1、EIASTANDARDFixed Capacitors for Use in Electronic Equipment - Part 18: Sectional Specification - Fixed Aluminium Electrolytic Surface Mount Capacitors with Solid (MnO2) and Non-solid ElectrolyteEIA-60384-18 (IEC 60384-18:2016, IDT) October 2017 Electronic Components Industry Association ANSI/EIA-603
2、84-18-2017 Approved: October 5, 2017EIA-60384-18NOTICEEIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purcha
3、ser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor s
4、hall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute
5、(ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is identical (IDT) with the International Standard IEC Publication 60384-18:2016 Edition 3: Fixe
6、d Capacitors for Use in Electronic Equipment - Part 18: Sectional Specification - Fixed Aluminium Electrolytic Surface Mount Capacitors with Solid (MnO2) and Non-solid Electrolyte. This document is the EIA Standard EIA-60384-18-2017: Fixed Capacitors for Use in Electronic Equipment - Part 18: Sectio
7、nal Specification - Fixed Aluminium Electrolytic Surface Mount Capacitors with Solid (MnO2) and Non-solid Electrolyte.The text, figures and tables of IEC 60384-18:2016 are used in this Standard with the consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted mate
8、rial has been reproduced with permission from ANSI. The IEC Foreword and Introduction are not part of the requirements of this standard but are included for information purposes only. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory r
9、equirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5390.05, formulated under the cognizance of the Steering Committee for Pas
10、sive Electronic Components Standards (S-1).Published by Electronic Components Industry Association 2017 Engineering Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170PLEASE ! DONT VIOLATE THE LAW!This document is copyrighted by the ECIA and may not be reproduced without permission. Organiza
11、tions may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS Markit 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5186), International (303-397-7956) i CONTENTS FOREWORD iv1 General . 1
12、1.1 Scope . 11.2 Object . 11.3 Normative references 11.4 Information to be given in a detail specification 21.4.1 General . 21.4.2 Outline drawing and dimensions . 21.4.3 Mounting 21.4.4 Ratings and characteristics 21.4.5 Marking . 31.5 Terms and definitions 31.6 Marking . 31.6.1 General . 31.6.2 In
13、formation for marking 31.6.3 Marking on capacitors 31.6.4 Marking on packaging 42 Preferred ratings and characteristics 42.1 Preferred characteristics 42.2 Preferred values of ratings 42.2.1 Nominal capacitance (CN) 42.2.2 Tolerance on nominal capacitance 42.2.3 Rated voltage (UR) 42.2.4 Category vo
14、ltage (UC) 42.2.5 Surge voltage. 52.2.6 Rated temperature . 53 Quality assessment procedures 53.1 Primary stage of manufacture 53.2 Structurally similar components . 53.3 Certified test records of released lots . 53.4 Qualification approval procedures 53.4.1 General . 53.4.2 Qualification approval o
15、n the basis of the fixed sample size procedure 53.4.3 Tests . 63.5 Quality conformance inspection . 163.5.1 Formation of inspection lots 163.5.2 Test schedule 163.5.3 Delayed delivery 163.5.4 Assessment levels . 164 Test and measurement procedures 174.1 Drying . 174.2 Measuring conditions . 184.3 Mo
16、unting . 184.3.1 General . 184.3.2 Initial inspections . 184.3.3 Test conditions . 18ii 4.3.4 Final inspections 184.4 Visual examination and check of dimensions 184.4.1 General . 184.4.2 Visual examination and check of dimensions 184.4.3 Requirements 184.5 Electrical tests . 184.5.1 Leakage current
17、. 184.5.2 Capacitance . 194.5.3 Tangent of loss angle (tan ) or equivalent series resistance (ESR) 194.5.4 Impedance (if required) 204.6 Resistance to soldering heat 204.6.1 General . 204.6.2 Test conditions . 204.6.3 Recovery . 204.6.4 Final inspections and requirements 204.7 Solderability 204.7.1
18、General . 204.7.2 Test conditions . 214.7.3 Final inspections and requirements 214.8 Shear test . 214.8.1 General . 214.8.2 Final inspections and requirements 214.9 Substrate bending test . 214.9.1 General . 214.9.2 Final inspections and requirements 214.10 Rapid change of temperature . 214.10.1 Gen
19、eral . 214.10.2 Initial inspections . 214.10.3 Test conditions . 214.10.4 Recovery . 214.10.5 Final inspections and requirements 214.11 Climatic sequence . 224.11.1 General . 224.11.2 Initial inspections . 224.11.3 Dry heat . 224.11.4 Damp heat, cyclic, Test Db, first cycle 224.11.5 Cold . 224.11.6
20、Damp heat, cyclic, Test Db, remaining cycles . 224.11.7 Recovery . 224.11.8 Final inspections and requirements 224.12 Damp heat, steady state 224.12.1 General . 224.12.2 Initial inspections . 224.12.3 Test conditions . 224.12.4 Recovery . 234.12.5 Final inspections and requirements 234.13 Characteri
21、stics at high and low temperature . 234.13.1 General . 23iii 4.13.2 Inspections and requirements . 234.14 Surge voltage 234.14.1 General . 234.14.2 Initial inspections . 234.14.3 Test conditions . 234.14.4 Recovery . 234.14.5 Final inspections and requirements 244.15 Endurance 244.15.1 General . 244
22、.15.2 Initial inspections . 244.15.3 Test conditions . 244.15.4 Recovery . 244.15.5 Final inspections and requirements 244.16 Reverse voltage (if required) . 244.16.1 Initial inspections . 244.16.2 Test conditions . 244.16.3 Recovery . 254.16.4 Final inspections and requirements 254.17 Storage at hi
23、gh temperature 254.17.1 General . 254.17.2 Initial inspections . 254.17.3 Test conditions . 254.17.4 Recovery . 254.17.5 Final inspections and requirements 254.18 Storage at low temperature (if required) . 254.18.1 General . 254.18.2 Initial inspections . 254.18.3 Test conditions . 254.18.4 Recovery
24、 . 254.18.5 Final inspections and requirements 254.19 Charge and discharge (if required) 264.19.1 General . 264.19.2 Initial inspections . 264.19.3 Test conditions . 264.19.4 Final inspections and requirements 264.20 Component solvent resistance (if required) 264.21 Solvent resistance of the marking
25、 (if required) . 264.22 High surge current (if required) 274.22.1 General . 274.22.2 Final inspections and requirements 27Table 1 Surge voltages . 5Table 2 Sampling plan for qualification approval, assessment level EZ 7Table 3 Test schedule for qualification approval (1 of 8) 8Table 4 Lot-by-lot ins
26、pection . 17Table 5 Periodic inspection . 17iv INTERNATIONAL ELECTROTECHNICAL COMMISSION _ FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part 18: Sectional specification Fixed aluminium electrolytic surface mount capacitors with solid (MnO2) and non-solid electrolyte FOREWORD 1) The International
27、 Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fi
28、elds. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any I
29、EC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardiza
30、tion (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has represen
31、tation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC ca
32、nnot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publicati
33、ons. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, a
34、ccess to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including i
35、ndividual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance up
36、on, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements
37、 of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 60384-18 has been prepared by IEC technical committee 40: Capacitors and resistors for electronic equipment. This third edition ca
38、ncels and replaces the second edition published in 2007 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Revision of the structure in accordance with ISO/IEC Directives, Part 2:2011 (sixth edition) to the
39、 extent practicable, and harmonization between other similar kinds of documents. v b) In addition, Clause 4 and all the tables have been reviewed in order to prevent duplications and contradictions. The text of this standard is based on the following documents: FDIS Report on voting 40/2460/FDIS 40/
40、2466/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. The list of all parts of the IEC 60384 series, under the general title Fix
41、ed capacitors for use inelectronic equipment, can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC website under “http:/webstore.iec.ch“ in the data related to the specific publication. At
42、 this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. EIA-60384-18 Page 1 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part 18: Sectional specification Fixed aluminium electrolytic surface mount capacitors with solid (MnO2) and non-solid electroly
43、te 1 General 1.1 Scope This part of IEC 60384 applies to fixed aluminium electrolytic surface mount capacitors with solid (MnO2) and non-solid electrolyte primarily intended for d.c. applications for use in electronic equipment. These capacitors are primarily intended for use in electronic equipment
44、 to be mounted directly on substrates for hybrid circuits or to printed boards. Capacitors for special-purpose applications may need additional requirements. 1.2 Object The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropria
45、te quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance level, becaus
46、e lower performance levels are not permitted. 1.3 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition
47、 of the referenced document (including any amendments) applies. IEC 60063, Preferred number series for resistors and capacitors IEC 60068-1:2013, Environmental testing Part 1: General and guidance IEC 60068-2-58:2015, Environmental testing Part 2-58: Tests Test Td: Test methods for solderability, re
48、sistance to dissolution of metallization and to soldering heat of surface mounting devices (SMD) IEC 60384-1:2016, Fixed capacitors for use in electronic equipment Part 1: Generic specification IEC 60417, Graphical symbols for use on equipment IEC 61193-2:2007, Quality assessment system Part 2: Sele
49、ction and use of sampling plans for inspection of electronic components and packages ISO 3, Preferred numbers Series of preferred numbers EIA-60384-18 Page 2 1.4 Information to be given in a detail specification 1.4.1 General Detail specifications shall be derived from the blank detail specification. Detail specifications shall not specify requirements inferior to those of the generic, sectional or blank detail specification. When more severe requirements are included, they shall be listed in 1.9 of the detail specification and indicated i