EN 3660-062-2016 en Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 062 Cable outlet style K 90 for heat shrinkabl.pdf

上传人:ideacase155 文档编号:711108 上传时间:2019-01-03 格式:PDF 页数:22 大小:1.16MB
下载 相关 举报
EN 3660-062-2016 en Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 062 Cable outlet style K 90 for heat shrinkabl.pdf_第1页
第1页 / 共22页
EN 3660-062-2016 en Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 062 Cable outlet style K 90 for heat shrinkabl.pdf_第2页
第2页 / 共22页
EN 3660-062-2016 en Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 062 Cable outlet style K 90 for heat shrinkabl.pdf_第3页
第3页 / 共22页
EN 3660-062-2016 en Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 062 Cable outlet style K 90 for heat shrinkabl.pdf_第4页
第4页 / 共22页
EN 3660-062-2016 en Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 062 Cable outlet style K 90 for heat shrinkabl.pdf_第5页
第5页 / 共22页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 3660-062:2016Aerospace series Cableoutlet accessories for circularand rectangular electrical andoptical connectorsPart 062: Cable outlet, style K, 90, forheat shrinkable boot, shielded, sealed, self-locking for EN 3645 Product standardBS EN 3660-062:2016 BRITISH STANDA

2、RDNational forewordThis British Standard is the UK implementation of EN 3660-062:2016.It supersedes BS EN 3660-062:2009 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations

3、 represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0

4、 580 89593 7ICS 49.060Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS

5、EN 3660-062:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 3660-062 January 2016 ICS 49.060 Supersedes EN 3660-062:2009English Version Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 062: Cable outlet, style K, 90, for heat

6、shrinkable boot, shielded, sealed, self-locking for EN 3645 - Product standard Srie arospatiale - Accessoires arrire pour connecteurs circulaires et rectangulaires lectriques et optiques - Partie 062 : Raccord, type K, coud 90, blind, tanche, pour manchon thermortractable, auto-frein pour EN 3645 -

7、Norme de produit Luft- und Raumfahrt - Endgehuse fr elektrische und optische Rund- und Rechtecksteckverbinder - Teil 062: Endgehuse, Bauform K, 90, fr wrmeschrumpfende Bauteile, Schirmanschlu, abgedichtet, selbstsichernd fr EN 3645 - Produktnor This European Standard was approved by CEN on 8 June 20

8、15. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained

9、on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CEN

10、ELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Ita

11、ly, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Aven

12、ue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 3660-062:2016 EBS EN 3660-062:2016EN 3660-062:2016 (E) 2 Contents Page European foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definition

13、s . 5 4 Characteristics . 5 5 Tests . 11 6 Designation . 18 7 Marking . 18 8 Technical specification . 18 BS EN 3660-062:2016EN 3660-062:2016 (E) 3 European foreword This document (EN 3660-062:2016) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (AS

14、D-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this European Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be g

15、iven the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2016, and conflicting national standards shall be withdrawn at the latest by July 2016. Attention is drawn to the possibility that some of the elements of this document may be

16、the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 3660-062:2009. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to imp

17、lement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romani

18、a, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 3660-062:2016EN 3660-062:2016 (E) 4 1 Scope This European Standard defines a range of cable outlets, style K, 90, shielded, sealed, self-locking (anti-rotational), for heat shrinkable boot, and/ or metallic bands

19、 for use under the following conditions: The mating connectors are listed in EN 3660-002. NOTE Class N in EN 3660-001 cross refers to class F in EN 3660-062. Temperature range, Class F (N) : 65 C to 200 C (See note above); Class K : 65 C to 200 C; Class W : 65 C to 175 C; Class T : 65 C to 175 C (Ni

20、ckel PTFE plating); Class Z : 65 C to 175 C (Zinc Nickel plating). Associated electrical accessories : EN 3660-033 Metallic band (for shield termination). These cable outlets are designed for termination of overall shielding braid and / or individual cable shields. They accommodate/permit the termin

21、ation of heat shrinkable boots. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenc

22、ed document (including any amendments) applies. EN 2591- 1), Aerospace series Elements of electrical and optical connection Test methods EN 3645 (all parts), Connectors, electrical, circular, scoop-proof, triple start threaded coupling operating temperature 175 C or 200 C continuous EN 3660-001, Aer

23、ospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 001: Technical specification EN 3660-002, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 002: Index of product standards EN 3660-0

24、33, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 033: Stainless steel banding band, style Z, for attachment of individual and/or overall screens to cable outlets Product standard 2)EN 3909, Aerospace series Test fluids and test methods

25、 for electric components and sub-assemblies IEC 60529, Degrees of protection provided by enclosures (IP Code) DIN 82, Knurling 1) All its parts quoted in this European Standard. 2) In preparation at the date of publication of this European Standard. BS EN 3660-062:2016EN 3660-062:2016 (E) 5 3 Terms

26、and definitions For the purposes of this document, the terms and definitions given in EN 3660-001 apply. (Self-locking / anti-rotational definition) A self-locking or anti rotational mechanism provides a nut rotation with moderate torque in the mated direction and provides a greater torque in the un

27、mated direction. 4 Characteristics 4.1 Dimensions and mass For dimensions and mass, see Figure 1 and Table 1a), Table 1b) to Table 4. For cable entry dimensions, see 4.2. All dimensions are in millimetres. BS EN 3660-062:2016EN 3660-062:2016 (E) 6 Key 1 O-Ring 2 Thread C 3 Marking 4 Four tooling hol

28、es spaced 90 apart. 2,60, depth, 1,27 5 Straight knurl. Pitch manufacturers option. 6 Number of teeth N 7 RKV 08 DIN 82. Figure 2. (Please note there may be crossover dependent on diameter and pitch) 8 Minimum penetration of D from the front of serrations 9 Optional clearance feature, 0,60 max. dept

29、h 10 Break edge NOTE 1 Cable outlets may be manufactured as cast, fabricated or machined (manufactures option). NOTE 2 No sharp edges / burrs permissible on internal or external surfaces / joints. Surface finish of on all internal surfaces NOTE 3 Reference clearance feature (9) when nut is in the un

30、coupled position the nut shall not contact the shell body. NOTE 4 Valley of start of tooth to be at vertical centre line of accessory at position shown: within 3 for shell sizes 09-13; within 2 for shell sizes 15-19; within 1 for shell sizes 21 and larger. Figure 1 Cable outlet 1,6 m max. BS EN 3660

31、-062:2016EN 3660-062:2016 (E) 7 Table 1a) Fixed dimensions of shell Dimensions in millimetres Shell size A B C D E G H I J N max. max. Thread min. max. max. max. min. max. Number of teeth 09 21,79 15,24 M12 1,0-6H 6,7 16,76 14,85 10,2 2,9 31,05 12 11 24,99 18,21 M15 1,0-6H 9,9 16,76 16,60 13,7 2,9 3

32、4,21 16 13 29,39 21,18 M18 1,0-6H 12,8 16,76 18,15 16,8 2,9 37,95 20 15 32,49 25,14 M22 1,0-6H 16,0 16,76 19,50 17,9 2,9 39,65 24 17 35,71 28,12 M25 1,0-6H 19,2 16,76 21,10 21,2 2,9 41,25 28 19 38,50 31,09 M28 1,0-6H 21,4 16,76 22,10 23,2 2,9 43,75 32 21 41,70 34,04 M31 1,0-6H 24,6 16,76 23,60 26,2

33、2,9 46,91 36 23 44,91 36,90 M34 1,0-6H 27,7 16,76 25,20 29,4 2,9 50,10 40 25 47,98 39,88 M37 1,0-6H 30,9 16,76 26,90 32,6 1,7 53,26 44 Table 1b) Feature 9 dimensions (optional) Dimensions in millimetres Shell size Depth of flat K max. max. 09 0,60 11,20 11 0,60 12,80 13 0,60 15,00 15 0,60 16,55 17 0

34、,60 18,15 19 0,60 19,55 21 0,60 21,15 23 0,60 22,75 25 0,60 24,30 BS EN 3660-062:2016EN 3660-062:2016 (E) 8 Table 2 Mass for classes K, F (N), W, T and Z Nominal mass in grams Shell size code Cable entry size code Classes A B C D E F G H J K L M 09 13,3 13,6 F (N), T, W, Z 33,8 34,4 K 11 15,9 16,5 1

35、7,2 17,9 F (N), T, W, Z 40,0 41,9 43,6 45,5 K 13 19,4 19,8 20,2 21,1 21,7 22,2 F (N), T, W, Z 48,8 49,9 51,0 53,3 54,8 56,2 K 15 23,9 24,3 24,7 25,1 25,9 26,5 27,7 F (N), T, W, Z 58,8 59,9 61,0 62,0 64,3 66,0 69,1 K 17 28,1 28,6 29,0 29,3 29,6 29,9 31,7 32,7 F (N), T, W, Z 69,5 70,6 71,7 72,6 73,3 7

36、4,1 78,9 81,7 K 19 30,9 31,3 31,7 32,0 32,3 32,6 33,7 35,3 F (N), T, W, Z 77,5 78,6 79,7 80,6 81,3 82,1 85,2 89,2 K 21 38,0 38,4 38,8 39,1 39,4 39,7 40,3 41,7 42,7 F (N), T, W, Z 94,1 95,3 96,3 97,3 98,0 98,8 100,3 104,1 106,6 K 23 41,9 42,3 42,7 43,1 43,3 43,7 44,2 44,6 45,8 47,0 F (N), T, W, Z 104

37、,9 106,0 107,1 108,0 108,7 109,6 111,1 112,1 115,2 118,2 K 25 51,1 51,5 51,9 52,3 52,6 52,9 53,5 53,8 54,6 55,2 56,6 F (N), T, W, Z 125,8 126,9 128,0 129,0 129,6 130,5 132,0 133,0 135,0 136,5 140,3 K BS EN 3660-062:2016EN 3660-062:2016 (E) 9 4.2 Cable entry dimensions See Figure 2, Table 3. Figure 2

38、 Cable entry Table 3 Dimensions in millimetres Cable entry size code A B C D Bundle diameter 0,1 0,1 0,3 + 0,2 0 min. max. A 4,7 7,7 12,2 1,12 2,0 4,0 B 6,4 9,4 14,0 1,12 3,9 5,5 C 7,9 11,0 15,5 1,12 5,4 7,5 D 9,5 12,6 17,1 1,12 7,4 9,0 E 11,1 14,1 18,7 1,12 9,4 10,5 F 12,7 15,7 20,3 1,12 10,4 12,0

39、G 15,9 18,9 23,5 1,12 12,4 15,5 H 19,1 22,0 26,7 1,12 15,4 18,5 J 22,2 25,2 29,8 1,75 18,4 21,5 K 25,5 28,4 33,0 1,75 21,4 25,0 L 28,6 31,5 36,2 1,75 25,4 28,0 M 31,8 34,7 39,4 1,75 28,4 31,0 NOTE The cable entry shall be selected in accordance with the maximum diameter of the cable bundle. BS EN 36

40、60-062:2016EN 3660-062:2016 (E) 10 4.3 Associated connectors See EN 3660-002. 4.4 Standard front interface See Figure 3 and Table 4. All dimensions are in millimetres. Detail A Key 1 See detail A Figure 3 Interface Table 4 Dimensions in millimetres Shell size A B Ref. min. 09 10,57 7,5 11 13,56 10,8

41、 13 16,58 13,8 15 20,57 16,9 17 23,57 20,1 19 26,57 22,8 21 29,57 26,0 23 32,56 29,1 25 35,56 32,3 BS EN 3660-062:2016EN 3660-062:2016 (E) 11 4.5 Material and finish NOTE Class N in EN 3660-001 cross refers to class F in EN 3660-062. Material/Finish Class F (N) : Aluminium/Nickel plated (see note ab

42、ove) Material/Finish Class K : Stainless steel/Passivated Material/Finish Class W : Aluminium/Olive drab cadmium plated Material Finish Class T : Aluminium (Nickel PTFE plated) Material/ Finish Class Z : Aluminium (Zinc Nickel plated) 4.6 Assembly torque These torque values are intended for installa

43、tion use only, see Table 5. Table 5 Shell size Assembly torque 0,56 Nm Class K Classes F (N), T, W and Z 09 6,33 4,52 11 8,59 4,52 13 12,2 4,52 15 13,1 4,52 17 13,1 4,52 19 13,1 4,52 21 15,4 9,04 23 15,4 9,04 25 15,4 9,04 5 Tests 5.1 Tests according to EN 2591-100 Test details to be in accordance wi

44、th Table 6, EN 3660-001 and EN 2591-100. Qualification to be in accordance with EN 3660-001. BS EN 3660-062:2016EN 3660-062:2016 (E) 12 Table 6 EN 2591- Designation of the test Not applicable Applicable see EN 3660-001 Details 101 Visual examination X 102 Examination of dimensions and mass X See 4.1

45、 and 4.2. 205 Housing (shell) electrical continuity X Cable outlet connector connection. Class F (N): 2,5 m Class W: 5 m Class K: 10 m Class T: 5 m Class Z: 5 m 212 Surface transfer impedance (from 100 MHz to 1 GHz) aX Frequency Zt (m) MHz Class F (N) Classes W, T, Z Class K 0,1 5 10 20 1 5 10 20 10

46、 7 15 30 30 10 20 40 100 20 40 80 Test mounting as per Figure 4 and as specified in 5.2. The Zt values correspond to the total surface impedance of the assembly. Test shall be achieved with a same size and class couple connectors EN 3645 (all parts) than the accessory. Use Table 5 values for the ass

47、embly. 212 Shielding effectiveness from 100 MHz to 1 GHz X Use Table 5 values for the assembly. Frequency Minimum attenuation Classes F (N), T, W and Z Class K MHz dB dB 100 90 80 BS EN 3660-062:2016EN 3660-062:2016 (E) 13 EN 2591- Designation of the test Not applicable Applicable see EN 3660-001 De

48、tails 200 88 75 300 88 83 400 87 71 800 85 66 1 000 85 65 214 Lightning strike, current and voltage pulse X Current pulse All classes Level D (10 kA Waveform 2) Use Table 5 values for the assembly. Refer to EN 3660-001 for detail of mounting method. Housing shell continuity values to be measured between the receptacle flange and heat shrink boot lip groove on the accessory. It is acceptable for visual appearance to be affected where it is as a direct result of the test application. After conditioning housing shell continuity values may increase 100 % fro