1、BSI Standards PublicationPressure regulators, automatic change-over devices, having a maximum regulated pressure of 4 bar, with a maximum capacity of 150 kg/h, associated safety devices and adaptors for butane, propane, and their mixturesBS EN 16129:2013National forewordThis British Standard is the
2、UK implementation of EN 16129:2013. It supersedes BS EN 12864:2001+A3:2009, BS EN 13785:2005+A1:2008 and BS EN 13786:2004+A1:2008 which will be withdrawn on 31 December 2015.The UK participation in its preparation was entrusted to Technical Committee GSE/24, Dedicated LPG appliances.A list of organi
3、zations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013Published by BSI Standards Limited 2013
4、ISBN 978 0 580 71605 8 ICS 23.060.40 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2013.Amendments/corrigenda issued since publicationDate Text affec
5、tedBRITISH STANDARDBS EN 16129:2013EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16129 June 2013 ICS 23.060.40 Supersedes EN 12864:2001, EN 13785:2005+A1:2008, EN 13786:2004+A1:2008English Version Pressure regulators, automatic change-over devices, having a maximum regulated pressure of 4 bar
6、, with a maximum capacity of 150 kg/h, associated safety devices and adaptors for butane, propane, and their mixtures Dtendeurs, inverseurs automatiques, ayant une pression maximum de dtente de 4 bar, avec une capacit maximale de 150 kg/h, dispositifs de scurit associs et adaptateurs pour butane, pr
7、opane et leurs mlanges Druckregelgerte, automatische Umschaltanlagen mit einem hchstem Ausgangsdruck bis einschlielich 4 bar und einem maximalen Durchfluss von 150 kg/h sowie die dazugehrigen Sicherheitseinrichtungen und bergangsstcke fr Butan, Propan und deren GemischeThis European Standard was app
8、roved by CEN on 9 March 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
9、standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language a
10、nd notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hung
11、ary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Manageme
12、nt Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16129:2013: EBS EN 16129:2013EN 16129:2013 (E) 2 Contents Page Foreword . 7 1 Scope 8 2 Normative references . 8 3 Terms and definiti
13、ons 10 3.1 General terms and definitions . 10 3.2 Terms and definitions concerning gas 12 3.3 Terms and definitions concerning pressures . 13 3.4 Terms and definitions concerning flow rates . 14 4 Types of regulating devices 14 4.1 Introduction 14 4.2 Regulating device with a nominal regulated press
14、ure specified by EN 437 15 4.3 Other regulating devices 15 5 Constructional characteristics 15 5.1 General . 15 5.2 Materials . 16 5.3 Special requirements . 17 5.3.1 Pressure sensing subassembly (regulating devices only) 17 5.3.2 Regulation subassembly (regulating devices only) . 17 5.3.3 Back pres
15、sure subassembly (regulating devices only) . 17 5.3.4 Connection subassembly 18 5.3.5 Change over devices . 20 5.4 Mechanical strength . 21 5.4.1 Resistance to impact . 21 5.4.2 Resistance to pressure 21 5.4.3 Strength of connections 21 5.5 Soundness 24 5.6 Mechanical endurance . 24 5.6.1 Regulators
16、 24 5.6.2 Automatic change over devices 25 5.6.3 Devices fitted with a manual closing device . 25 5.6.4 Quick coupling device . 25 5.6.5 Device with freely rotating outlet connection . 25 5.7 Resistance to humidity changes . 25 5.8 Resistance to corrosion . 25 6 Performance characteristics 26 6.1 Ge
17、neral . 26 6.2 Regulators 26 6.2.1 Supply and regulated pressures for regulators to be used on installations where the final pressure is to EN 437 . 26 6.2.2 Supply and regulated pressures for fixed or adjustable regulators to be used on installations where the final pressure is not to EN 437 . 30 6
18、.2.3 Variable regulators . 31 6.3 Automatic change over devices 32 6.3.1 Supply and regulated pressures for automatic change over devices to be used on installations where the final pressure is to EN 437 32 6.3.2 Supply and regulated pressures for fixed or adjustable automatic change over devices to
19、 be used on installations where the final pressure is not to EN 437 33 6.3.3 Automatic change over device with integral variable regulator . 34 6.3.4 Change over pressure 34 6.4 Adaptors . 34 BS EN 16129:2013EN 16129:2013 (E) 3 7 Test methods . 35 7.1 General conditions 35 7.1.1 Type of test gas . 3
20、5 7.1.2 Test conditions 35 7.1.3 Equivalence formulas 35 7.1.4 Test samples 36 7.2 Verification of constructional characteristics 36 7.2.1 Resistance to impact . 36 7.2.2 Resistance to pressure 36 7.2.3 Mechanical strength of connections. 37 7.2.4 Valve pad retention 42 7.2.5 Soundness . 42 7.2.6 Me
21、chanical endurance. 43 7.2.7 Resistance to humidity changes . 45 7.2.8 Resistance to corrosion 45 7.3 Verification of performance characteristics . 45 7.3.1 General . 45 7.3.2 Plotting of the performance curves for regulating devices . 48 7.3.3 Performances of adaptors . 49 7.3.4 Verification of fir
22、st stage pressure for G.56 connection regulating devices 49 7.3.5 Soundness of the non return valve . 50 8 Marking, packaging, instructions 50 8.1 General . 50 8.2 Marking of the device 50 8.3 Packaging 51 8.4 Instructions for installation, use and maintenance 51 Annex A (normative) Special requirem
23、ents for devices fitted with pressure or flow rate operated safety functions . 53 A.1 Regulating devices fitted with an over-pressure relief valve of a limited flow rate (PRV) 53 A.1.1 Definition 53 A.1.2 Constructional characteristics 53 A.1.3 Performance characteristics . 53 A.1.4 Test methods . 5
24、4 A.1.5 Regulating device marking 54 A.1.6 Instructions 54 A.2 Regulating devices fitted with an over-pressure shut off safety device (OPSO) 55 A.2.1 Definition 55 A.2.2 Constructional characteristics 55 A.2.3 Performance characteristics . 55 A.2.4 Test methods . 56 A.2.5 Regulating device marking 5
25、7 A.2.6 Instructions 57 A.3 Regulating devices fitted with an under-pressure shut off safety device (UPSO) 57 A.3.1 Definition 57 A.3.2 Constructional and performance characteristics . 57 A.3.3 Test methods . 57 A.3.4 Regulating device marking 58 A.3.5 Instructions 58 A.4 Regulating devices fitted w
26、ith an excess flow valve (EFV) 58 A.4.1 Definition 58 A.4.2 Performance characteristics . 58 A.4.3 Test methods . 59 A.4.4 Regulating device marking 62 A.4.5 Instructions 62 A.5 Regulating devices fitted with a regulated outlet pressure limiter 63 A.5.1 Definition 63 A.5.2 Constructional and perform
27、ance characteristics . 63 A.5.3 Test method . 63 BS EN 16129:2013EN 16129:2013 (E) 4 A.5.4 Marking . 64 A.5.5 Instructions 64 A.6 Two stage pressure limiting regulating device . 65 A.6.1 Description . 65 A.6.2 Constructional and performance characteristics . 65 A.6.3 Test methods 65 A.6.4 Marking .
28、65 A.6.5 Instructions 65 A.7 Additional diaphragm. 66 A.7.1 Description . 66 A.7.2 Constructional and performance characteristics . 66 A.7.3 Performance characteristics 66 A.7.4 Test methods 66 A.7.5 Marking . 66 A.7.6 Instructions 67 Annex B (normative) Special requirements for devices fitted with
29、a thermal shut off system . 68 B.1 Thermal shut off valve . 68 B.1.1 Definition 68 B.1.2 Constructional characteristics 68 B.1.3 Performance characteristics 68 B.1.4 Test methods 68 B.1.5 Marking . 69 B.1.6 Instructions 69 B.2 Thermal spindle on devices for self closing valve connection 69 B.2.1 Def
30、inition 69 B.2.2 Constructional characteristics 69 B.2.3 Performance characteristics 69 B.2.4 Test methods 70 B.2.5 Marking . 70 B.2.6 Instructions 70 Annex C (normative) Special requirements for devices under extreme temperature conditions (temperatures below -20 C) 71 C.1 Scope 71 C.2 Requirements
31、 . 71 C.2.1 Material . 71 C.2.2 Extreme temperature test 71 C.3 Conditioning . 71 C.4 Marking . 71 C.5 Instructions 71 Annex D (normative) Regulating devices for gas cylinders to supply appliances installed in caravans, motor caravans or freshwater boats . 72 D.1 Scope 72 D.2 Installations and conne
32、ctions . 72 D.3 Pressures and flow rate . 74 D.4 Pressure safety functions 75 D.5 Automatic change over system (“kit“) 75 D.6 Resistance to vibration 76 D.7 Marking . 76 D.8 Instructions 77 Annex E (normative) Complementary test requirements for non-metallic thermoplastic or thermal setting material
33、s used in the construction of devices . 78 E.1 Scope 78 E.2 Materials . 78 E.3 Special requirements . 79 E.3.1 Accelerated ageing 79 E.3.2 Resistance to hydrocarbons 80 E.3.3 Resistance to cracking under stress and when chemical agents are present 80 BS EN 16129:2013EN 16129:2013 (E) 5 E.3.4 Charact
34、eristics relating to fire resistance 80 E.4 Special conditions for carrying out the tests mentioned in the body of the standard . 80 E.4.1 Resistance to impact (see 5.4.1 and 7.2.1) . 80 E.4.2 Mechanical resistance of connections (see 5.4.3 and 7.2.3) 80 E.4.3 Soundness (see 5.5 and 7.2.5) 81 E.5 Sa
35、mpling and order of tests 81 Annex F (normative) Requirements for elastomeric reinforced diaphragms. 82 Annex G (normative) Inlet connections . 83 Annex H (normative) Outlet connections 98 Annex I (informative) Test method for resistance to corrosion 119 I.1 Principle . 119 I.2 Reagents 119 I.2.1 Sa
36、line solution . 119 I.2.2 Compressed air 119 I.2.3 Salt mist . 119 I.3 Apparatus . 120 I.4 Test method . 121 I.4.1 Method of exposure of devices . 121 I.4.2 Duration of tests 121 I.4.3 Checks . 121 I.4.4 Cleaning of devices . 122 I.5 Results . 122 Annex J (informative) Method for measuring leaks. 12
37、5 J.1 Scope . 125 J.2 Diagram of the test bench . 125 J.3 Coefficient K 126 J.3.1 Method . 126 J.3.2 Calculations . 126 J.4 Measurement of the leak . 126 J.4.1 Method . 126 J.4.2 Calculations . 126 J.5 Checks . 127 Annex K (normative) Special requirements for low pressure fixed regulators fitted wit
38、h two or three outlets for outdoor use 128 K.1 Scope . 128 K.2 Constructional characteristics 128 K.3 Performance characteristics . 128 K.4 Test methods . 128 K.4.1 Test on the shut off devices 128 K.4.2 Performance test . 129 K.5 Marking 130 K.6 Instructions 130 Annex L (normative) Special requirem
39、ents for regulators fitted with an inlet valve . 131 L.1 Scope . 131 L.2 Definition 131 L.3 Constructional characteristics 131 L.4 Performance characteristics : mechanical strength 131 L.5 Test methods . 131 Annex M (normative) Devices for gas cylinders to supply appliances installed in seawater boa
40、ts . 132 M.1 Scope . 132 M.2 General . 132 M.3 Maximum guaranteed flow rate . 132 M.4 Regulating devices fitted with a pressure relief valve . 132 M.5 Vent 132 M.6 Connections . 132 BS EN 16129:2013EN 16129:2013 (E) 6 M.7 Material . 132 M.8 Corrosion 132 M.8.1 General . 132 M.8.2 Corrosion requireme
41、nt . 133 M.8.3 Corrosion test method . 133 M.9 Marking . 133 M.10 Instructions for use and maintenance 133 Annex N (normative) Alternative possible seal . 134 N.1 Scope 134 N.2 Dimensions. 134 N.3 Materials . 134 N.4 Markings . 134 Annex ZA (informative) Relationship between this European Standard a
42、nd the Essential Requirements of EU Directive 2009/142/EC (for pressure regulators only) . 136 Bibliography 138 BS EN 16129:2013EN 16129:2013 (E) 7 Foreword This document (EN 16129:2013) has been prepared by Technical Committee CEN/TC 181 “Dedicated liquefied petroleum gas appliances”, the secretari
43、at of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2013, and conflicting national standards shall be withdrawn at the latest by December 2015. Attention is draw
44、n to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12864:2001, EN 13786:2004+A1:2008 and EN 13785:2005+A1:2008. This document
45、has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. The main technical c
46、hanges that have been made since the latest edition are as follows: the merging of EN 12864, EN 13785 and EN 13786 and their amendments; the extension of the scope to adaptors; the addition of requirements for taking into account pressure loses of gas installations; the removal from this standard of
47、 drawing of connections described in other standards; the improvement of testing methods; additional corrections. Change-over devices and adaptors within the scope of this standard, are not covered by the EU Directive for gas appliances (2009/142/EC). Items relating to quality assurance systems, pro
48、duction testing and particularly certificates of conformity are not covered in this standard. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus,
49、 Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 16129:2013EN 16129:2013 (E) 8 1 Scope This European Standard defines the constructional and operational characteristics, the safety requirements, test methods and the marking of regulators and automatic change-over devices having a maximum