1、 EIA STANDARD TP-15B Contact Strength Test Procedure for Electrical Connectors EIA-364-15B (Revision of EIA-364-15A) June 2015 ANSI/EIA-364-15B-2015 Approved: June 5, 2015 EIA-364-15B NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misu

2、nderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect

3、 preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used either dome

4、stically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the St

5、andard or Publication. This standard is based upon the major technical content of International Electrotechnical Commission standard 60512-16-3 (was IEC 512-8, test 16c), Contact-bending strength, 2008. It conforms in all essential respects this IEC standard. This Standard does not purport to addres

6、s all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No

7、. 5349, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards. Published by Electronic Components Industry Association 2015 EIA Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE ! DONT VIOLATE THE LAW! This doc

8、ument is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1

9、-877-413-5186), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 2 Test resources 1 2.1 Test equipment 1 3 Test specimen 1 3.1 Description 1 3.2 Preparation 1 4 Test procedure . 2 4.1 Test load 2 4.2 Permanent set 2 5 Details to be specified . 2 6 Test documentati

10、on . 2 Figure 1 Mounting fixture . 3 ii (This page left blank) EIA-364-15B Page 1 TEST PROCEDURE No. 15B CONTACT STRENGTH TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS (From EIA Standards Proposal No. 5349, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards,

11、and previously published in EIA-364-15A.) 1 Introduction 1.1 Scope This standard establishes a test method to determine the pin contact strength for contact sizes 20 and smaller when subjected to a defined bending stress (or moment). 2 Test resources 2.1 Test equipment Test equipment shall consist o

12、f a displacement meter and a suitable means of positively securing the pin contact. 2.1.1 Displacement meter A displacement meter (i.e. dial indicator) having an accuracy of 5% shall be used to measure permanent set. 2.1.2 Mounting fixture A fixture that positively secures the pin contact, in the ar

13、ea indicated in figure 1, shall be used. 3 Test specimen 3.1 Description A test specimen shall consist of a pin contact, unless than otherwise specified in the referencing document. 3.2 Preparation The test specimen shall be secured in a suitable mounting fixture as indicated in figure 1, unless oth

14、erwise specified in the referencing document. EIA-364-15B Page 2 4 Test procedure 4.1 Test load The test load shall be applied as indicated in figure 1, with the rate of travel of the loading mechanism not exceeding 25.4 millimeters / minute (1.0 inch / minute). The load shall be maintained for 60 s

15、econds +15 seconds, -0 seconds. 4.2 Permanent set The permanent set shall be the difference between the initial position of the contact before the load is applied, and the final position of the contact after prescribed load has been removed. The degree of permanent set shall not exceed 0.13 millimet

16、ers (0.005 inch) at the 0.8 L load point unless otherwise specified in the referencing document. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Number of specimens to be tested 5.2 Test specimen description 5.3 Special preparations or conditioning

17、, if required 5.4 Minimum moment required per individual contact size, see figure 1 5.5 Duration of test load application, if other than specified in 4.1 5.6 Maximum permissible permanent set, if other than specified in 4.2 6 Test documentation Documentation shall contain the details specified in cl

18、ause 5, with any exceptions, and the following: 6.1 Title of test 6.2 Specimen description, including fixturing 6.3 Test equipment used, and date of last and next calibration 6.4 Test and procedure 6.5 Values and observations 6.6 Name of operator and start/finish date(s) of test EIA-364-15B Page 3 P

19、in size Moment 20 0.060 Newton meter (0.53 pound inch) 22 0.025 Newton meter (0.22 pound inch) 23 0.018 Newton meter (0.16 pound inch) 24 0.015 Newton meter (0.13 pound inch) NOTE 1) Load = Moment / 0.8L Figure 1 Mounting fixture ECIA Document Improvement Proposal If in the review or use of this doc

20、ument, a potential change is made evident for safety, health or technical reasons, please fill in the appropriate information below and mail or FAX to: Electronic Components Industry Association EIA Standards & Technology Department 2214 Rock Hill Rd., Suite 265 Herndon, VA 20170 FAX: (571-323-0245)

21、 Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immediate: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommended Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE O

22、NLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Revision History Revision letter Project number Publication date Additions, changes and deletions - SP-1436 March 1984 Initial published as EIA RS-364-15 A SP-5110 March 2006 B SP-5349 Revised paragraph 6.6 Revise Fi

23、gure 1 to change the 60 to 60 maximum to correct error. Maximum was eliminated in some published copies Revise Figure 1 to add units to the 0.127 (0.005) radius dimensions Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org