1、 EIA STANDARD TP-38D Cable Pull-Out Test Procedure for Electrical Connectors EIA-364-38D (Revision of EIA-364-38C) November 2014 ANSI/EIA-364-38D-2014 Approved: November 17, 2014 EIA-364-38D NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminati

2、ng misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any

3、respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used eith

4、er domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting

5、 the Standard or Publication. This standard is based upon the major technical content of International Electrotechnical Commission standard 60512-17-3 (was IEC 512-9, test 17c), Cable Clamp Resistance to Cable Pull (Tensile), 2010-06. It conforms in all essential respects this IEC standard. This Sta

6、ndard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its

7、use. (From Standards Proposal No. 5326.01-A, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components Industry Association 2014 EIA Standards see table 1 6.6 Values and observations 6.7 Name of operator and start/fin

8、ish date(s) of test EIA-364-38D Page A-1 Annex A Previous MIL-STD-1344 designations (Informative) This informative annex is provided as a cross reference to the designations previously contained in MIL-STD-1344, method 2009.1. Table A.1 Test condition designation EIA-364-38 designations MIL-STD-1344

9、, method 2009.1 designationsCondition A Condition B Condition B Condition C Condition C Condition D Condition D Condition E Condition E Condition A Revision History Revision letter Project number Publication date Additions, changes and deletions - SP-1091 December 27, 1972 Initially published in EIA

10、 RS-364-2 as TP-38 A SP-1688 April 1985 B SP-3987 July 1999 B SP-5134-A July 1999 Reaffirmed date March 31, 2006 C SP-5169 May 2008 D SP-5326.01-A Revised paragraph 1.3 to correct reference document title Revised rate of load application in paragraph 4.1.2 and 4.2.2.from a specific value to an appro

11、ximate value ECIA Document Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill in the appropriate information below and mail or FAX to: Electronic Components Industry Association EIA Standards & Techno

12、logy Department 2214 Rock Hill Rd., Suite 265 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immediate: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommended Changes: c. Reaso

13、n/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org