EN 50288-5-1-2013 en Multi-element metallic cables used in analogue and digital communication and control - Part 5-1 Sectional specification for screened cables characterized up to.pdf

上传人:postpastor181 文档编号:716873 上传时间:2019-01-04 格式:PDF 页数:20 大小:957.70KB
下载 相关 举报
EN 50288-5-1-2013 en Multi-element metallic cables used in analogue and digital communication and control - Part 5-1 Sectional specification for screened cables characterized up to.pdf_第1页
第1页 / 共20页
EN 50288-5-1-2013 en Multi-element metallic cables used in analogue and digital communication and control - Part 5-1 Sectional specification for screened cables characterized up to.pdf_第2页
第2页 / 共20页
EN 50288-5-1-2013 en Multi-element metallic cables used in analogue and digital communication and control - Part 5-1 Sectional specification for screened cables characterized up to.pdf_第3页
第3页 / 共20页
EN 50288-5-1-2013 en Multi-element metallic cables used in analogue and digital communication and control - Part 5-1 Sectional specification for screened cables characterized up to.pdf_第4页
第4页 / 共20页
EN 50288-5-1-2013 en Multi-element metallic cables used in analogue and digital communication and control - Part 5-1 Sectional specification for screened cables characterized up to.pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 50288-5-1:2013Multi-element metallic cablesused in analogue and digitalcommunication and control -Part 5-1: Sectional specification forscreened cables characterized up to 250MHz Horizontal and building backbonecablesBS EN 50288-5-1:2013 BRITISH STANDARDNational forewor

2、dThis British Standard is the UK implementation of EN50288-5-1:2013. It supersedes BS EN 50288-5-1:2003 which iswithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EPL/46, Cables, wires and waveguides, radio frequencyconnectors and accessories for communication and

3、signalling.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2014. Published by B

4、SI StandardsLimited 2014ISBN 978 0 580 77100 2ICS 33.120.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 28 February 2014.Amendments issued since publicationDate

5、 Text affectedBS EN 50288-5-1:2013EUROPEAN STANDARD EN 50288-5-1 NORME EUROPENNE EUROPISCHE NORM May 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix

6、17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50288-5-1:2013 E ICS 33.120.20 Supersedes EN 50288-5-1:2003 English version Multi-element metallic cables used in analogue and digital communication and co

7、ntrol - Part 5-1: Sectional specification for screened cables characterized up to 250 MHz - Horizontal and building backbone cables Cbles mtalliques lments multiples utiliss pour les transmissions et les commandes analogiques et numriques - Partie 5-1: Spcification intermdiaire pour les cbles blinds

8、 pour applications jusqu 250 MHz - Cbles horizontaux et cbles verticaux de btiment Mehradrige metallische Daten- und Kontrollkabel fr analoge und digitale bertragung - Teil 5-1: Rahmenspezifikation fr geschirmte Kabel bis 250 MHz - Kabel fr den Horizontal- und Steigbereich This European Standard was

9、 approved by CENELEC on 2013-03-18. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such

10、 national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into

11、its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Mac

12、edonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50288-5-1:2013EN 50288-5-1:2013 - 2 - Contents Page Forewo

13、rd . 3 1 Scope . 4 2 Normative references 4 3 Terms, definitions, symbols and abbreviations . 4 3.1 Terms and definitions . 4 3.2 Symbols and abbreviations . 4 4 Cable construction . 5 4.1 Conductor 5 4.2 Insulation . 5 4.3 Cabling elements . 5 4.4 Identification of cabling elements . 5 4.5 Screenin

14、g of cabling elements 5 4.6 Cable make-up 5 4.7 Filling compound 5 4.8 Interstitial fillers . 5 4.9 Screening of the cable core 5 4.10 Moisture barriers 5 4.11 Wrapping layers . 5 4.12 Sheath . 6 5 Tests and requirements for completed cables 6 5.1 Electrical tests . 6 5.2 Mechanical tests . 9 5.3 En

15、vironmental tests 10 5.4 Fire performance tests . 10 Annex A (informative) Maximum voltage, current and temperature rating for cables used for POE applications 12 Annex B (informative) Blank detail specification 13 BS EN 50288-5-1:2013- 3 - EN 50288-5-1:2013 Foreword This document (EN 50288-5-1:2013

16、) has been prepared by CLC/SC 46XC “Multicore, Multipair and Quad Data communication cables,“ of CLC/TC 46X, “Communication cables“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endors

17、ement (dop) 2014-03-18 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2016-03-18 This document supersedes EN 50288-5-1:2003. EN 50288-5-1:2013 includes the following significant technical changes with respect to EN 50288-5-1:2003: the addition o

18、f the Blank Detail Specification Annex; a number minor corrections and updating of references; the re-classification of ELFEXT to ACR-F. This Part 5-1 is to be read in conjunction to EN 50288-1. Attention is drawn to the possibility that some of the elements of this document may be the subject of pa

19、tent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). BS EN 50288-5-1:2013EN 50288-5

20、-1:2013 - 4 - 1 Scope EN 50288-5-1 is a sectional specification for screened cables, characterised from 1 MHz up to 250 MHz, to be used in horizontal and building backbone wiring as defined in EN 50173. This sectional specification contains the electrical, mechanical, transmission and environmental

21、performance characteristics of the cables, when tested in accordance with the referenced test methods. This sectional specification is to be read in conjunction with EN 50288-1 that contains the essential provisions for its application. The cables covered in this sectional specification are intended

22、 to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains. 2 Normative references The following documents, in whole or in p

23、art, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50173 Series Information technology - Generic

24、 cabling systems EN 50288-1 Multi-element metallic cables used in analogue and digital communication and control - Part 1: Generic specification EN 50289 Series Communication cables - Specifications for test methods EN 50290 Series Communication cables EN 60811 Series Electric and optical fibre cabl

25、es - Test methods for non-metallic materials (IEC 60811 series) IEC 60189-2 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations 3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions Fo

26、r the purposes of this document the terms and definitions given in EN 50288-1 and the following apply. 3.1.1 screening of cable a cable is considered screened when the cable core is covered by a continuous conductive layer forming part of the shielding and grounding system Note 1 to entry: d.c. cont

27、inuity has to be given and minimum shielding requirements have to be met. 3.2 Symbols and abbreviations For the purposes of this document, the following abbreviations apply. EX Exogenous (derived or originating externally) POE Power Over Ethernet BS EN 50288-5-1:2013- 5 - EN 50288-5-1:2013 4 Cable c

28、onstruction 4.1 Conductor The conductor shall be solid copper and meet the requirements of EN 50288-1, 4.1. The conductor shall be plain or metal coated. The nominal conductor diameter shall be 0,5 mm and 0,8 mm. NOTE Constructions with copper clad conductors do not meet the requirements. 4.2 Insula

29、tion The insulation shall be of a suitable material according to the relevant part of EN 50290-2. 4.3 Cabling elements The cable element shall be a pair or a quad. 4.4 Identification of cabling elements Unless otherwise specified, the colour coding for identification is given in IEC 60189-2. The col

30、ours shall meet the requirements of EN 50288-1, 4.4. 4.5 Screening of cabling elements Where appropriate, screening of the cabling elements shall be applied in accordance with 4.5 of EN 50288-1. Coverage is defined in EN 50290-2-1. 4.6 Cable make-up The cable elements shall be laid up in concentric

31、layer(s) or units to form the cable core. 4.7 Filling compound Not applicable. 4.8 Interstitial fillers Where fillers are used they shall meet the requirements of 4.8 of EN 50288-1. 4.9 Screening of the cable core The screening of the cable core shall be applied in accordance with EN 50288-1, 4.9. C

32、overage is defined in EN 50290-2-1. 4.10 Moisture barriers Not applicable. 4.11 Wrapping layers Where wrapping layers are used they shall be in accordance with EN 50288-1, 4.11. BS EN 50288-5-1:2013EN 50288-5-1:2013 - 6 - 4.12 Sheath The sheath shall be of a suitable material according to the releva

33、nt part of EN 50290-2. 5 Tests and requirements for completed cables The following tables give the tests to be applied, together with the respective limits, in order to demonstrate compliance with this specification. 5.1 Electrical tests 5.1.1 Low-frequency and d.c. electrical measurements Table 1 -

34、Low-frequency and d.c. electrical measurements EN 50288-1 sub-clause Parameter Requirement 5.1.1.1 Conductor loop resistance 19,0 /100 m 5.1.1.2 Conductor resistance unbalance 2,0 % 5.1.1.2.1 Pair resistance unbalance 4,0 % 5.1.1.3 Dielectric strength conductor/conductor and conductor/screen 1,0 kV

35、d.c. or 0,7 kV a.c. for 1 min or 2,5 kV d.c. or 1,7 kV a.c. for 2 s 5.1.1.4 Insulation resistance 5 000 M km when tested in accordance with EN 50289-1-4 5.1.1.5 Mutual capacitance No requirement specified 5.1.1.6 Capacitance unbalance to earth 1 200 pF/km BS EN 50288-5-1:2013- 7 - EN 50288-5-1:2013

36、5.1.2 High-frequency electrical and transmission measurements Table 2 - High-frequency electrical and transmission requirements EN 50288-1 sub-clause Parameter Requirement 5.1.2.1 Velocity of propagation Phase delay 534+36/f ns/100 m, 1 MHz f 250 MHz 5.1.2.2 Propagation delay difference (skew) 45 ns

37、/100 m at 100 MHz 5.1.2.3 Longitudinal attenuation 2) 3) 4)5.1.2.4 Near-end unbalance attenuation 40-10log(f) dB, 1 MHz f 250 MHz; 5.1.2.5 Near-end crosstalk (NEXT)1) 2)5.1.2.6 Attenuation to crosstalk ratio at the far end 2) 6) (ACR-F) 1 4 10 16 20 31,25 62,5 100 155 200 250 MHz 66,0 58,0 50,0 45,9

38、 44,0 40,1 34,1 30,0 26,2 24,0 22,0 dB 70-20log(f), 1 MHz f 250 MHz (maximum 66 dB), values referenced to 100 m 5.1.2.7.1 Power sum near-end crosstalk 2) (PSNEXT) 1 4 10 16 20 31,25 62,5 100 155 200 250 MHz 72.3 63,3 57,3 54,2 52,8 49,9 45,4 42,3 39,4 37,8 36,3 dB 72,3-15log(f), 1 MHz f 250 MHz 5.1.

39、2.7.2 Power Sum Attenuation to crosstalk ratio at the far end 2) 6) (PSACR-F) 1 4 10 16 20 31,25 62,5 100 155 200 250 MHz 64,0 55,0 47,0 43,0 41,0 37,1 31,1 27,0 23,2 21,0 19,0 dB 67-20log(f), 1 MHz f 250 MHz (maximum 64 dB), values referenced to 100 m 5.1.2.8 Mean characteristic impedance 100 5 , 1

40、20 5 , at 100 MHz 1 4 10 16 20 31,25 62,5 100 155 200 250 MHz 2,1 3,8 6,0 7,6 8,5 10,8 15,5 19,9 25,3 29,1 33,0 dB/100 m 1,82f+0,0169f+0,25 /f, 1 MHz f 250 MHz 1 4 10 16 20 31,25 62,5 100 155 200 250 MHz 75 66 60,3 57,2 55,8 52,9 48,4 45,3 42,4 40,8 39,3 dB 75-15log(f), 1 MHz f 250 MHz BS EN 50288-5

41、-1:2013EN 50288-5-1:2013 - 8 - 5.1.2.9 Return loss2) 5)4 8 10 16 20 31,25 62,5 100 155 200 250 MHz 23,1 24,5 25,0 25,0 25,0 23,6 21,5 20,1 18,8 18,0 17,3 dB 20+5log(f), 4 MHz f 10 MHz; 25,0dB, 10 MHz f 20 MHz; 25-7log(f/20), 20 MHz f 250 MHz; 5.1.2.10 Coupling attenuation Type I 85dB , 30 MHz f 100

42、MHz 85 - 20 log f/100 dB 100 MHz f 1000 MHz Type Ib 70dB , 30 MHz f 100 MHz 70 - 20 log f/100 dB 100 MHz f 1000 MHz Type II 55dB, 30 MHz f 100 MHz 55 - 20 log f/100 dB 100 MHz f 1000 MHz 5.1.2.11 Transfer impedance Grade 1 10 m/m at 1 MHz; 10 m/m at 10 MHz; 30 m/m at 30 MHz; 100 m/m at 100 MHz Grade

43、 2 50 m/m at 1 MHz; 100 m/m at 10 MHz; 200 m/m at 30 MHz; 1000m/m at 100 MHz 1)For hybrid cables and multi-unit cables, PSNEXT between all non fibre recognised cable units shall be 3 dB better than the specified pair to pair NEXT at all specified frequencies. 2)The values in the table are for inform

44、ation only. The formula given shall be used to determine compliance, rounded to one decimal place. 3)The attenuation shall meet values adjusted for temperature up to 60 C with a temperature coefficient of 0,2 % per degree rise above 20 C. 4)Values between 1 MHz and 4 MHz are for information only. 5)

45、For the measurement of return loss a test sample having a round trip loss 40 dB at any measured frequency should be used. 6) ELFEXT is now re-classified as ACR-F, PSELFEXT is now re-classified PSACR-F, see Annex A of EN 50288-1 for explanation BS EN 50288-5-1:2013- 9 - EN 50288-5-1:2013 5.2 Mechanic

46、al tests Table 3 - Mechanical test requirements EN 50288-1 sub-clause Parameter Requirement 5.2.1 Conductor elongation at break EN 50289-3-2 10 % 5.2.2 Shrinkage of insulation EN 50289-3-4 5 % 5.2.3 Crush resistance of the cable EN 50289-3-5 1 000 N / 1 min / 100 mm Near-end crosstalk, return loss a

47、nd characteristic impedance shall remain within the specified limits 5.2.4 Impact resistance of the cable EN 50289-3-6 12,5 mm radius / 1 J / 3 impacts at 1 m from the measured end Near-end crosstalk, return loss and characteristic impedance shall remain within the specified limits 5.2.5 Abrasion re

48、sistance of the sheath marking EN 50289-3-8 Marking shall remain legible after 10 strokes Force 4N 5.2.6 Simulated installation testing of the cable 5.2.6.1 Simulated installation testing of the cable Single bend EN 50289-3-9:2001, Clause 4, procedure 2 Single bend 4 dia / 4 cycles Near-end crosstalk, return loss, characteristic impedance and coupling attenuation (u/c) shall remain within the specified limits 5.2.6.2 Simulated installation testing of the cable “S” bend EN 50289-3-9:2001, Clause 8 “S”