EN 81-58-2003 en Safety rules for the construction and installation of lifts - Examination and tests - Part 58 Landing doors fire resistance test (Remains Current)《电梯建造和安装的安全规则 检验和.pdf

上传人:boatfragile160 文档编号:712791 上传时间:2019-01-03 格式:PDF 页数:32 大小:406.07KB
下载 相关 举报
EN 81-58-2003 en Safety rules for the construction and installation of lifts - Examination and tests - Part 58 Landing doors fire resistance test (Remains Current)《电梯建造和安装的安全规则 检验和.pdf_第1页
第1页 / 共32页
EN 81-58-2003 en Safety rules for the construction and installation of lifts - Examination and tests - Part 58 Landing doors fire resistance test (Remains Current)《电梯建造和安装的安全规则 检验和.pdf_第2页
第2页 / 共32页
EN 81-58-2003 en Safety rules for the construction and installation of lifts - Examination and tests - Part 58 Landing doors fire resistance test (Remains Current)《电梯建造和安装的安全规则 检验和.pdf_第3页
第3页 / 共32页
EN 81-58-2003 en Safety rules for the construction and installation of lifts - Examination and tests - Part 58 Landing doors fire resistance test (Remains Current)《电梯建造和安装的安全规则 检验和.pdf_第4页
第4页 / 共32页
EN 81-58-2003 en Safety rules for the construction and installation of lifts - Examination and tests - Part 58 Landing doors fire resistance test (Remains Current)《电梯建造和安装的安全规则 检验和.pdf_第5页
第5页 / 共32页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 81-58:2003 Safety rules for the construction and installation of lifts Examination and tests Part 58: Landing doors fire resistance test The European Standard EN 81-58:2003 has the status of a British Standard ICS 91.140.90 BS EN 81-58:2003 This British Standard, was published

2、 under the authority of the Standards Policy and Strategy Committee on 28 July 2003 BSI 28 July 2003 ISBN 0 580 42354 9 National foreword This British Standard is the official English language version of EN 81-58:2003. The UK participation in its preparation was entrusted to Technical Committee MHE/

3、4, Lift, hoists and escalators, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found

4、in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are respons

5、ible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the

6、 UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 29 and a back cover. The BSI copyright notice displayed in this document indicat

7、es when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN8158 July2003 ICS91.140.90 Englishversion Safetyrulesfortheconstructionandinstallationoflifts ExaminationandtestsPart58:Landingdoorsfireresistance test Rgl

8、esdescuritpourlaconstructionetlinstallationdes lvateursExamenetessaisPartie58:Essaisde rsistanceaufeudesportespalires SicherheitsregelnfrdieKonstruktionunddenEinbauvon AufzgenberprfungundPrfverfahrenTeil58: PrfungderFeuerwiderstandsfhigkeitvon Fahrschachttren ThisEuropeanStandardwasapprovedbyCENon18

9、March2003. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheManagementCent

10、reortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheManagementCentrehasthesamestatusasthe official versions. CENmembersarethenationalstandardsbodi

11、esofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal,Slovakia,Spain,Sweden,SwitzerlandandUn ited Kingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG Managem

12、entCentre:ruedeStassart,36B1050Brussels 2003CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN8158:2003EEN8158:2003(E) 2 Contents Foreword4 Introduction .5 1 Scope 6 2 Normativereferences 6 3 Termsanddefinitions. .6 4 Testprinciple 7 5 Testequipment 7

13、 6 Testconditions . .7 7 Testspecimen . .8 7.1 Construction.8 7.2 Numberofspecimens . 8 7.3 Sizeofspecimen 8 7.4 Installationofspecimen 8 8 Supportingconstruction . 8 9 Conditioning.8 10 Pretestexamination. .8 10.1 General8 10.2 Constructionaldetails . 9 10.3 Clearancegapmeasurementsanddepthofpenetr

14、ation 9 10.4 Functionalitytest . 13 11 Testinstrumentation . 14 11.1 Furnacethermocouples 14 11.2 FurnaceCO 2 concentration. .14 11.3 Gasflowmeasuringsysteminstrumentation .14 11.4 Furnacepressure. 14 11.5 Unexposedfacetemperature. .14 11.6 Radiationmeasurement 15 11.7 Deformationmeasurement .15 11.

15、8 Flowmeasurementverification 16 12 Testprocedure . 16 13 Testtermination . 16 14 Assessmentofperformance .16 15 Criteriaofperformance .17 15.1 Integrity(E) .17 15.2 Thermalinsulation(I). 17 15.3 Radiation(W) 17 16 Directfieldofapplication 17 17 Classificationprocedureanddeclarationofperformance 18

16、17.1 Performancecriteria . .18 17.2 Classificationperiods. .18 17.3 Designatoryletters 18 17.4 Declarationofperformance . .18 17.5 Classes18 18 Testreport 19 AnnexA (normative) Descriptionofthecanopyandmeasuringsystem20EN8158:2003(E) 3 AnnexB (normative) Standardsupportingconstruction23 AnnexC (norm

17、ative) Verificationprocedureforleakageratemeasurement .24 AnnexD (normative) Calculationofleakagerate 25 D.1 CalculationofleakageratewhenmeasuringaccordingtoENISO51671withanorificeplate.25 D.2 Pressurecorrection: 26 D.3 Interpretingtheleakageratecurve. .27 AnnexZA (informative) RelationshipofthisEur

18、opeanDocumentwithECDirectives .28 Bibliography 29EN8158:2003(E) 4 Foreword ThisdocumentEN8158:2003hasbeenpreparedbyTechnicalCommitteeCEN/TC10“Lifts,escalatorsand movingwalks”,thesecretariatofwhichisheldbyAFNOR. ThisEuropeanStandardshallbegiventhestatusofanationalstandard,eitherbypublicationofanident

19、icaltextor byendorsement,atthelatestby January2004,andconflictingnationalstandardsshallbewithdrawnatthelatest by January2004 . ThisdocumenthasbeenpreparedunderamandategiventoCENbytheEuropeanCommissionandtheEuropean FreeTradeAssociation,andsupportsessentialrequirementsof EUDirective(s) . Forrelations

20、hipwithEUDirective (s),seeinformativeAnnexZ A, whichisanintegralpartofthisdocument. AnnexesAtoDarenormative. AccordingtotheCEN/CENELECInternalRegulations,thenationalstandardsorganizationsofthefollowing countriesareboundtoimplementthisEuropeanStandard:Austria,Belgium,CzechRepublic,Denmark,Finland, Fr

21、ance,Germany,Greece,Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal, Slovakia,Spain,Sweden,SwitzerlandandtheUnitedKingdom.EN8158:2003(E) 5 Introduction ThisdocumentisatypeCstandardasstatedinEN1070. WhenprovisionsofthistypeCstandardaredifferentfromthosewhicharestatedintypeA

22、orBstandards,the provisionsofthistypeCstandardtakeprecedenceovertheprovisionsoftheotherstandardsforliftlandingdoors thathavebeendesignedandbuiltaccordingtotheprovisionsofthistypeCstandard. EN81hasidentifiedtheneedforcertainliftdoorstoactasfirebarriersagainstthetransferofafireviatheliftwell. ThisEuro

23、peanStandardspecifiesaprocedureforthispurpose.ItfollowsthegeneralprincipleofEN13631,Fire resistancetestsPart1:Generalrequirements,andwhereappropriatetheprocedureofEN16341,Fire resistancetestsfordoorandshutterassembliesPart1:Firedoorsandshutters.Additionallyatracergas techniqueforestablishingtheinteg

24、rityofaliftlandingdoorisused. LiftlandingdoorsarenotincludedinthescopeofEN16341. Liftlandingdoors,withadditionalapplications,thatmayalreadyhavebeentestedforotherthanpassengerlift landingdoorusetoEN16341,areconsideredtosatisfythecorrespondingclassificationaccordingtothis Europeanstandard.EN8158:2003(

25、E) 6 1Scope ThisEuropeanStandardspecifiesthemethodoftestfordeterminingthefireresistanceofliftlandingdoorswhich maybeexposedtoafirefromthelandingside.Theprocedureappliestoalltypesofliftlandingdoorsusedasa meansofaccesstoliftsinbuildingsandwhichareintendedtoprovideafirebarriertothespreadoffireviatheli

26、ft well. Theprocedureallowsforthemeasurementofintegrityandifrequiredthemeasurementofradiationandthermal insulation. Norequirementsotherthantheverificationthatthespecimenisoperational,areincludedformechanical conditioningbeforethetestastheseareincludedintherelevantproductstandard. 2 Normativereferenc

27、es ThisEuropeanStandardincorporatesbydatedorundatedreference,provisionsfromotherpublications.These normativereferencesarecitedattheappropriateplacesinthetextandthepublicationsarelistedhereafter.For datedreferences,subsequentamendmentstoorrevisionsofanyofthesepublicationsapplytothisEuropean Standardo

28、nlywhenincorporatedinitbyamendmentorrevision.Forundatedreferencesthelatesteditionofthe publicationreferredtoapplies(includingamendments). EN811, SafetyrulesfortheconstructionandinstallationofliftsPart1:Electriclifts . EN812, SafetyrulesfortheconstructionandinstallationofliftsPart2:Hydrauliclifts . E

29、N1070:1998, SafetyofmachineryTerminology EN13631:1999, FireresistancetestsPart1:Generalrequirements . EN13632, FireresistancetestsPart2:Alternativeandadditionalprocedures . EN16341, FireresistancetestsfordoorandshutterassembliesPart1:Firedoorsandshutters. ENISO51671, Measurementoffluidflowbymeansofp

30、ressuredifferentialdevicesinsertedincircularcross sectionconduitsrunningfullPart1:Generalprinciplesandrequirements (ISO51671:2003) ISO5221, AirdistributionandairdiffusionRulestomethodsofmeasuringairflowratesinanairhandlingduct. ISO9705, FiretestsFullscaleroomtestforsurfaceproducts . 3 Termsanddefini

31、tions ForthepurposesofthisEuropeanStandard,thetermsanddefinitionsgiveninEN1070:1998andinEN1363 1:1999apply. Additionaldefinitionsspecificallyneededforthisdocumentareaddedbelow: 3.1 liftlandingdoor doordesignedtobeinstalledintheliftwellopeningonalandingtoprovideaccesstothelift 3.2 thermallyuninsulate

32、dliftlandingdoor liftlandingdoorwhichisnotintendedtosatisfytheinsulationcriteriaofEN13631and15.2ofthisstandard. NOTE MostliftlandingdoorsfallinthiscategoryEN8158:2003(E) 7 3.3 thermallyinsulatedliftlandingdoor liftlandingdoorwhichisintendedtosatisfytheinsulationcriteriaofEN13631and15.2ofthisstandard

33、 3.4 dooropening widthoftheclearopeningallowingfreepassagethroughtheopenliftlandingdoor 3.5 doorassembly completeassembly,includinganyframeorguide,doorleaforleaves,whichisprovidedforaccesstoandfromthe liftandthelanding.Itincludesallpanels,hardware,sealingmaterialsandanyoperatingcomponents 3.6 suppor

34、tingconstruction constructionprovidedintheopeningofthetestframeorthefurnacefrontinordertoaccommodatethetest specimen 3.7 leakagerate totalflowrateofhotgasespassingthroughopeningsandgapsofthedoorassembly,duetooverpressureonthe landingside 4 Testprinciple 4.1 EN16341containsaprocedureforthedeterminati

35、onoffireresistanceofdoorswhichmaybeexposedtoa fireinabuildingfromeithersideandarerequiredtopreventthetransferoffirefromonesidetotheother.Lift landingdoorsrepresentaspecialuseofdoorswherethefireexposureisexpectedtobefromaspecifieddirection, i.e.thelandingside,andwherethehazardexistsonlysubsequenttoth

36、eentryofafireintotheliftwell.Suchadoor isgenerallynotdesignedtopossessthesameresistancetothepassageofhotgasesasadoorseparating adjacentspacesonthesamefloor. 4.2 Thetestconsistsofexposingthelandingsideofaliftlandingdoortotheheatingconditionsspecifiedin EN13631fortheperiodforwhichthedoorhastobeassesse

37、dforitsfireresistance.Duringthetest,positive pressureexistsoverthewholeheightofthedoorontheexposedside,inducingtheleakageoffurnacegasestothe unheatedside.Acanopyisprovidedontheunexposedsidewhichcollectstheleakedgasesandasuctionfan drawsthesethroughaductprovidedwithasystemformeasuringthevolumeflow(se

38、eannexA).The concentrationofCO 2 ,usedasatracergas,ismeasuredinthefurnaceandattheairflowmeasuringpoint,andby monitoringthegasflowrateanditstemperatureitispossibletocalculatetheleakagerateofhotgasesthroughthe testdoor.Themethodgivesarecordofthehotgasleakageasafunctionoftimewhichiscorrectedfornormal c

39、onditions.Thisprovidesabasisforassessingtheabilityofthedoortoactasaneffectivefirebarrier. 5 Testequipment 5.1 ThetestfurnaceshallbeasdescribedinEN13631. 5.2 ThecanopyshallbeasspecifiedinannexA. 5.3 ThemeasuringsystemforleakagerateshallbeasspecifiedinannexA. 6Test conditions 6.1 Thefurnaceshallbecont

40、rolledtofollowthetemperature/timecurveasspecifiedinEN13631. 6.2 Thefurnaceshallmaintainpositivepressureontheexposedsideoverthewholeheightofthespecimen suchthatthepressureatsilllevelisintherangeof(22)Pa. NOTE Itisfoundthatthepressuregradientovertheheightofthespecimenisaround8,5pascalspermeterheight.E

41、N8158:2003(E) 8 7 Testspecimen 7.1Construction Thetestspecimenshallbefullyrepresentativeofthedoorassemblyonwhichinformationisrequired. 7.2Numberofspecimens Asinformationisrequiredwhenthedoorisexposedtoheatingfromthelandingsideonly,onespecimenistested. Asecondspecimenmayberequiredaccordingto10.2tover

42、ifythedoorconstruction. 7.3Sizeofspecimen Thespecimenshallbefullsizeorthemaximumsizethatcanbeaccommodatedinthefurnace.Thetypicalsizeof thefrontopeningofthefurnaceis3m 3m.Inordertoexposearequiredminimumwidthof200mmofsupporting constructionforatypical3m 3mfurnace,theopeninginthesupportingconstructioni

43、srestrictedto2,6m 2,8 m(widthxheight). 7.4Installationofspecimen Thespecimenshallbemountedinasupportingconstructionhavingadequatefireresistance.Thesupporting constructionshallbebuiltfirstwithinthetestframeleavinganapertureofthespecifiedsize.Thewidthofthe supportingconstructiononthetwoverticalsidesandthetopshallbenotlessthan200mm. Thedesignoftheconnectionbetweenthedoorandthesupportingconstruction,includinganymaterialsusedto makethejunction,shallbeas

展开阅读全文
相关资源
猜你喜欢
  • ASHRAE 4668-2004 Results of a Residential Proton Exchange Membrane (PEM) Fuel Cell Demonstration at a Military Facility in New York《在纽约举行 一个军事设施住宅质子交换膜(质子交换膜)燃料电池示范的结果》.pdf ASHRAE 4668-2004 Results of a Residential Proton Exchange Membrane (PEM) Fuel Cell Demonstration at a Military Facility in New York《在纽约举行 一个军事设施住宅质子交换膜(质子交换膜)燃料电池示范的结果》.pdf
  • ASHRAE 4669-2004 Thermal Analysis of Solar-Powered Continuous Adsorption Air-Conditioning System《太阳能空调系统的热结构分析》.pdf ASHRAE 4669-2004 Thermal Analysis of Solar-Powered Continuous Adsorption Air-Conditioning System《太阳能空调系统的热结构分析》.pdf
  • ASHRAE 4670-2004 A Comparative Study of Shell-Side Condensation on Integral-Fin Tubes with R-114 and R-236a《壳侧凝结积分翅片管与R-114和R-114的比较研究》.pdf ASHRAE 4670-2004 A Comparative Study of Shell-Side Condensation on Integral-Fin Tubes with R-114 and R-236a《壳侧凝结积分翅片管与R-114和R-114的比较研究》.pdf
  • ASHRAE 4671-2004 A Comparative Study of the Airside Performance of Winglet Vortex Generator and Wavy Fin-and-Tube Heat Exchangers《小翼涡发生器和波纹翅片管式换热器 在机场禁区内的表现比较研究》.pdf ASHRAE 4671-2004 A Comparative Study of the Airside Performance of Winglet Vortex Generator and Wavy Fin-and-Tube Heat Exchangers《小翼涡发生器和波纹翅片管式换热器 在机场禁区内的表现比较研究》.pdf
  • ASHRAE 4672-2004 A Modified Model to Predict Air Infiltration into Refrigerated Facilities through Doorways《预测空气透过门口渗透到冷藏设施的改进的模型》.pdf ASHRAE 4672-2004 A Modified Model to Predict Air Infiltration into Refrigerated Facilities through Doorways《预测空气透过门口渗透到冷藏设施的改进的模型》.pdf
  • ASHRAE 4673-2004 A Switched Reluctance Motor in a Variable-Speed Pumping Application《在变速泵应用中的开关磁阻电机》.pdf ASHRAE 4673-2004 A Switched Reluctance Motor in a Variable-Speed Pumping Application《在变速泵应用中的开关磁阻电机》.pdf
  • ASHRAE 4674-2004 An Algorithm of Stereoscopic Particle Image Velocimetry for Full-Scale Room Airflow Studies《全尺寸室内气流研究用 立体粒子图像测速仪的运算法则》.pdf ASHRAE 4674-2004 An Algorithm of Stereoscopic Particle Image Velocimetry for Full-Scale Room Airflow Studies《全尺寸室内气流研究用 立体粒子图像测速仪的运算法则》.pdf
  • ASHRAE 4675-2004 Average Modified Stanton Number for Evaluating the Ice-Melting Characteristics of Ice Harvested from a Thermal Storage Tank《为评价收割热储罐中冰雪的融化特点 平均改性斯坦顿人数》.pdf ASHRAE 4675-2004 Average Modified Stanton Number for Evaluating the Ice-Melting Characteristics of Ice Harvested from a Thermal Storage Tank《为评价收割热储罐中冰雪的融化特点 平均改性斯坦顿人数》.pdf
  • ASHRAE 4676-2004 Comparsion of Diffusion Characteristics of Aersol Particles in Different Ventilated Rooms by Numercial Method《通过数值方法 在不同的通风设备的室内 比较气溶胶粒子的扩散特征》.pdf ASHRAE 4676-2004 Comparsion of Diffusion Characteristics of Aersol Particles in Different Ventilated Rooms by Numercial Method《通过数值方法 在不同的通风设备的室内 比较气溶胶粒子的扩散特征》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1