EN 50117-2-2-2004 en Coaxial cables Part 2-2 Sectional specification for cables used in cabled distribution networks C Outdoor drop cables for systems operating at 5 MHz - 1000 MHz.pdf

上传人:cleanass300 文档编号:716669 上传时间:2019-01-04 格式:PDF 页数:16 大小:1.24MB
下载 相关 举报
EN 50117-2-2-2004 en Coaxial cables Part 2-2 Sectional specification for cables used in cabled distribution networks C Outdoor drop cables for systems operating at 5 MHz - 1000 MHz.pdf_第1页
第1页 / 共16页
EN 50117-2-2-2004 en Coaxial cables Part 2-2 Sectional specification for cables used in cabled distribution networks C Outdoor drop cables for systems operating at 5 MHz - 1000 MHz.pdf_第2页
第2页 / 共16页
EN 50117-2-2-2004 en Coaxial cables Part 2-2 Sectional specification for cables used in cabled distribution networks C Outdoor drop cables for systems operating at 5 MHz - 1000 MHz.pdf_第3页
第3页 / 共16页
EN 50117-2-2-2004 en Coaxial cables Part 2-2 Sectional specification for cables used in cabled distribution networks C Outdoor drop cables for systems operating at 5 MHz - 1000 MHz.pdf_第4页
第4页 / 共16页
EN 50117-2-2-2004 en Coaxial cables Part 2-2 Sectional specification for cables used in cabled distribution networks C Outdoor drop cables for systems operating at 5 MHz - 1000 MHz.pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 50117-2-2:2004+A2:2013Incorporating corrigendum June 2006Coaxial cables Part 2-2: Sectional specification for cables used in cabled distribution networks Outdoor drop cables for systems operating at 5 MHz 1 000 MHzICS 33.120.10nullnull nullnullnullnullnullnullnull nullnullnull

2、nullnullnullnull nullnullnull nullnullnullnullnullnullnullnullnullnull nullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnullnullNational forewordThis British Standard is the UK implementation of EN 50117-2-2:2004+A2:2013. It sup

3、ersedes BS EN 50117-2-2:2004+A1:2008, which is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment. For example, text altered by CENELEC amendment A1 is indicated

4、 by .The UK participation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained on request to its secretary.This p

5、ublication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 50117-2-2:2004+A2:2013This British Standard waspublished under the authorityof t

6、he Standards Policy andStrategy Committeeon 17 December 2004 The British Standards Institution 2013. Published by BSI Standards Limited 2013Amendments/corrigenda issued since publicationAmd. No. Date Comments 15859Corrigendum No. 130 June 2006 Revision of supersession details30 May 2008 Implementati

7、on of CENELECamendment A1:200830 September 2013 Implementation of CENELEC amendment A2:2013ISBN 978 0 580 77905 3EUROPEAN STANDARD EN 50117-2-2:2004+A2 NORME EUROPENNE EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Euro

8、pisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50117-2-2:2004 E ICS 33.120.10 English version Coaxial cables Part 2-2: S

9、ectional specification for cables used in cabled distribution networks Outdoor drop cables for systems operating at 5 MHz - 1 000 MHz Cbles coaxiaux Partie 2-2 : Spcification intermdiaire pour les cbles utiliss dans les rseaux de distribution cbls Cbles de raccordement usage extrieurpour des systmes

10、 fonctionnant 5 MHz -1 000 MHz Koaxialkabel Teil 2-2: Rahmenspezifikation fr Kabel frKabelverteilanlagen Aussenkabel im Bereich von 5 MHz - 1 000 MHz This European Standard was approved by CENELEC on 2004-09-01. CENELEC members arebound to comply with the CEN/CENELEC Internal Regulations which stipu

11、late the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standar

12、d exists in three official versions (English, French, German). A version in any otherlanguage made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national

13、electrotechnical committees ofAustria, Belgium, Cyprus, CzechRepublic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

14、 August 2013Foreword This European Standard wasprepared by SC46XA, Coaxial cab les, of Technical Committee CENELECTC 46X, Communication cables.The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50117-2-2 on 2004-09-01. The following dates were fixed: latest date

15、 by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2005-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow)2007-09-01 _ Forewor d to amendment A1This amendment to the Europ

16、ean Standard EN 50117-2-2:2004 was prepared by SC 46XA, Coaxialcables, of Technical Committee CENELEC TC 46X, Communication cables. The text of the draft was submitted to the Unique Acceptance Procedure andwas approved by CENELEC as amendment A1 to EN 50117-2-2:2004 on 2007-12-01. The following date

17、s were fixed: latest date by which the amendment has to be implementedat national level by publication of an identical national standard or by endorsement (dop) 2008-12-01 latest date by which the national standards conflictingwith the amendment have to be withdrawn (dow) 2010-12-01 _ Foreword to am

18、endment A2This document (EN 50117-2-2:2004/A2:2013) has been prepared by CLC/SC 46XA “Coaxial cables“ of CLC/TC 46X “Communication cables“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by

19、 endorsement (dop) 2014-07-01 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2016-07-01 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held re

20、sponsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). BS EN 50117-2-2:2004+A2:2013 EN 50117-2-2:2004+A2:2013 (E)Page 2Contents 1 Scope 4

21、2Normative references . 43Definitions. 44Requirements for cable construction.54.1 General.54.2 Inner conductor.54.3 Dielectric.54.4 Outer conductor or screen.54.5 Filling compounds54.6 Moisture barriers.54.7 Wrapping layers 54.8 Sheath.54.9 Metallic protection .64.10 Cable integral suspension strand

22、 (messenger wire)64.11 Oversheath64.12 Fauna proofing64.13 Chemical and/or environmental proofing64.14 Cable identification64.14.1 Sheath marking .64.14.2 Labelling65Tests for completed cables 75.1 Electrical tests.75.1.1 Low-frequency and D.C. electrical measurements75.1.2 High-frequency electrical

23、 and transmission measurements.85.2 Mechanical tests95.3 Environmental tests.115.4 Fire performance test methods .12Table 1 Low-frequency and D.C. electrical measurements7Table 2 High-frequency electrical and transmission measurements.8Table 3 Mechanical tests9Table 4 Environmental tests.11Table 6 D

24、rop cable types Nominal dimensions and ratings 12 6 Cable types.12Table deleted# $BS EN 50117-2-2:2004+A2:2013 EN 50117-2-2:2004+A2:2013 (E)Page 31 Scope This European Standard relates to EN 50117-1 and should be read in conjunction with this genericspecification. This specification applies to outdo

25、or drop cables foruse in cabled distribution systemsoperating at temperature between -40 C and +70 C 1) and at frequencies between 5 MHz and 1 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for

26、the electrical, mechanical, environmental and fire performance of the cables. 2 Normativereferences The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the refer

27、enced document (including any amendments) applies.EN 50083 series Cable networks for television signals, sound signals and interactive servicesEN 50117-1 Coaxial cables Part 1: Generic specification EN 50289-1-6 Communication cables Specifications for test methods Part 1-6: Electrical testmethods El

28、ectromagnetic performance EN 50289-3-9 Communication cables Specifications for test methods Part 3-9: Mechanical test methods Bending testsEN 50290-1-2 2) Communication cables Part 1-2: DefinitionsEN 50290-2-23 Communication cables Part 2-23: Common design rules and construction PE insulation EN 502

29、90-2-24 Communication cables Part 2-24: Common design rules and construction PE sheathing EN 50290-2-25 Communication cables Part 2-25: Common design rules and construction Polypropylene insulation compoundsEN 50290-2-27 Communication cables Part 2-27: Common design rules and construction Halogen fr

30、ee flame retardant thermoplastic sheathing compoundsEN 50290-4-1 Communication cables Part 4-1: General considerations for the use of cables Environmental conditions and safety aspectsEN 62153-1-1 Metallic telecommunication cable test methods Part 1-1: Electrical Measurement of the pulse/step return

31、 loss in the frequency domain using the Inverse Discrete Fourier Transformation (IDFT) (IEC 62153-1-1)IEC 61196-1-115 2) Coaxial communication cables Part 1-115: Electrical test methods Test forpulse return loss (regularity of impedance)3 Definitions For the purposes of this European Standard, the d

32、efinitions of EN 50290-1-2 and EN 50117-1 apply.1) This value is valid for applications without ampacity only.2) At draft stage.! The definition of a drop coaxial cable is one of use or intended use and application within the network rather than by specific constructional requirements of the cable i

33、tself. 3.1 drop cable coaxial cable which is used to connect from a) subscriber tap or a directional coupler to a system outlet, b) subscriber tap to a subscriber splitter, c) subscriber splitter to a system outlet“EN 50117-1:2002/A2:2013 Coaxial cables Part 1: Generic specification# $BS EN 50117-2-

34、2:2004+A2:2013 EN 50117-2-2:2004+A2:2013 (E)Page 44 Requirements for cable construction 4.1 General Designing the cable, consideration should be paid to the maximum admissible current stated in the detail specification. It is assumed that the raise of temperature of the inner conductor when submitte

35、d to the maximumcurrent under nominal ambient conditions does not affect the mechanical and electrical properties of the cable (details are under study).4.2 InnerconductorThe conductor shall meet the requirements of Subclause 4.2 of EN 50117-1, and shall be solid or tube. Individual wires can be pla

36、in or metal coated. Dimensions shall be in accordance with the detail specification. There shall be no joint made subsequent to the last drawing operation. 4.3 Dielectric The dielectric material(s) shall be in accordance with Subclause 4.3 of EN 50117-1 and shall consist ofpolyolefin materials,with

37、EN 50290-2-23 (polyethylene), EN 50290-2-25 (polypropylene) or any relevant part of EN 50290-2-XX. Dimensions shall be in accordance with the detail specification. Unlessotherwise specified, the nominal diameter over the dielectric should be one of the preferred values, namely 2,9 mm, 3,7 mm, 4,8 mm

38、 and 7,2 mm.4.4Outer conductor or screen The construction and material of the outer conductor and/or screen shall meet the requirements ofSubclause 4.4, items b), c), f) or g) of EN 50117-1. Where option b) is used, a double braid layer isrequired. Forbraid constructions or helically wound wires, th

39、e braid angle shall be between 15 and 45. The coverage factor shall be greater than or equal to 65 %, or, when the cable is provided with a metal foil, greater than or equal to 25 %. These values are also valid for cables with two bi-directional layers ofhelically wound wires.Dimensions shall be in

40、accordance with the detail specification. 4.5 Filling compounds Not applicable 4.6 Moisture barriers Not applicable 4.7 Wrapping layersNot applicable 4.8 SheathSheath material(s) shall meet the requirements of EN 50290-2-24 for PE sheaths or EN 50290-2-27 forhalogen free flame retardant materials.BS

41、 EN 50117-2-2:2004+A2:2013 EN 50117-2-2:2004+A2:2013 (E)Page 5Sheaths of cables used in aerial or external applications shall meet the requirement of the UV resistance test. The sheath shall also meet the requirements of Subclause 4.8 of EN 50117-1. Dimensions shall be in accordance with the detail

42、specification. 4.9 Metallic protection Not applicable 4.10 Cable integral suspension strand (messenger wire)When applicable messenger wires shall be in accordance with Subclause 4.10 of EN 50117-1. When applicable messenger wires shall meet the requirements of the relevant detail specification. 4.11

43、 OversheathNot applicable 4.12 Fauna proofing Not applicable 4.13 Chemical and/or environmental proofing Not applicable 4.14 Cable identificationCable identification shall be in accordance with Subclause 4.14 of EN 50117-1. 4.14.1 SheathmarkingSheath marking shall be achieved as a non-degradable pri

44、nt containing the following minimuminformation: designation of the cable; attenuation value (in dB/100 m at 800 MHz, rounded); screening class; Euro-class; name of supplier.EXAMPLEEN 50117-2-2 21 Class B Euro-class C 4.14.2 LabellingUnless otherwise specified in the detail specification drums or coi

45、ls shall be provided with a label with a non-degradable print containing the following minimum information: designation of the cable; attenuation value (in dB/100 m at 800 MHz, rounded); screening class; Euro-class; ! NOTE The Construction Products Directive (CPD) will define classes for the fire pe

46、rformance of cables. As long as theCPD is under consideration and fire performance classes (Euroclasses) are not defined, sheathmarking with Euroclass is not required.“BS EN 50117-2-2:2004+A2:2013 EN 50117-2-2:2004+A2:2013 (E)Page 6 name of supplier; batch part number; length of cable. EXAMPLEEN 501

47、17-2-2 21 Class B Euro-class C 03/04 543m5 Tests for completed cables When tested in accordance with the requirements of EN 50117-1, the requirements given below shall apply.5.1 Electrical tests 5.1.1 Low-frequency and D.C. electrical measurements Table 1 Low-frequency and D.C. electrical measuremen

48、ts EN 50117-1 Subclause nParameter Requirements/Remarks 5.1.1.1 Conductor resistance Applicable, value in accordance with the detail specification 5.1.1.2 Dielectric strength 2 kV D.C. or 1,5 kV A.C. for 1 min 5.1.1.3 Insulation resistance 10 4 M x km5.1.1.4 Mutual capacitance When required, in acco

49、rdance with the relevant detail specification 5.1.1.5 Voltage test of sheath 2,5 kV A.C. or 3,75 kV D.C., unless otherwise specified in the relevant detail specification. Test in accordance with EN 50289-1-X a5.1.1.6 Discharge (corona) testNot applicable 5.1.1.7 Voltage proof Not applicable 5.1.1.8 Power rating Not applicable a Test procedure is under consideration by CLC/SC 46XA.BS EN 50117-2-2:2004+A2:2013 EN 50117-2-2:2004+A2:2013 (