EN 50264-2-1-2008 en Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1 Cables with crosslinked elastomeric insulation.pdf

上传人:appealoxygen216 文档编号:716844 上传时间:2019-01-04 格式:PDF 页数:28 大小:367.13KB
下载 相关 举报
EN 50264-2-1-2008 en Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1 Cables with crosslinked elastomeric insulation.pdf_第1页
第1页 / 共28页
EN 50264-2-1-2008 en Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1 Cables with crosslinked elastomeric insulation.pdf_第2页
第2页 / 共28页
EN 50264-2-1-2008 en Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1 Cables with crosslinked elastomeric insulation.pdf_第3页
第3页 / 共28页
EN 50264-2-1-2008 en Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1 Cables with crosslinked elastomeric insulation.pdf_第4页
第4页 / 共28页
EN 50264-2-1-2008 en Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1 Cables with crosslinked elastomeric insulation.pdf_第5页
第5页 / 共28页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 50264-2-1:2008Railway applications Railway rolling stock power and control cables having special fire performance Part 2-1: Cables with crosslinked elastomeric insulation Single core cablesICS 13.220.20; 29.060.20; 45.060.01g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3

2、g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 50264-2-1:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 August 2008 BSI 2008ISBN

3、978 0 580 55568 8National forewordThis British Standard is the UK implementation of EN 50264-2-1:2008. It supersedes BS EN 50264-2:2002 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/12, Railway cables.A

4、 list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from l

5、egal obligations. Amendments/corrigenda issued since publicationDate CommentsEUROPEAN STANDARD EN 50264-2-1 NORME EUROPENNE EUROPISCHE NORM June 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnisc

6、he Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50264-2-1:2008 E ICS 13.220.20; 29.060.20; 45.060.01 Supersedes EN 50264-2:2002English version Railway appl

7、ications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables Applications ferroviaires - Cbles de puissance et de contrle comportement au feu spcifi pour matriel roulant ferroviaire - Partie

8、2-1: Cbles enveloppe isolante rticule - Cbles monoconducteurs Bahnanwendungen - Starkstrom- und Steuerleitungen fr Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2-1: Leitungen mit vernetzter elastomerer Isolierung - Einadrige Leitungen This European Standard was approved by CENELE

9、C on 2008-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards

10、 may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified

11、 to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, L

12、uxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50264-2-1:2008 2 Foreword This European Standard was prepared by Working Group 12, Railway cables, of the Technical Committee CENELEC TC 20, Electric cables

13、, as part of the overall programme of work in the Technical Committee CENELEC TC 9X, Electrical and electronic applications for railways. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50264-2-1 on 2008-03-01. This European Standard supersedes EN 50264-2:200

14、2. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-03-01 _ BS EN

15、 50264-2-1:2008 3 EN 50264-2-1:2008 Contents Page Introduction . 5 1 Scope 6 2 Normative references 6 3 Definitions 7 4 Rated voltage . 7 5 Marking and identification 7 5.1 Marking of cable 7 5.2 Core identification 8 5.3 Sheath . 8 6 Construction of cables 8 6.1 General 8 6.2 Conductor 8 6.3 Conduc

16、tor screening . 8 6.4 Separator . 8 6.5 Insulation system. 8 6.6 Sheath . 9 6.7 Constructional components . 9 7 Tests . 15 7.1 Definitions relating to tests 15 7.2 Conductor resistance 15 7.3 Voltage test . 15 7.4 Insulation resistance . 15 7.5 Dielectric strength 15 7.6 Spark test 16 7.7 DC stabili

17、ty 16 7.8 Surface resistance. 16 7.9 Ageing test 16 7.10 Hot set test 17 7.11 Compatibility 17 7.12 Water absorption on sheath 17 7.13 Ozone resistance 17 7.14 Mineral oil resistance 18 7.15 Fuel resistance 18 7.16 Acid and alkali resistance 19 7.17 Bending test at low temperature (cables with OD 12

18、,5 mm) . 19 7.18 Cold elongation test (cables with OD 12,5 mm) 19 7.19 Impact test at low temperature 20 7.20 Reaction to fire Cable . 20 7.21 Reaction to fire Components 20 Annex A (normative) Code designation 24 Bibliography 25 BS EN 50264-2-1:2008EN 50264-2-1:2008 4 Tables Table 1 General data Ca

19、ble type (0,6/1 kV unsheathed) . 11 Table 2 General data Cable type (1,8/3 kV unsheathed) . 12 Table 3 General data Cable type (1,8/3 kV sheathed) . 13 Table 4 General data Cable type (3,6/6 kV sheathed) . 14 Table 5 Schedule of tests for cables . 21 BS EN 50264-2-1:2008 5 EN 50264-2-1:2008 Introduc

20、tion The EN 50264 series covers a range of cables, based upon halogen free materials, for use in railway rolling stock. It is divided into 5 parts under the generic title “Railway applications - Railway rolling stock power and control cables having special fire performance”: Part 1 General requireme

21、nts; Part 2-1 Cables with crosslinked elastomeric insulation Single core cables; Part 2-2 Cables with crosslinked elastomeric insulation Multicore cables; Part 3-1 Cables with crosslinked elastomeric insulation with reduced dimensions Single core cables; Part 3-2 Cables with crosslinked elastomeric

22、insulation with reduced dimensions Multicore cables. Information regarding selection and installation of cables, including current ratings can be found in EN 50355 and EN 50343. The procedure for selection of cable cross-sectional area, including reduction factors for ambient temperature and install

23、ation type, is described in EN 50343. Special test methods referred to in EN 50264 are given in EN 50305. The cables in EN 50264-2-1 may also be used in EN 50264-2-2 to build up multicore sheathed cables. Part 1, “General requirements”, contains a more extensive introduction to EN 50264, and should

24、be read in conjunction with this Part 2-1. BS EN 50264-2-1:2008EN 50264-2-1:2008 6 1 Scope EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: 0,6/1 kV unscreened, unsheathed (1 mm to 400 mm); 1,8/3 kV unscreene

25、d, unsheathed (1,5 mm to 400 mm); 1,8/3 kV unscreened, sheathed (1,5 mm to 400 mm); 3,6/6 kV unscreened, sheathed (2,5 mm to 400 mm). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiri

26、ng, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 C and a maximum temperature for short circuit conditions of 200 C based on a duration of 5 s. Under fire conditions the cables exhibit special performance

27、 characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”. 2 Normative references The following referenced documents are indispensable fo

28、r the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 10002-1 Metallic materials Tensile testing Methods of test at ambient temperature EN 50264-1:2008 Rai

29、lway applications Railway rolling stock power and control cables having special fire performance Part 1: General requirements EN 50266-2-4 Common test methods for cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables Part 2-4: Procedures Category C

30、 EN 50266-2-5 Common test methods for cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables Part 2-5: Procedures Small cables Category D EN 50305:2002 Railway applications Railway rolling stock cables having special fire performance Test methods EN

31、 60228 Conductors of insulated cables (IEC 60228) EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame (IEC 60332-1-2) EN 60811-1-1:1995 Insulating and sheat

32、hing materials of electric and optical cables Common test methods Part 1-1: General application Measurement of thickness and overall dimensions Tests for determining the mechanical properties (IEC 60811-1-1:1993) BS EN 50264-2-1:2008 7 EN 50264-2-1:2008 EN 60811-1-2:1995 Insulating and sheathing mat

33、erials of electric cables Common test methods Part 1-2: General application Thermal ageing methods (IEC 60811-1-2:1985 + A1:1989 + corr. May 1986) EN 60811-1-3:1995 Insulating and sheathing materials of electric and optical cables Common test methods Part 1-3: General application Methods for determi

34、ning the density Water absorption tests Shrinkage test (IEC 60811-1-3:1993) EN 60811-1-4:1995 Insulating and sheathing materials of electric and optical cables Common test methods Part 1-4: General application Tests at low temperature (IEC 60811-1-4:1985 + A1:1993 + corr. May 1986) EN 60811-2-1:1998

35、 Insulating and sheathing materials of electric and optical cables Common test methods Part 2-1: Methods specific to elastomeric compounds Ozone resistance, hot set and mineral oil immersion tests (IEC 60811-2-1:1998) EN 61034-2 Measurement of smoke density of cables burning under defined conditions

36、 Part 2: Procedure and requirements (IEC 61034-2) HD 308 Identification of cores in cables and flexible cords 3 Definitions For the purposes of this document, the terms and definitions given in EN 50264-1 apply. 4 Rated voltage The rated voltage for single-core insulated cables shall be as follows:

37、a) unsheathed: 0,6/1 kV; 1,8/3 kV; b) sheathed: 1,8/3 kV; 3,6/6 kV. 5 Marking and identification 5.1 Marking of cable Cables shall be marked with the following: manufacturers name; EN reference; voltage rating (Uo); conductor size; a code designation according to Annex A. An example of a complete ma

38、rk is: XYZ EN 50264-2-1 1800 V 400 FF The marking shall conform to the requirements of EN 50264-1, Clause 5. BS EN 50264-2-1:2008EN 50264-2-1:2008 8 5.2 Core identification The core insulation of all cables shall be black unless otherwise specified. If a colour other than black is specified it shall

39、 be a colour in accordance with HD 308. The colour shall be on the surface or throughout the insulation. The colour shall be clearly identifiable and durable. Durability shall be checked by the test given in EN 50305, 10.1. Conformity with these requirements shall be verified by visual examination.

40、5.3 Sheath The sheath shall be black unless otherwise specified. 6 Construction of cables 6.1 General The cable shall conform to the applicable general requirements given in EN 50264-1 and to the specific requirements of this part. Conformity with the requirements shall be checked by inspection and

41、by the tests given in Table 5. The cable dimensions shall be as given in Tables 1 to 4 as appropriate to the cable type. 6.2 Conductor Conductors shall be tin-coated annealed copper, class 5, according to EN 60228. When tested in accordance with EN 10002-1 the minimum average elongation of the wires

42、 from the conductor shall be 15 %, with a minimum value of 10 % for any individual wire. NOTE It is not necessary to test every individual wire. 5 % of wires or 10 wires, whichever is the least number, should be selected at random. 6.3 Conductor screening For cables in Table 4 conductor screening sh

43、all be as given in EN 50264-1, 6.1.6. 6.4 Separator 6.4.1 A separator may be used over the conductor if the cable construction does not include a conductor screen. 6.4.2 A separator may be included between the insulation and the sheath. 6.5 Insulation system The insulation shall be one or more extru

44、ded materials as defined in EN 50264-1 applied so as to meet the requirements of EI 101 to EI 105. BS EN 50264-2-1:2008 9 EN 50264-2-1:2008 For single-core unsheathed and sheathed cable: EI 101 low temperature resistant, oil resistant; EI 102 extra low temperature resistant, oil resistant; EI 103 lo

45、w temperature resistant, extra oil and fuel resistant; EI 104 extra low temperature resistant, extra oil and fuel resistant. For sheathed cables: EI 105 extra low temperature resistant, non oil resistant. EI 105 may be used as the inner layer of a multilayer insulation system. To claim extra low tem

46、perature performance both insulation and sheath shall be extra low temperature resistant. The insulation shall be applied to meet the requirements of EN 50264-1, 6.2. The insulation thickness shall conform to the specified value given in Tables 1 to 4. 6.6 Sheath Sheath shall be an extruded material

47、 as defined in EN 50264-1 applied so as to meet the requirements of compound type EM 101, EM 102, EM 103 or EM 104: EM 101 low temperature resistant, oil resistant; EM 102 extra low temperature resistant, oil resistant; EM 103 low temperature resistant, extra oil and fuel resistant; EM 104 extra low

48、 temperature resistant, extra oil and fuel resistant. The sheath shall consist of one or more closely adherent layers of the same type. The sheath shall be applied to meet the requirements of EN 50264-1, 6.6. The sheath thickness shall conform to the specified value given in Tables 3 and 4. 6.7 Cons

49、tructional components 6.7.1 Unsheathed cable (Tables 1 and 2 - 0,6/1 kV and 1,8/3 kV) Cable in Tables 1 and 2 shall be composed of the following components in the order given: conductor flexible tin coated annealed copper, class 5; separator optional; insulation a compound or compounds given in 6.5. BS EN 50264-2-1:2008EN 50264-2-1:2008 10 6.7.2 Sheathed cable (Table 3 1,8/

展开阅读全文
相关资源
猜你喜欢
  • DIN 5194-1966 Tapered square shanks for hand brace bits《手摇钻的锥形方柄》.pdf DIN 5194-1966 Tapered square shanks for hand brace bits《手摇钻的锥形方柄》.pdf
  • DIN 51940-2012 Testing of carbonaceous materials - Sampling and sample preparation - Solid materials solid binders and impregnants《含碳物质的试验 取样和样品制备 固体材料 固定粘接剂和浸渍剂》.pdf DIN 51940-2012 Testing of carbonaceous materials - Sampling and sample preparation - Solid materials solid binders and impregnants《含碳物质的试验 取样和样品制备 固体材料 固定粘接剂和浸渍剂》.pdf
  • DIN 51941-1-2008 Testing of carbonaceous materials - Determination of chemical composition - Part 1 Sample preparation solid materials solid binders and impregnants《碳素材料测试 化学成分测定 第.pdf DIN 51941-1-2008 Testing of carbonaceous materials - Determination of chemical composition - Part 1 Sample preparation solid materials solid binders and impregnants《碳素材料测试 化学成分测定 第.pdf
  • DIN 51942 Berichtigung 1-2006 Testing of carbonaceous materials - Determination of dynamic moduls of elasticity by pulse excitation - Solid materials Corrigenda to DIN 51942 2002-0.pdf DIN 51942 Berichtigung 1-2006 Testing of carbonaceous materials - Determination of dynamic moduls of elasticity by pulse excitation - Solid materials Corrigenda to DIN 51942 2002-0.pdf
  • DIN 51942-2002 Testing of carbonaceous materials - Determination of dynamic modulus of elasticity by pulse excitation - Solid materials《炭素材料试验 采用脉冲激励法测定动态弹性模量 固体材料》.pdf DIN 51942-2002 Testing of carbonaceous materials - Determination of dynamic modulus of elasticity by pulse excitation - Solid materials《炭素材料试验 采用脉冲激励法测定动态弹性模量 固体材料》.pdf
  • DIN 51944 Corrigendum 1-2006 Testing of carbonaceous materials - Determination of flexural strength by four point method - Soild materials Corrigendum 1 to English version of DIN 5.pdf DIN 51944 Corrigendum 1-2006 Testing of carbonaceous materials - Determination of flexural strength by four point method - Soild materials Corrigendum 1 to English version of DIN 5.pdf
  • DIN 51944-2009 Testing of carbonaceous materials - Determination of flexural strength by four point method - Solid materials《含碳材料的测试 四点法测定挠曲强度 实心材料》.pdf DIN 51944-2009 Testing of carbonaceous materials - Determination of flexural strength by four point method - Solid materials《含碳材料的测试 四点法测定挠曲强度 实心材料》.pdf
  • DIN 51947-1998 Carbonaceous materials - Terms《含碳材料 术语》.pdf DIN 51947-1998 Carbonaceous materials - Terms《含碳材料 术语》.pdf
  • DIN 5200-2009 Assembly tools for screws and nuts - Screwdrivers for slotted head screws double offset - Dimensions and requirements《螺钉和螺母用装配工具 双偏置槽头螺钉用螺丝刀 尺寸规格和要求》.pdf DIN 5200-2009 Assembly tools for screws and nuts - Screwdrivers for slotted head screws double offset - Dimensions and requirements《螺钉和螺母用装配工具 双偏置槽头螺钉用螺丝刀 尺寸规格和要求》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1