EN 50250-2002 en Conversion adaptors for industrial use (Incorporating Corrigendum August 2007 Incorporates Amendment A1 2015)《工业用转换适配器 合并勘误表2007年8月》.pdf

上传人:confusegate185 文档编号:716840 上传时间:2019-01-04 格式:PDF 页数:34 大小:1.09MB
下载 相关 举报
EN 50250-2002 en Conversion adaptors for industrial use (Incorporating Corrigendum August 2007 Incorporates Amendment A1 2015)《工业用转换适配器 合并勘误表2007年8月》.pdf_第1页
第1页 / 共34页
EN 50250-2002 en Conversion adaptors for industrial use (Incorporating Corrigendum August 2007 Incorporates Amendment A1 2015)《工业用转换适配器 合并勘误表2007年8月》.pdf_第2页
第2页 / 共34页
EN 50250-2002 en Conversion adaptors for industrial use (Incorporating Corrigendum August 2007 Incorporates Amendment A1 2015)《工业用转换适配器 合并勘误表2007年8月》.pdf_第3页
第3页 / 共34页
EN 50250-2002 en Conversion adaptors for industrial use (Incorporating Corrigendum August 2007 Incorporates Amendment A1 2015)《工业用转换适配器 合并勘误表2007年8月》.pdf_第4页
第4页 / 共34页
EN 50250-2002 en Conversion adaptors for industrial use (Incorporating Corrigendum August 2007 Incorporates Amendment A1 2015)《工业用转换适配器 合并勘误表2007年8月》.pdf_第5页
第5页 / 共34页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 50250:2002Incorporating corrigendum Conversion adaptors for industrial useICS 29.120.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3

2、g47g36g58+A1:2015August 2007National forewordThis British Standard is the UK implementation of EN 50250:2002+A1:2015, The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment. F

3、or example, text altered by CENELEC amendment A1 is indicated by !“.The UK participation in its preparation was entrusted by Technical Committee PEL/23, Electrical accessories, to Subcommittee PEL/23/4, Protected type plugs and sockets.A list of organizations represented on this committee can be obt

4、ained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 50250:2002+A1:2015This British Standard

5、waspublished under the authorityof the Standards Policy andStrategy Committeeon 28 July 2003Amendments/corrigenda issued since publicationAmd. No. Date Comments 17363Corrigendum No. 128 September 2007 Implementation of CENELECcorrigendum August 200731 May 2015 Implementation of CENELEC amendment A1:

6、2015ISBN 978 0 580 88065 0 The British Standards Institution 2015.Published by BSI Standards Limited 2015incorporating corrigendum August 2007. It supersedes BS EN 50250:2002which is withdrawn.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardi

7、zation Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50250:2002 E I

8、CS 29.120.20 Supersedes EN 50250:1998Incorporates Corrigendum August 2007English version Conversion adaptors for industrial use Adaptateurs de conversion pour usages industriels bergangsadapter fr industrielle Anwendung This European Standard was approved by CENELEC on 2002-07-02. CENELEC members ar

9、e bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to

10、the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the

11、 same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland

12、 and United Kingdom. March 2015EN 50250:2002+A1 2 Foreword This European Standard was prepared by the CENELEC BTWG 79-1, Conversion adaptors forindustrial use. The text of the draft was submitted to the Unique Acceptance Procedure and was approvedby CENELEC as EN 50250 on 2002-07-02. This European S

13、tandard supersedes EN 50250:1998. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-07-01 - latest date by which the national standards conflicting with the EN have to be

14、 withdrawn (dow) 2005-07-01 Annexes designated “normative“ are part of the body of the standard. Annexes designated “informative“ are given for information only. In this standard, Annexes AA and CC are normative and Annex BB is informative. The contents of the corrigendum of August 2007 have been in

15、cluded in this copy. _ This amendment (EN 50250:2002/A1:2015) was prepared by the CLC/SR 23H, “Industrial plugs and socket-outlets“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endors

16、ement (dop) 2016-01-19 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2018-01-19 This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC) This

17、 standard was amended to correct references in the Annexes. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Foreword to amendment A1BS

18、 EN 50250:2002+A1:2015 EN 50250:2002+A1:2015 (E)- 3 Introduction This standard applies to conversion adaptors, hereinafter referred to as adaptors, for industrial use comprising a housing incorporating a plug and socket-outlets which can be used to connect one or two plugs of the domestic type to an

19、 industrial 2P + 16 A, 250 V, 6 h, type socket-outlet. This standard shall be used jointly with EN 60309-1 “Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements“, EN 60309-2 “Plugs, socket-outlets and couplers for industrial purposes Part 2: Dimensional interchan

20、geability requirements for pin and contact-tube accessories“ and with the relevant national standards for socket-outlets for household and similar use (listed in Annex AA). The clauses in this standard amend or replace the clauses of the above mentioned EN 60309-1. BS EN 50250:2002+A1:2015 EN 50250:

21、2002+A1:2015 (E) 4 1 Scope Replacement: This standard applies to conversion adaptors intended mainly for industrial use, comprising a housing of insulating material which incorporates an industrial 2P + , 16 A, 6 h 250 V type plug part (Table 104 in standard EN 60309-2) and one or two socket-outlets

22、 in accordance with the relevant national standards for socket-outlets for household and similar use, with a rated current up to 16 A, intended mainly for industrial use either indoors or outdoors. Adaptors can be used in conjunction with socket-outlets and/or connectors This standard applies to all

23、 applications where the ambient temperature does not normally exceed 40 C. The use of these adaptors on building sites, for agricultural, commercial and domestic applications is not precluded but care should be taken in considering protecting devices in use. Adaptors are for temporary use only. In l

24、ocations where special conditions prevail, for example on board ship or where explosions are liable to occur, additional requirements may be necessary. 2 Normative references This clause of EN 60309-1 is applicable with the following additions: EN 60309-1 1999 Plugs, socket-outlets and couplers for

25、industrial purposes - Part 1: General requirements (IEC 60309-1:1999) EN 60309-2 1999 Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories (IEC 60309-2:1999) EN 60529 1991 Degrees of protection provided

26、by enclosures (IP Code) (IEC 60529:1989) NOTE See Annex AA for national standards for domestic socket-outlets. BS EN 50250:2002+A1:2015 EN 50250:2002+A1:2015 (E)EN 5 0525-2-1 1 2011 Electric cables - Low voltage energy cables of rated voltages up toand including 450/750 V (Uo/U) - Part 2-11: Cables

27、for generalapplications - Flexible cables with thermoplastic PVC insulation!“ 5 3 Definitions This clause of EN 60309-1 is applicable with the following additions: 3.101 adaptor portable accessory which allows the connection of one or more types of plug to a socket-outlet not designed to accept such

28、 plugs 3.101.1 single adaptor adaptor having a single plug function and a single socket-outlet function 3.101.2 double adaptor adaptor having a single plug function and two socket-outlet functions. The two socket-outlets may or may not comply with the same dimensional requirements 3.102 rated curren

29、t of an adaptor - the rated current of the plug part of the adaptor, or - the sum of the rated currents of the plugs that can be inserted into the adaptor, whichever is the lower 3.103 serviceable adaptor an adaptor which can be disassembled, using ordinary tools (e.g. screwdrivers, etc.) for replac

30、ement or maintenance 3.104 non-serviceable adaptor an adaptor which cannot be disassembled using ordinary tools (e.g. screwdrivers, etc.) without rendering it permanently useless 4 General This clause of EN 60309-1 is applicable except as follows. 4.1 General requirements Replacement: Adaptors shall

31、 be so designed and constructed that in normal use their performance is reliable and without danger to the user or surroundings. In general, compliance is checked by carrying out all the tests specified. BS EN 50250:2002+A1:2015 EN 50250:2002+A1:2015 (E) 6 4.2 General notes on tests 4.2.1 Replacemen

32、t: Tests according to this standard are type tests. The parts of adaptors are tested, unless otherwise specified, in accordance with the requirements of the relevant standard, as applicable; e.g. plug part is tested according to EN 60309-2 and socket-outlet parts are tested according to the relevant

33、 national standards. 4.2.4 Replacement: Unless otherwise specified, one set of three specimens shall be subjected to all the tests. 4.2.5 Replace the first paragraph of the note by: NOTE In general, it will only be necessary to repeat the tests which caused the failure, unless the specimens fail in

34、test of Clause 21, in which case tests shall be repeated from Clause 20 onwards. Addition: 4.2.101 If gauges are used, these shall be of hardened steel, and all corners shall be slightly rounded-off with a maximum radius of 0,1 mm and the surface-finish for all measurement-surfaces shall be N8 min,

35、unless otherwise specified. 5 Standard ratings Replacement: 5.1 Rated voltage: The rated voltage is 250 V . 5.2 Rated current: Rated current: 13 A, 15 A and 16 A. NOTE 13 A rated current is allowed only in countries where plugs are fused. 6 Classification Replacement: 6.1 Adaptors are classified: 6.

36、1.1 According to the degree of protection against harmful ingress of water in accordance with EN 60529 - IPX0 (non-protected), - IP X4 (protected). BS EN 50250:2002+A1:2015 EN 50250:2002+A1:2015 (E) 7 NOTE The degree of protection of the socket-outlets for industrial use, when used in conjunction wi

37、th an adaptor, will revert to the protection rating of the adaptor if this is less than that of the socket-outlet. 6.1.2 According to the type of construction - serviceable adaptors, - non-serviceable adaptors. 7 Marking Replacement: 7.1 Adaptors shall be marked with - rated current in amperes, - ra

38、ted operating voltage or range in volts, - symbol for nature of supply, - either the name or trade mark of the manufacturer or of the responsible vendor, - type reference, which may be a catalogue number, - symbol for degree of protection (IP code), - symbol indicating the position of the earthing c

39、ontact (plug part side), - wording “FOR TEMPORARY USE ONLY“. Adaptors shall be provided with manufacturer instruction stating that - for adaptors having a degree of protection IPX0 the user should be aware that the degree of protection of the industrial socket-outlet in which it will be inserted wil

40、l be reduced, - adaptors shall not be used in explosive atmosphere. NOTE 1 This wording should be written in the official language of the country of intended use. Compliance is checked by inspection. NOTE 2 Marking 10/16 should be accepted as indication for socket-outlet parts in accordance with sta

41、ndard CEE 7. The symbol indicating the position of the earthing contact shall be placed before or above the figure indicating the rated operating voltage, and separated from it by a line. These markings shall be placed after that for rated current, separated from it by a dash, if an oblique line sep

42、arates the symbol indicating the position of the earthing contact from the figure for the rated operating voltage. If a symbol for nature of supply is used, it shall be placed next to or below the marking for rated operating voltage. BS EN 50250:2002+A1:2015 EN 50250:2002+A1:2015 (E) 8 The marking f

43、or rated current, position of the earthing contact, rated operating voltage(s) and the nature of the supply may accordingly be as follows: 16 A - 6 h/250 V, or 16 - 6 h/250, or 16 - 6h250 7.2 When symbols are used, they shall be as follows: A amperes; V volts; alternating current; earth; IPXX degree

44、 of protection according to EN 60529. For marking of rated current(s) and rated operating voltage(s) or range(s), figures may be used alone. Compliance is checked by inspection. 7.3 The marking specified in 7.1 shall be readily visible when the adaptor is equipped and ready for use, with the excepti

45、on of the wording “FOR TEMPORARY USE ONLY“ which shall also be visible when the adaptor is in use. NOTE 1 The term “ready for use“ does not imply that the adaptor is in engagement with its complementary accessory. NOTE 2 The marking for rated current, nature of supply, rated operating voltage and th

46、e name, trade mark of the manufacturer or the responsible vendor, may be repeated on the lid, if any. Compliance is checked by inspection. 7.4 In serviceable adaptors the earthing contacts shall be indicated by the symbol . This symbol shall be placed close to the corresponding terminals, and should

47、 not be placed on screws, washers or other removable parts. 7.5 Markings shall be indelible and easily legible. Compliance is checked by inspection and by the following test. After the humidity treatment in Clause 18 the marking shall be rubbed vigorously by hand for 15 s with a piece of cloth soake

48、d in water and again for 15 s in a piece of cloth soaked in petroleum spirit. Special attention is paid to the marking of the name, trade mark or identification mark of the manufacturer or the responsible vendor and to that of the nature of supply and to the warning note. NOTE It is recommended that

49、 the petroleum spirit used is of a type consisting of a solvent hexane with an aromatic content of maximum 0,1 volume percentage, a kauri-buthanol value of 29, an initial boiling point of approximately 65 C, a dry point of approximately 69 C and a density of approximately 0,68 g/cm3. BS EN 50250:2002+A1:2015 EN 50250:2002+A1:2015 (E) 9 7.6 If, in addition to the marking prescribed, the rated operating voltage is indicated by means of a colour, the colour code shall be blue. An indicating colour, if different from that of the