1、 AMSC N/A FSC 4130 MS35845F 8 APRIL 2010 SUPERSEDING MS35845E 19 NOVEMBER 1971 MILITARY SPECIFICATION SHEET DEHYDRATORS, DESICCANT, REFRIGERANT - 12 This specification sheet is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product d
2、escribed herein shall consist of this specification sheet and MIL-D-22825. EXTERNAL FLARE CONNECTIONS IN ACCORDANCE WITH SAE-J513ABINCH-POUND INACTIVE FOR NEW DESIGN AFTER 6 February 1996. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS35845F 2 TA
3、BLE I. Dash numbers and dimensions DASH NO. DIMENSIONS FLARE CONNECTION SIZE CAPACITY A .500 B MAX. O.D. WATER (MINIMUM AT 125 F) DROPS DRYING TONNAGE TR -1 6.000 2.593 .375 80 2 -2 6.750 3.062 .375 120 3 -3 6.875 3.062 .500 200 5 -4 10.250 3.562 .625 300 7.5 -5 10.312 3.562 .625 400 10 REQUIREMENTS
4、: 1. Rating condition: Dehydrators shall comform to the standard rating condition specified in Air-Conditioning, Heating and Refrigeration Institute standard ARI710. 2. Materials: A. Desiccant - activated alumina, silica gel, anhydrous calcium sulphate, molecular sieve, or any combination of these i
5、n molded or granular form. B. Shell - copper, brass, or steel. C. Strainer corrosion proof strainers suitable to retain the type of desiccant used. 3. Strength: Conforn to UL standard UL207. 4. Dehydhators shall be of a non-refillable type for use with refirgerant conforming to A-A-58060. 5. Dimensi
6、on “A” may be attained on shorter units by use of an adaptor or extension supplied with the unit and having the same type end connection. 6. Finish: The shell, when steel, shall be corrosion-resistant treated outside. 7. The shell when fabricated of steel shall be brazed, silver soldered, or welded.
7、 When brass or copper shall be brazed or silver soldered. 8. Maximum shell diameters are not intended to preclude dehydrators having welded beads around the circumference of the shell in excess of diameters shown. Provided by IHSNot for ResaleNo reproduction or networking permitted without license f
8、rom IHS-,-,-MS35845F 3 NOTES: 1. Dimension are in inches. 2. For design feature purposes this standard takes precedence over procurement documents referenced herein. 3. Referenced documents shall be the issue in effect on the date of invitation for bids or request for proposal. 4. Changes from previ
9、ous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of changes. Custodians: Preparing activity: Army GL DLA - IS Navy - SH Air Force - 99 (Project 4130-2010-003) Review activity: Army CR4 NOTE: The activities listed abo
10、ve were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-