DIN EN 622-5-2010 Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF) German version EN 622-5 2009《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf

上传人:sofeeling205 文档编号:671798 上传时间:2018-12-25 格式:PDF 页数:17 大小:566.31KB
下载 相关 举报
DIN EN 622-5-2010 Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF) German version EN 622-5 2009《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf_第1页
第1页 / 共17页
DIN EN 622-5-2010 Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF) German version EN 622-5 2009《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf_第2页
第2页 / 共17页
DIN EN 622-5-2010 Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF) German version EN 622-5 2009《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf_第3页
第3页 / 共17页
DIN EN 622-5-2010 Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF) German version EN 622-5 2009《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf_第4页
第4页 / 共17页
DIN EN 622-5-2010 Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF) German version EN 622-5 2009《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf_第5页
第5页 / 共17页
点击查看更多>>
资源描述

1、March 2010 Translation by DIN-Sprachendienst.English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS

2、79.060.20!$a0F“1621335www.din.deDDIN EN 622-5Fibreboards Specifications Part 5: Requirements for dry process boards (MDF)English translation of DIN EN 622-5:2010-03Faserplatten Anforderungen Teil 5: Anforderungen an Platten nach dem Trockenverfahren (MDF)Englische bersetzung von DIN EN 622-5:2010-03

3、Panneaux de fibres Exigences Partie 5 : Exigences pour panneaux obtenus par procd sec (MDF)Traduction anglaise de DIN EN 622-5:2010-03SupersedesDIN EN 622-5:2006-09www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considered authoritative.03.10 17DIN EN 622-

4、5:2010-03 A comma is used as the decimal marker. National foreword This standard has been prepared by CEN/TC 112 “Wood-based panels” (Secretariat: DIN, Germany). The responsible German body involved in its preparation was the Normenausschuss Holzwirtschaft und Mbel (Timber and Furniture Standards Co

5、mmittee), Technical Committee NA 042-02-15 AA Spiegelaus-schuss zu CEN/TC 112 und ISO/TC 89 Holzwerkstoffe. Amendments This standard differs from DIN EN 622-5:2006-09 as follows: a) Panel type MDF.RWH may also be used for instantaneous or short-term duration as a rigid underlay in roofing and walls.

6、 b) In Table 11, the requirement for swelling in thickness after cyclic testing has been changed for panel type MDF.RWH. Previous editions DIN EN 622-5: 1997-08, 2006-09 2 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 622-5 November 2009 ICS 79.060.20 Supersedes EN 622-5:2006English Version F

7、ibreboards - Specifications - Part 5: Requirements for dry process boards (MDF) Panneaux de fibres - Exigences - Partie 5 : Exigences pour panneaux obtenus par procd sec (MDF) Faserplatten - Anforderungen - Teil 5: Anforderungen an Platten nach dem Trockenverfahren (MDF) This European Standard was a

8、pproved by CEN on 3 October 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such natio

9、nal standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and n

10、otified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,

11、 Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of

12、exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 622-5:2009: EEN 622-5:2009 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Requirements .6 4.1 General 6 4.2 Requirements for non load-bearing boards, inc

13、luding boards for general purpose use 7 4.2.1 Requirements for boards for use in dry conditions .7 4.2.2 Requirements for boards for use in humid conditions7 4.3 Requirements for load-bearing boards .8 4.3.1 Requirements for load-bearing boards for use in dry conditions 8 4.3.2 Requirements for load

14、-bearing boards for use in humid conditions .8 4.4 Requirements for light MDF boards for non load-bearing applications, including general purpose boards 9 4.4.1 Requirements for boards for use in dry conditions .9 4.4.2 Requirements for boards for use in humid conditions. 10 4.5 Requirements for ult

15、ra-light MDF boards for non load-bearing applications, including general purpose boards . 10 4.6 Requirements for boards for use in rigid underlays in roofing and walls 11 5 Verification of compliance . 12 5.1 General . 12 5.2 External control . 12 5.3 Factory production control 12 6 Supplementary p

16、roperties . 12 7 Marking 13 7.1 Boards marketed within the European Economic Area for construction applications. 13 7.2 Other boards . 13 Annex A (normative) Boil test according to EN 1087-1 - Modified procedure . 14 Bibliography . 15 Tables Table 1 Load duration category . 5 Table 2 Examples of loa

17、d-duration assignment 6 Table 3 Requirements for general purpose boards for use in dry conditions (type MDF) 7 Table 4 Requirements for general purpose boards for use in humid conditions (type MDF.H) . 7 Table 5 Requirements for load-bearing boards for use in dry conditions (type MDF.LA) 8 Table 6 R

18、equirements for load-bearing boards for use in humid conditions (MDF.HLS) . 9 Table 7 Requirements for light MDF boards for use in dry conditions (type L-MDF) 9 Table 8 Requirements for light MDF boards for use in humid conditions (type L.MDF.H) . 10 Table 9 Requirements for ultra-light MDF boards f

19、or use in dry conditions (type UL1-MDF) 10 Table 10 Requirements for ultra-light MDF boards for use in dry conditions (type UL2-MDF) 11 Table 11 Requirements for use in rigid underlays in roofs and walls (type MDF.RWH) 11 Table 12 Maximum interval between test . 12 Table 13 Supplementary properties

20、12 DIN EN 622-5:2010-03 EN 622-5:2009 (E) 3 Foreword This document (EN 622-5:2009) has been prepared by Technical Committee CEN/TC 112 “Wood-based panels”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an id

21、entical text or by endorsement, at the latest by May 2010, and conflicting national standards shall be withdrawn at the latest by May 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held respo

22、nsible for identifying any or all such patent rights. This document supersedes EN 622-5:2006. This standard is one of a series specifying requirements for fibreboards. The other parts of this series are listed in Clause 2 and in the bibliography. Compared to EN 622-5:2006 the following modifications

23、 have been made: a) Panel type MDF.RWH also intended for instantaneous or short-term load duration as a rigid underlay in roofing and walls; b) Requirement for swelling in thickness after cyclic testing changed for panel type MDF.RWH in Table 11. According to the CEN/CENELEC Internal Regulations, th

24、e national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, No

25、rway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. DIN EN 622-5:2010-03 EN 622-5:2009 (E) 4 1 Scope This European Standard specifies the requirements for dry process boards (MDF) as defined in EN 316. The values listed in this European Standard re

26、late to product properties but they are not characteristic values to be used in design calculations1). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the l

27、atest edition of the referenced document (including any amendments) applies. EN 310, Wood-based panels Determination of modulus of elasticity in bending and of bending strength EN 311, Wood-based panels Surface soundness Test method EN 317, Particleboards and fibreboards Determination of swelling in

28、 thickness after immersion in water EN 318, Wood based panels Determination of dimensional changes associated with changes in relative humidity EN 319, Particleboards and fibreboards Determination of tensile strength perpendicular to the plane of the board EN 320, Fibreboards Determination of resist

29、ance to axial withdrawal of screws EN 321, Wood-based panels Determination of moisture resistance under cyclic test conditions EN 326-1, Wood-based panels Sampling, cutting and inspection Part 1: Sampling and cutting of test pieces and expression of test results EN 326-2, Wood-based panels Sampling,

30、 cutting and inspection Part 2: Quality control in the factory EN 326-3, Wood-based panels Sampling, cutting and inspection Part 3: Inspection of an isolated lot of panels EN 382-1, Fibreboards Determination of surface absorption Part 1: Test method for dry process fibreboards EN 622-1, Fibreboards

31、Specifications Part 1: General requirements EN 1087-1:1995, Particleboards Determination of moisture resistance Part 1: Boil test EN 12871, Wood-based panels Performance specifications and requirements for load bearing boards for use in floors, walls and roofs EN 13271, Timber fasteners Characterist

32、ic load-carrying capacities and slip-moduli for connector joints EN 13446, Wood-based panels Determination of withdrawal capacity of fasteners 1) Such characteristic values (e.g. for use in design calculation in EN 1995-1-1) are either given in EN 12369-1 or derived by testing according to EN 789, E

33、N 1058 and ENV 1156. DIN EN 622-5:2010-03 EN 622-5:2009 (E) 5 EN 13986:2004, Wood-based panels for use in construction Characteristics, evaluation of conformity and marking ISO 3340, Fibre building boards Determination of sand content 3 Terms and definitions For the purposes of this document, the te

34、rms and definitions given in EN 13986:2004 and the following apply. 3.1 dry conditions conditions corresponding to service class 1 of EN 1995-1-1 which is characterized by a moisture content in the material corresponding to a temperature of 20 C and a relative humidity of the surrounding air only ex

35、ceeding 65 % for a few weeks per year NOTE Boards of this type are suitable for use only in hazard class 1 of EN 335-3. 3.2 humid conditions conditions corresponding to service class 2 of EN 1995-1-1 which is characterized by a moisture content in the material corresponding to a temperature of 20 C

36、and a relative humidity of the surrounding air only exceeding 85 % for a few weeks per year NOTE Boards of this type are suitable for use in hazard classes 1 and 2 of EN 335-3. 3.3 general purpose use use in non load-bearing applications not otherwise specified 3.4 non load-bearing use use in non lo

37、ad-bearing conditions, e.g. as part of a building or construction 3.5 load-bearing use structural use use in a load-bearing construction, i.e. an organized assembly of connected parts designed to provide mechanical resistance and stability to the works 3.6 load duration class class characterized by

38、the effect of a constant load acting for a certain period of time in the life of the structure NOTE 1 The load duration classes are defined in EN 1995-1-1, see Table 1. Table 1 Load duration category Load duration class Order of accumulated duration of characteristic load Permanent More than ten yea

39、rs Long-term six months to ten years Medium-term one week to six months Short-term Less than one week Instantaneous DIN EN 622-5:2010-03 EN 622-5:2009 (E) 6 NOTE 2 Examples of load-duration assignment are given in Table 2. Since climatic loads (snow, wind) vary between countries, the assignment of l

40、oad-duration classes may be specified in the national annex. Table 2 Examples of load-duration assignment Load duration class Examples of loading Permanent Self weight Long-term Storage Medium-term Imposed floor load, snow Short-term Snow, wind Instantaneous Wind, accidental load 4 Requirements 4.1

41、General Dry process boards shall comply with the general requirements of EN 622-1 together with the relevant requirements set out in 4.2, 4.3, 4.4, 4.5 and 4.6 of this European Standard. Some supplementary properties and their appropriate test methods are given in Clause 6. The requirements in Table

42、s 3 to 11 shall be met by 5 percentile values (95 percentile values in the case of swelling in thickness), based on the mean test values for individual panels and calculated in accordance with EN 326-1. In the case of swelling in thickness, they shall be equal to or less than the values in the table

43、s, and in the case of all other properties, they shall be equal to or greater than the values in Tables 3 to 11. The values in Tables 3 to 11 for both bending strength and modulus of elasticity shall apply to test results obtained in the weakest direction in the plane of the panel. Properties not re

44、quired for specific thickness ranges are marked “. With the exception of swelling in thickness and internal bond after boil test (see Tables 4, 6, 8 and 11), the values given in the tables are characterised by a moisture content in the material corresponding to a temperature of 20 C and a relative h

45、umidity of 65 %. The values given for swelling in thickness and internal bond after boil test are characterised by a moisture content in the material corresponding to a temperature of 20 C and a relative humidity of 65 % before the treatment (immersion in water or boil treatment). The moisture resis

46、tance of dry process boards for use in humid conditions (see Tables 4, 6, 8 and 11) is assessed by showing compliance with either one of two options: Option 1: Swelling in thickness and internal bond after cyclic test (according to EN 321); Option 2: Internal bond after immersion in boiling water (a

47、ccording to EN 1087-1:1995), with the modified procedure given in Annex A. When verifying compliance by external control, only the test option performed and notified by the manufacturer shall be carried out. If the option is unknown, it will be necessary to carry out both sets of procedures, even th

48、ough compliance with only one set of specifications is required. DIN EN 622-5:2010-03 EN 622-5:2009 (E) 7 4.2 Requirements for non load-bearing boards, including boards for general purpose use 4.2.1 Requirements for boards for use in dry conditions Table 3 specifies the requirements for general purp

49、ose boards for use in dry conditions, particularly interior fitments including furniture. Table 3 Requirements for general purpose boards for use in dry conditions (type MDF) Property Test method Unit Ranges of nominal thickness mm 1,8to 2,5 2,5to 4 4to 6 6to 9 9 to 12 12 to 19 19 to 30 30to 45 45Swelling in thickness 24 h EN 317 % 45 35 30 17 15 12 10 8 6 Internal bond EN 319 N/mm20,65 0,65 0,65 0,65 0,60 0,55 0,55 0,50 0,50Bending strength EN 310 N/mm223 23 23 23 22 20 18

展开阅读全文
相关资源
  • DIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdfDIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdf
  • DIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdfDIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdf
  • DIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdfDIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdf
  • DIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdfDIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdf
  • DIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdfDIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdf
  • DIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdfDIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdf
  • DIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdfDIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdf
  • DIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdfDIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdf
  • DIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdfDIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdf
  • DIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdfDIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > DIN

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1