DLA SMD-5962-09226 REV B-2011 MICROCIRCUIT HYBRID RS485 INTERFACE TRANSCEIVER DUAL CHANNEL.pdf

上传人:inwarn120 文档编号:698445 上传时间:2019-01-02 格式:PDF 页数:15 大小:115.74KB
下载 相关 举报
DLA SMD-5962-09226 REV B-2011 MICROCIRCUIT HYBRID RS485 INTERFACE TRANSCEIVER DUAL CHANNEL.pdf_第1页
第1页 / 共15页
DLA SMD-5962-09226 REV B-2011 MICROCIRCUIT HYBRID RS485 INTERFACE TRANSCEIVER DUAL CHANNEL.pdf_第2页
第2页 / 共15页
DLA SMD-5962-09226 REV B-2011 MICROCIRCUIT HYBRID RS485 INTERFACE TRANSCEIVER DUAL CHANNEL.pdf_第3页
第3页 / 共15页
DLA SMD-5962-09226 REV B-2011 MICROCIRCUIT HYBRID RS485 INTERFACE TRANSCEIVER DUAL CHANNEL.pdf_第4页
第4页 / 共15页
DLA SMD-5962-09226 REV B-2011 MICROCIRCUIT HYBRID RS485 INTERFACE TRANSCEIVER DUAL CHANNEL.pdf_第5页
第5页 / 共15页
点击查看更多>>
资源描述

1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Table I; corrected the min limit for IOSfrom 70 mA to 50 mA. Table I; corrected the condition for RE$ $ $ $from 0 V to 5 V. Table I; corrected the max limit for tLZfrom 300 ns to 350 ns. Table I; corrected the max limit for tZHfrom 150 ns to 180

2、ns. Figure 4; In the RECEIVER function table remove the line that has DIFF input = -500 mV -100 mV L H -500 mV L L X H/OPEN H OPEN X H SHORT X H NOTE: X = Dont care. FIGURE 4. Function tables. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD

3、MICROCIRCUIT DRAWING SIZE A 5962-09226 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 11 DSCC FORM 2234 APR 97 FIGURE 5. Driver/Receiver timing test circuit, (channel 1 or 2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ST

4、ANDARD MICROCIRCUIT DRAWING SIZE A 5962-09226 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 12 DSCC FORM 2234 APR 97 FIGURE 6. Timing diagrams. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZ

5、E A 5962-09226 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 13 DSCC FORM 2234 APR 97 TABLE II. Electrical test requirements. MIL-PRF-38534 test requirements Subgroups (in accordance with MIL-PRF-38534, group A test table) Interim electrical parameters 1, 9 Final electrical

6、parameters 1*, 2, 3, 9, 10, 11 Group A test requirements 1, 2, 3, 9, 10, 11 Group C end-point electrical parameters 1, 2, 3, 9, 10, 11 End-point electrical parameters for Radiation Hardness Assurance (RHA) devices Not applicable * PDA applies to subgroup 1. 4.2 Screening. Screening shall be in accor

7、dance with MIL-PRF-38534. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to either DLA Land and Ma

8、ritime -VA or the acquiring activity upon request. Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TAas specified in accordance with table I of method 1015 of MIL-STD-88

9、3. b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. 4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (P

10、I) shall be in accordance with MIL-PRF-38534 and as specified herein. 4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows: a. Tests shall be as specified in table II herein. b. Subgroups 4, 5, 6, 7, and 8 shall be omitted. 4.3.2 Group B inspecti

11、on (PI). Group B inspection shall be in accordance with MIL-PRF-38534. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09226 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 14 DSCC FORM

12、 2234 APR 97 4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows: a. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circ

13、uit shall be maintained by the manufacturer under document revision level control and shall be made available to either DLA Land and Maritime -VA or the acquiring activity upon request. Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accorda

14、nce with the intent specified in method 1005 of MIL-STD-883. (2) TAas specified in accordance with table I of method 1005 of MIL-STD-883. (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. 4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with M

15、IL-PRF-38534. 4.3.5 Radiation Hardness Assurance (RHA) inspection. RHA inspection is not currently applicable to this drawing. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534. 6. NOTES 6.1 Intended use. Microcircuits conforming to thi

16、s drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing. 6.3 Con

17、figuration control of SMDs. All proposed changes to existing SMDs will be coordinated as specified in MIL-PRF-38534. 6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires configuration control and the applicable SMD. DLA Land and Mar

18、itime will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should contact DLA Land and Maritime -VA, telephone (614) 692-0544. 6.5 Comments. Comments on this drawing shou

19、ld be directed to DLA Land and Maritime -VA, Columbus, Ohio 43218-3990, or telephone (614) 692-1081. 6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors listed in MIL-HDBK-103 and QML-38534 have submitted a certificate of compliance (see 3.7 herein) to DLA

20、Land and Maritime -VA and have agreed to this drawing. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING BULLETIN DATE: 11-09-01 Approved sources of supply for SMD 5962-09226 are listed below for immediate acquisition info

21、rmation only and shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a certificate of compliance has been submitted to and accepted

22、by DLA Land and Maritime -VA. This information bulletin is superseded by the next dated revisions of MIL-HDBK-103 and QML-38534. DLA Land and Maritime maintains an online database of all current sources of supply at http:/www.landandmaritime.dla.mil/Programs/Smcr/. Standard microcircuit drawing PIN

23、1/ Vendor CAGE number Vendor similar PIN 2/ 5962-0922601KXA 88379 DRS4485-201-2S 5962-0922601KXC 88379 DRS4485-201-1S 1/ The lead finish shown for each PIN representing a hermetic package is the most readily available from the manufacturer listed for that part. If the desired lead finish is not list

24、ed contact the Vendor to determine its availability. 2/ Caution. Do not use this number for item acquisition. Items acquired to this number may not satisfy the performance requirements of this drawing. Vendor CAGE Vendor name number and address 88379 Aeroflex Plainview Incorporated, (Aeroflex Microe

25、lectronics Solutions) 35 South Service Road Plainview, NY 11803The information contained herein is disseminated for convenience only and the Government assumes no liability whatsoever for any inaccuracies in the information bulletin. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DL T 5113 1-2005 Quality degree evaluate standard of unit engineering for hydro power and water conservancy construction engineering Part 1 Civil department《水电水利基本建设工程 单元工程质量等级评定标准.pdf DL T 5113 1-2005 Quality degree evaluate standard of unit engineering for hydro power and water conservancy construction engineering Part 1 Civil department《水电水利基本建设工程 单元工程质量等级评定标准.pdf
  • DL T 5113 10-2012 9375 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 10 bituminous concrete engineering 《水.pdf DL T 5113 10-2012 9375 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 10 bituminous concrete engineering 《水.pdf
  • DL T 5113 3-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 3 Turbine and generator units installation .pdf DL T 5113 3-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 3 Turbine and generator units installation .pdf
  • DL T 5113 4-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 4 Auxiliary equipment of hydraulic machiner.pdf DL T 5113 4-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 4 Auxiliary equipment of hydraulic machiner.pdf
  • DL T 5113 5-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 5 Electric generation equipment installatio.pdf DL T 5113 5-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 5 Electric generation equipment installatio.pdf
  • DL T 5113 6-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 6 Step-up substation electrical equipment i.pdf DL T 5113 6-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering Part 6 Step-up substation electrical equipment i.pdf
  • DL T 5113 8-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering - Part 8 Hydraulic roller compacted concrete eng.pdf DL T 5113 8-2012 Quality degree evaluate standard of unit engineering for hydropower and water conservancy construction engineering - Part 8 Hydraulic roller compacted concrete eng.pdf
  • DL T 5117-2000 Test code on non-dispersible underwater concrete《水下不分散混凝土试验规程》.pdf DL T 5117-2000 Test code on non-dispersible underwater concrete《水下不分散混凝土试验规程》.pdf
  • DL T 5118-2010 Plan design guide for the rural electric power network《农村电力网规划设计导则》.pdf DL T 5118-2010 Plan design guide for the rural electric power network《农村电力网规划设计导则》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1