4 大小:29.55KB
下载 相关 举报
DLA MS27722 REV D-2003 SWITCH TOGGLE ONE POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS《环保密封综合线材终端单向触发器开关》.pdf_第1页
第1页 / 共4页
DLA MS27722 REV D-2003 SWITCH TOGGLE ONE POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS《环保密封综合线材终端单向触发器开关》.pdf_第2页
第2页 / 共4页
DLA MS27722 REV D-2003 SWITCH TOGGLE ONE POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS《环保密封综合线材终端单向触发器开关》.pdf_第3页
第3页 / 共4页
DLA MS27722 REV D-2003 SWITCH TOGGLE ONE POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS《环保密封综合线材终端单向触发器开关》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A 1 of 4 FSC 5930 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND MS27722D 7 May 2003 SUPERSEDING MS27722C 28 September 1987 MILITARY SPECIFICATION SHEET SWITCH, TOGGLE, ONE POLE, ENVIRONMENTALLY SEALED, INTEGRATED WIRE TERMINALS This specification

2、 is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification and MIL-S-3950. FIGURE 1. Dimensions and configuration. Provided by IHSNot for ResaleNo reproduction or networking permit

3、ted without license from IHS-,-,-MS27722D 2 Inches mm Inches mm Inches mm .008 0.20 .240 6.10 .47 11.90 .012 0.30 .375 9.52 .480 12.19 .03 0.8 .38 9.70 .635 16.13 .062 1.57 .432 10.97 .69 17.50 .076 1.93 445 11.30 1.270 32.26 .130 3.30 .469 11.91 1.662 42.21 NOTES: 1. Dimensions are in inches. 2. Me

4、tric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .020 (0.51 mm) for two place decimals and .005 (0.13 mm) for three place decimals. 4. Contact installing and removal tool in accordance with M81969/14-03. 5. For hardware detail specifications, see a

5、ppendix of MIL-S-3950 6. Grommet holes or access to grommet holes, on nonfunctional terminals, optional. 7. The terminal end of the switch shall be color coded blue to indicate contact size. 8. Sealing plugs may be used in nonfunctional grommet holes when applicable. FIGURE 1. Dimensions and configu

6、ration Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27722D 3 REQUIREMENTS: Switching characteristics: See table I. Direction of movement of internal mechanism is opposite to the direction of the toggle movement. Maximum weight: .105 pound. Gromm

7、et sealing plug: MS27488-16-1. Sealing grommet: Sealing grommet shall seal on a smooth wire insulation of .068 (1.73 mm) to .103 (2.62 mm) diameters. Part or Identifying Number (PIN): See table I. Electrical ratings: See table I. Hardware: For detailed specifications, see appendix of MIL-S-3950. Tes

8、ts shall be performed in accordance with MIL-S-3950 except: a. During all tests, switches shall be fully wired with the appropriate wire and terminal contacts. b. Contact Voltage drop: The contract voltage drop with two terminals and the switch contact in series shall not exceed 8 millivolts measure

9、d from one wire contact through the contact to the other wire contacts. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27722D 4 TABLE I. Switching characteristics and electrical ratings. Circuit with toggle lever in Current capacity (amperes) 28 V

10、 dc Current capacity (amperes) 115 V ac, 60 and 400 Hz PINs Keying side Center Opposite keying side Lamp load Resistive load Inductive load Lamp load Resistive load Inductive load MS27722-21 1-2 On Off 2-3 On MS27722-22 Off None 2-3 On MS27722-23 1-2 On None 2-3 On MS27722-24 None Off 2-3 On 5 20 15

11、 3 15 10 MS27722-25 None Mom off 2-3 On MS27722-26 1-2 Mom on None 2-3 On MS27722-27 1-2 Mom on Off 2-3 Mom on MS27722-28 1-2 Mom on Off None MS27722-29 Mom off None 2-3 On MS27722-30 1-2 Mom on None Off MS27722-31 1-2 Mom on Off 2-3 On MS27722-32 None On 1-2 2-3 Mom on 4 15 10 2 15 7 MS27722-33 None On 1-2 2-3 On 5 20 15 3 15 10 Custodians: Preparing activity: Air Force - 11 DLA - CC Army - CR Navy - AS (Project 5930-1737) DLA - CC Review activities: Air Force - 99 Army - AR, AV, EA, MI Navy MC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM E2699-2010 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic (DR) Test Methods《数字射线照相(DR)试验方法用无损评估(DICOND.pdf ASTM E2699-2010 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic (DR) Test Methods《数字射线照相(DR)试验方法用无损评估(DICOND.pdf
  • ASTM E2699-2011 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic (DR) Test Methods《数字射线照相(DR)试验方法用无损评估(DICOND.pdf ASTM E2699-2011 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic (DR) Test Methods《数字射线照相(DR)试验方法用无损评估(DICOND.pdf
  • ASTM E2699-2013 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation &40 DICONDE&41 for Digital Radiographic &40 DR&41 Test Methods《数字射线成像40 DR41试验方.pdf ASTM E2699-2013 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation &40 DICONDE&41 for Digital Radiographic &40 DR&41 Test Methods《数字射线成像40 DR41试验方.pdf
  • ASTM E2700-2009 Standard Practice for Contact Ultrasonic Testing of Welds Using Phased Arrays《相控阵接触式超声对焊接单元检测的标准方法》.pdf ASTM E2700-2009 Standard Practice for Contact Ultrasonic Testing of Welds Using Phased Arrays《相控阵接触式超声对焊接单元检测的标准方法》.pdf
  • ASTM E2700-2014 Standard Practice for Contact Ultrasonic Testing of Welds Using Phased Arrays《使用相控阵进行的接触式超声波测试的标准实施规程》.pdf ASTM E2700-2014 Standard Practice for Contact Ultrasonic Testing of Welds Using Phased Arrays《使用相控阵进行的接触式超声波测试的标准实施规程》.pdf
  • ASTM E2706-2018 Standard Practice for Equipment Technology and Operations for Mobile and Plant-Based Secure Destruction Safety Requirements《移动式和基于工厂的安全销毁安全要求的设备技术和操作的标准实施规程》.pdf ASTM E2706-2018 Standard Practice for Equipment Technology and Operations for Mobile and Plant-Based Secure Destruction Safety Requirements《移动式和基于工厂的安全销毁安全要求的设备技术和操作的标准实施规程》.pdf
  • ASTM E2707-2009 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《用直接火焰冲击曝光法测定组合外墙防火焰穿透的标准试验方法》.pdf ASTM E2707-2009 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《用直接火焰冲击曝光法测定组合外墙防火焰穿透的标准试验方法》.pdf
  • ASTM E2707-2014 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《使用直接火焰接触暴露方法测定外墙组件火焰穿透性的标准试验方法》.pdf ASTM E2707-2014 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《使用直接火焰接触暴露方法测定外墙组件火焰穿透性的标准试验方法》.pdf
  • ASTM E2707-2015 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《使用直接火焰接触暴露方法测定外墙组件火焰穿透性的标准试验方法》.pdf ASTM E2707-2015 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《使用直接火焰接触暴露方法测定外墙组件火焰穿透性的标准试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1