DLA SMD-5962-78007 REV E-2012 MICROCIRCUIT LINEAR GENERAL PURPOSE OPERATIONAL AMPLIFIER MONOLITHIC SILICON.pdf

上传人:outsidejudge265 文档编号:698608 上传时间:2019-01-02 格式:PDF 页数:8 大小:99.10KB
下载 相关 举报
DLA SMD-5962-78007 REV E-2012 MICROCIRCUIT LINEAR GENERAL PURPOSE OPERATIONAL AMPLIFIER MONOLITHIC SILICON.pdf_第1页
第1页 / 共8页
DLA SMD-5962-78007 REV E-2012 MICROCIRCUIT LINEAR GENERAL PURPOSE OPERATIONAL AMPLIFIER MONOLITHIC SILICON.pdf_第2页
第2页 / 共8页
DLA SMD-5962-78007 REV E-2012 MICROCIRCUIT LINEAR GENERAL PURPOSE OPERATIONAL AMPLIFIER MONOLITHIC SILICON.pdf_第3页
第3页 / 共8页
DLA SMD-5962-78007 REV E-2012 MICROCIRCUIT LINEAR GENERAL PURPOSE OPERATIONAL AMPLIFIER MONOLITHIC SILICON.pdf_第4页
第4页 / 共8页
DLA SMD-5962-78007 REV E-2012 MICROCIRCUIT LINEAR GENERAL PURPOSE OPERATIONAL AMPLIFIER MONOLITHIC SILICON.pdf_第5页
第5页 / 共8页
点击查看更多>>
资源描述

1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Correct errors Table I. Insert paragraph 6.2. 83-11-03 N. A. HAUCK B Table I, page 4, delete Input offset voltage / current temp sensitivity VIO/ T and IIO/ T. Page 5, Guarantee transit response overshoot TR(OS). 84-12-10 N. A. HAUCK C Make chang

2、es to table I, table II, figure 1, and paragraph 1.2.2. Change to military drawing format. Delete vendors CAGE 04713, 18324, 01295, and 07263. 88-12-19 M. A. FRYE D Make correction to the Open loop voltage gain test units column as specified under Table I. - ro 04-06-10 R. MONNIN E Update boilerplat

3、e to current MIL-PRF-38535 requirements. -rrp 12-02-06 C. SAFFLE NOT FOR NEW DESIGN FOR DLA LAND AND MARITIME USE ONLY CURRENT CAGE CODE 67268 THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED. REV SHEET REV SHEET REV STATUS REV E E E E E E E OF SHEETS SHEET 1 2 3 4 5 6 7 PMIC N/A PREPARED

4、BY JOAN M. FISHER DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil STANDARD MICROCIRCUIT DRAWING THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE CHECKED BY WILLIAM E. SHOUP APPROVED BY NELSON A. HAUCK MICROCIRCUIT, LINEA

5、R, GENERAL PURPOSE, OPERATIONAL AMPLIFIER, MONOLITHIC SILICON DRAWING APPROVAL DATE 78-07-05 AMSC N/A REVISION LEVEL E SIZE A CAGE CODE 14933 78007 SHEET 1 OF 7 DSCC FORM 2233 APR 97 5962-E187-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDA

6、RD MICROCIRCUIT DRAWING SIZE A 78007 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in accordance with MIL-PRF-38535, appendix

7、 A. 1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example: 78007 01 C A Drawing number Device type (see 1.2.1) Case outline (see 1.2.2) Lead finish (see 1.2.3) 1.2.1 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic

8、 number Circuit function 01 709 General purpose operational amplifier 1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style C GDIP1-T14 or CDIP2-T14 14 Dual-in-line G MACY1-X8 8 Can H GDFP1-F10 or CD

9、FP2-F10 10 Flat pack P GDIP1-T8 or CDIP2-T8 8 Dual-in-line 1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A. 1.3 Absolute maximum ratings. Supply voltage (VCC) . 18 V dc Input voltage (VIN) . 10 V dc Differential input voltage 5 V dc Maximum power dissipation (PD) 300

10、mW Storage temperature range -65C to +150C Lead temperature (soldering, 10 seconds) +300C Junction temperature (TJ) +150C 1.4 Recommended operating conditions. Supply voltage range (VCC) . 9 V dc to 15 V dc Ambient operating temperature range (TA) -55C to +125C 1.5 Power and thermal characteristics.

11、 Package Case outline Maximum allowable power dissipation Maximum JCMaximum JADual in line C, P 400 mW at TA= +125C 35C/W 120C/W 8-lead can G 330 mW at TA= +125C 40C/W 150C/W 10 lead FP H 330 mW at TA= +125C 60C/W 150C/W Provided by IHSNot for ResaleNo reproduction or networking permitted without li

12、cense from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 78007 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET 3 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a pa

13、rt of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STAND

14、ARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available

15、online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this dra

16、wing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B

17、devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-PRF-38535 may be processed as QML product in accordance with the man

18、ufacturers approved program plan and qualifying activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device. These modi

19、fications shall not affect the PIN as described herein. A “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 is required to identify when the QML flow option is used. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specif

20、ied in MIL-PRF-38535, appendix A and herein. 3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.2 herein. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the ele

21、ctrical performance characteristics are as specified in table I and shall apply over the full ambient operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are described in

22、table I. 3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devic

23、es built in compliance to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 to identify when the QML flow option is used. Provided by IHSNot for ResaleNo reproduction or networking permitted without licen

24、se from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 78007 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET 4 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions -55C TA +125C VCC= 15 V, VCM= 0, Group A subgroups Device type Limits Unit

25、 RS= 10 k unless otherwise specified Min Max Input offset voltage VIOVCC= 15 V, RS= 0 and 1 01 5.0 mV VCC= 9 V, RS= 10 k 2,3 6.0 Input offset current IIOVCC= 9 V and VCC= 15 V 1,2 01 -200 200 nA 3 -500 500 Input bias current IIBVCC= 9 V and VCC= 15 V 1,2 01 0.5 A 3 1.5 Power supply rejection ration

26、PSRR 9 V VCC 15 V 1,2,3 01 -150 150 V/V Input voltage common mode rejection CMR VCC= 15 V, -8 V VCM 8 V 1,2,3 01 70 dB Supply current ICCVCC= 15 V, RS= 0 1 01 5.5 mA 2 4.5 3 6.3 Output voltage swing (maximum) VOPVCC= 15 V, RL= 10 k, RS= 0 4,5,6 01 12 V VCC= 15 V, RL= 2 k, RS= 0 10 Open loop voltage

27、gain (single ended) AVS()VCC= 15 V, RL 2 k, VOUT= 10 V, RS= 0 4,5,6 01 25 70 V/mV Gain bandwidth GBW VCC= 15 V, VIN= 50 mV, RL= 2 k, TMS = 20 kHz, TA= +25C 4 01 250 kHz Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZ

28、E A 78007 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET 5 DSCC FORM 2234 APR 97 Device type 01 Case outlines C G H P Terminal number Terminal number 1 NC INPUT FREQ COMP B NC INPUT FREQ COMP B 2 NC INV INPUT INPUT FREQ COMP B INV INPUT 3 INPUT FREQ COMP B NON-INV INPUT INV I

29、NPUT NON-INV INPUT 4 INV INPUT VCC-NON-INV INPUT VCC-5 NON-INV INPUT OUTPUT FREQ COMP VCC-OUTPUT FREQ COMP 6 VCC-OUTPUT OUTPUT FREQ COMP OUTPUT 7 NC VCC+OUTPUT VCC+8 NC INPUT FREQ COMP A VCC+INPUT FREQ COMP A 9 OUTPUT FREQ COMP - INPUT FREQ COMP A - 10 OUTPUT - NC - 11 VCC+- - - 12 INPUT FREQ COMP A

30、 - - - 13 NC - - - 14 NC - - - NC = No connection FIGURE 1. Terminal connections. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 78007 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET 6 DSCC

31、 FORM 2234 APR 97 3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DLA Land and Maritime -VA prior to listing as an appro

32、ved source of supply shall affirm that the manufacturers product meets the requirements of MIL-PRF-38535, appendix A and the requirements herein. 3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits del

33、ivered to this drawing. 3.8 Notification of change. Notification of change to DLA Land and Maritime -VA shall be required for any change that affects this drawing. 3.9 Verification and review. DLA Land and Maritime, DLA Land and Maritimes agent, and the acquiring activity retain the option to review

34、 the manufacturers facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the reviewer. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535, appendix A. 4.2 Screenin

35、g. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be

36、maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 10

37、15 of MIL-STD-883. (2) TA= +125C, minimum. b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. 4.3 Quality conformance inspection. Quality conformance

38、inspection shall be in accordance with method 5005 of MIL-STD-883 including groups A, B, C, and D inspections. The following additional criteria shall apply. 4.3.1 Group A inspection. a. Tests shall be as specified in table II herein. b. Subgroups 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-S

39、TD-883 shall be omitted. 4.3.2 Groups C and D inspections. a. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test conditions, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under d

40、ocument revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. (2) TA= +125C, mini

41、mum. (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 78007 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET

42、7 DSCC FORM 2234 APR 97 TABLE II. Electrical test requirements. MIL-STD-883 test requirements Subgroups (in accordance with MIL-STD-883, method 5005, table I) Interim electrical parameters (method 5004) 1 Final electrical test parameters (method 5004) 1*, 2, 3, 4 Group A test requirements (method 50

43、05) 1, 2, 3, 4, 5, 6 Groups C and D end-point electrical parameters (method 5005) 1, 2, 3 * PDA applies to subgroup 1. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A. 6. NOTES 6.1 Intended use. Microcircuits conforming to

44、 this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing. 6.3

45、 Configuration control of SMDs. All proposed changes to existing SMDs will be coordinated with the users of record for the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal. 6.4 Record of users. Military and industrial users shall inform DLA

46、 Land and Maritime when a system application requires configuration control and the applicable SMD to that system. DLA Land and Maritime will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic

47、s devices (FSC 5962) should contact DLA Land and Maritime -VA, telephone (614) 692-0544. 6.5 Comments. Comments on this drawing should be directed to DLA Land and Maritime -VA, Columbus, Ohio 43218-3990, or telephone (614) 692-0540. 6.6 Approved sources of supply. Approved sources of supply are list

48、ed in MIL-HDBK-103. The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted by DLA Land and Maritime -VA. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING BULLETIN DATE: 12-02-06 Approved sources of supply for SMD 78007 are listed below for immediate acquisition information only and shall be added to