EN 12390-5-2009 en Testing hardened concrete - Part 5 Flexural strength of test specimens《硬化混凝土试验 第5部分 试样的弯曲强度》.pdf

上传人:livefirmly316 文档编号:706235 上传时间:2019-01-03 格式:PDF 页数:14 大小:651.77KB
下载 相关 举报
EN 12390-5-2009 en Testing hardened concrete - Part 5 Flexural strength of test specimens《硬化混凝土试验 第5部分 试样的弯曲强度》.pdf_第1页
第1页 / 共14页
EN 12390-5-2009 en Testing hardened concrete - Part 5 Flexural strength of test specimens《硬化混凝土试验 第5部分 试样的弯曲强度》.pdf_第2页
第2页 / 共14页
EN 12390-5-2009 en Testing hardened concrete - Part 5 Flexural strength of test specimens《硬化混凝土试验 第5部分 试样的弯曲强度》.pdf_第3页
第3页 / 共14页
EN 12390-5-2009 en Testing hardened concrete - Part 5 Flexural strength of test specimens《硬化混凝土试验 第5部分 试样的弯曲强度》.pdf_第4页
第4页 / 共14页
EN 12390-5-2009 en Testing hardened concrete - Part 5 Flexural strength of test specimens《硬化混凝土试验 第5部分 试样的弯曲强度》.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、BS EN12390-5:2009ICS 91.100.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDTesting hardenedconcretePart 5: Flexural strength of testspecimensThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 May 2009 BSI

2、2009ISBN 978 0 580 58798 6Amendments/corrigenda issued since publicationDate CommentsBS EN 12390-5:2009National forewordThis British Standard is the UK implementation of EN 12390-5:2009. Itsupersedes BS EN 12390-5:2000 and which is withdrawn.The UK participation in its preparation was entrusted to T

3、echnicalCommittee B/517/1, Concrete production and testing.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compli

4、ance with a British Standard cannot confer immunityfrom legal obligations.BS EN 12390-5:2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 12390-5February 2009ICS 91.100.30 Supersedes EN 12390-5:2000 English VersionTesting hardened concrete - Part 5: Flexural strength of testspecimensEssai pour b

5、ton durci - Partie 5: Rsistance la flexionsur prouvettesPrfung von Festbeton - Teil 5: Biegezugfestigkeit vonProbekrpernThis European Standard was approved by CEN on 27 December 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving t

6、his EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (

7、English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgari

8、a, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIO

9、NCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12390-5:2009: EBS EN 12390-5:2009EN 12390-5:2009 (E) 2 Contents Pa

10、ge Foreword 3 1 Scope 5 2 Normative references 5 3 Principle 5 4 Apparatus .5 5 Test specimens 6 6 Procedures .6 7 Expression of results 7 8 Test report 7 9 Precision .8 Annex A (normative) Loading by a centre-point load . 10 BS EN 12390-5:2009EN 12390-5:2009 (E) 3 Foreword This document (EN 12390-5

11、:2009) has been prepared by Technical Committee CEN/TC 104 “Concrete and related products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2009, an

12、d conflicting national standards shall be withdrawn at the latest by August 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This

13、 document supersedes EN 12390-5:2000. It is recognized good practice to include measurement of density prior to the determination of flexural strength, as a check on compaction of the concrete. The two-point method of loading has been taken as the reference method, but the use of centre-point loadin

14、g has been included as a normative annex. An inter-comparison of the two-point and the centre-point methods has been made as part of a test programme, part-funded by the EC under the Measurement and Testing Programme, contract MAT I-CT-94-CO43. The centre-point method gave results which were consist

15、ently 13 % higher than those from the two-point method. This standard is one of a series concerned with testing concrete. The series EN 12390 includes the following parts: EN 12390 Testing hardened concrete Part 1: Shape, dimensions and other requirements for specimens and moulds; Part 2: Making and

16、 curing specimens for strength tests; Part 3: Compressive strength of test specimens; Part 4: Compressive strength - Specification for testing machines; Part 5: Flexural strength of test specimens; Part 6: Tensile splitting strength of test specimens; Part 7: Density of hardened concrete; Part 8: De

17、pth of penetration of water under pressure. The following amendments have been made to the 2000-10 edition of this standard: editorial revision selected loading rate to be applied after the initial (not exceeding approx 20% of the anticipated failure load) According to the CEN/CENELEC Internal Regul

18、ations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, BS EN 12390-5:2009EN 12390-5:2009 (

19、E) 4 Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 12390-5:2009EN 12390-5:2009 (E) 5 1 Scope This European Standard specifies a method for the determination of the flexural strength of specim

20、ens of hardened concrete. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

21、EN 12350-1, Testing fresh concrete Part 1: Sampling EN 12390-1:2000, Testing hardened concrete Part 1: Shape, dimensions and other requirements for test specimens and moulds EN 12390-2, Testing hardened concrete Part 2: Making and curing specimens for strength tests EN 12390-4, Testing hardened conc

22、rete Part 4: Compressive strength Specification for testing machines 3 Principle Prismatic specimens are subject to a bending moment by the application of load through upper and lower rollers. The maximum load sustained is recorded and the flexural strength is calculated. 4 Apparatus 4.1 Testing mac

23、hine The test shall be carried out using a testing machine conforming to EN 12390-4. 4.2 Force application The device for applying loads (see Figure 1) shall consist of: 1) two supporting rollers; 2) two upper rollers carried by an articulated cross member, which divides the load applied by the mach

24、ine equally between the two rollers. All rollers shall be manufactured from steel and shall have a circular cross-section with a diameter of 20 mm to 40 mm. They shall be at least 10 mm longer than the width of the test specimen. Three rollers, including the two upper ones, shall be capable of rotat

25、ing freely around their axis and of being inclined in a plane normal to the longitudinal axis of the test specimen. The distance, I, between the outer rollers (i.e. the span) shall be equal to 3d, where d is the width of the specimen. The distance between the inner rollers shall be equal to d. The i

26、nner rollers shall be equally spaced between the outer rollers as shown in Figure 1. All rollers shall be adjusted to the positions illustrated in Figure 1 to an accuracy of 2,0 mm. BS EN 12390-5:2009EN 12390-5:2009 (E) 6 5 Test specimens 5.1 General The test specimens shall be prisms conforming to

27、EN 12390-1. Specimens cast in moulds shall conform to EN 12350-1 and EN 12390-2. The direction of casting shall be identified on the specimen. Sawn specimens which meet the requirements of EN 12390-1 may also be tested. The specimens shall be examined and any abnormalities observed shall be reported

28、. 5.2 Adjustment of test specimens Where the dimensions or shapes of test specimens do not conform to 4.4 of EN 12390-1:2000 because they exceed the respective tolerances, they shall be rejected or adjusted as follows: 1) uneven surfaces shall be levelled by grinding; 2) the deviation of angles shal

29、l be corrected by cutting and/or grinding. 6 Procedures 6.1 Preparation and positioning of specimens Wipe clean all testing machine bearing surfaces and remove any loose grit or other extraneous material from the surfaces of the specimen that will be in contact with the rollers. For specimens stored

30、 in water, wipe excess moisture from the surface of the specimen before placing in the testing machine. Place the test specimen in the machine, correctly centred and with the longitudinal axis of the specimen at right angles to the longitudinal axis of the upper and lower rollers. Ensure that the re

31、ference direction of loading is perpendicular to the direction of casting of the specimen. NOTE The test result may be affected by the direction of loading with respect to the direction of casting. 6.2 Loading Do not apply the load until all loading and supporting rollers are resting evenly against

32、the test specimen. Select a constant rate of stress within the range 0,04 MPa/s (N/mm.s) to 0,06 MPa/s (N/mm.s). After the application of the initial load, which does not exceed approximately 20% of the failure load, apply the load to the specimen without shock and increase continuously, at the sele

33、cted constant rate 1 0 %, until no greater load can be sustained. The required loading rate is given by the formula: IddsR221= (1) where: R is the required loading rate, in N/s; BS EN 12390-5:2009EN 12390-5:2009 (E) 7 s is the stress rate, in MPa/s (N/mm.s); d1and d2are the lateral dimensions of the

34、 specimen, in mm; I is the spacing of the lower rollers, in mm. When using manually controlled testing machines, correct, by appropriate adjustment of the controls, any tendency for the selected rate of loading to decrease, as specimen failure is approached. Record the maximum load indicated. Report

35、 a fracture if it is outside the loading rollers. (see Figure 1). 7 Expression of results The flexural strength is given by the equation: cf 212F Ifdd=(2) where fcfis the flexural strength, in MPa (N/mm); F is the maximum load, in N; I is the distance between the supporting rollers, in mm; d1and d2a

36、re the lateral dimensions of the specimen, in mm (see Figure 1). Express the flexural strength to the nearest 0,1 MPa (N/mm). 8 Test report The report shall include: a) identification of the test specimen; b) designated or measured dimensions of the specimen; c) details of adjustment by grinding (if

37、 appropriate); d) type of apparatus: two point/centre point; e) surface moisture condition of specimen at time of test (saturated/moist); f) date of test; g) maximum load at failure, in kN; h) flexural strength of specimen, to nearest 0,1 MPa (N/mm); i) location of fracture (if outside upper rollers

38、); j) appearance of the concrete (if unusual); BS EN 12390-5:2009EN 12390-5:2009 (E) 8 k) any deviation from the standard test method; l) a declaration from the person technically responsible for the test that it was carried out in accordance with this document, except as detailed in item k). The re

39、port may include: m) condition of specimen on receipt for storage; n) age of specimen at time of test (if known); o) appearance of the concrete (if unusual). 9 Precision There is currently no precision data for this test, or the alternative test set out in Annex A. Key 1 Loading roller (capable of r

40、otation and of being inclined) 2 Supporting roller 3 Supporting roller (capable of rotation and of being inclined) Figure 1 Arrangement of loading of test specimen (two-point loading) BS EN 12390-5:2009EN 12390-5:2009 (E) 9 Key 1 Loading roller (capable of rotation and of being inclined) 2 Supportin

41、g roller 3 Supporting roller (capable of rotation and of being inclined) Figure 2 Arrangement of loading of test specimen (centre-point loading) BS EN 12390-5:2009EN 12390-5:2009 (E) 10 Annex A (normative) Loading by a centre-point load A.1 General In the case where a centre-point load is used, the

42、method of test shall be changed in accordance with this Annex. NOTE This method gives higher values for the flexural strength than the two-point method. An inter-comparison undertaken in the EC Measurement and Testing Programme, under contract MAT 1-CT-94-0043, indicates that the centre-point loadin

43、g method gives results consistently 13 % higher than the two-point loading method. A.2 Force application The loading arrangements shall consist of one load-applying roller at mid-span as indicated in Figure 2. The load-applying roller shall be free to rotate. A.3 Loading application The load shall b

44、e applied in accordance with 6.2, except that the loading rate shall be determined in accordance with the formula: IsddR=32221(A.1) where: R is the required loading rate, in MPa (N/mm) s is the stress rate, in MPa/s (N/mm.s); d1and d2are the lateral dimensions of the specimen, in mm. (see Figure 2)

45、I is the spacing of the lower rollers, in mm. A.4 Expression of results The flexural strength is given by the equation: cf 21232F Ifdd=(A.2) where fcfis the flexural strength, in MPa (N/mm); BS EN 12390-5:2009EN 12390-5:2009 (E) 11 F is the maximum load, in N; I is the distance between the supportin

46、g rollers, in mm; d1and d2are the lateral dimensions of the cross-section, in mm. Express the flexural strength to the nearest 0,1 MPa (N/mm). A.5 Test report In the test report clearly indicate that the centre-point loading method was used. BS EN12390-5:2009BSI GroupHeadquarters 389Chiswick High Ro

47、ad,London, W4 4AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 - British Standards InstitutionBSI is the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in Europe and at theinternational level. It is incorporated by Royal Charter.RevisionsB

48、ritish Standards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the constant aim of BSI to improve the quality of our products and services.We would be grateful if anyone finding an inaccuracy or ambiguity whi

49、le usingthis British Standard would inform the Secretary of the technical committeeresponsible, the identity of which can be found on the inside front cover. Tel:+44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensuresthat subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should beaddressed to Customer Services. Tel: