EN 50377-5-1-2003 en Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 5-1 Type EC terminated on IEC 60793-2 .pdf

上传人:孙刚 文档编号:717059 上传时间:2019-01-04 格式:PDF 页数:30 大小:494.73KB
下载 相关 举报
EN 50377-5-1-2003 en Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 5-1 Type EC terminated on IEC 60793-2 .pdf_第1页
第1页 / 共30页
EN 50377-5-1-2003 en Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 5-1 Type EC terminated on IEC 60793-2 .pdf_第2页
第2页 / 共30页
EN 50377-5-1-2003 en Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 5-1 Type EC terminated on IEC 60793-2 .pdf_第3页
第3页 / 共30页
EN 50377-5-1-2003 en Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 5-1 Type EC terminated on IEC 60793-2 .pdf_第4页
第4页 / 共30页
EN 50377-5-1-2003 en Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 5-1 Type EC terminated on IEC 60793-2 .pdf_第5页
第5页 / 共30页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 50377-5-1:2003 Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 5-1: Type EC terminated on IEC 60793-2 category B.1.1 singlemode fibre The European Standard EN 50377-5-1:2003 has the status of a British St

2、andard ICS 33.180.20 BS EN 50377-5-1:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 3 April 2003 BSI 3 April 2003 ISBN 0 580 41528 7 National foreword This British Standard is the official English language version of EN 50377-5-1:2003.

3、The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Interconnecting devices and passive components, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its sec

4、retary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Cata

5、logue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand

6、the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a fr

7、ont cover, an inside front cover, the EN title page, pages 2 to 27 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 50377-5-1 NORME EUROPENNE EUROPISCHE NORM

8、 March 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any mea

9、ns reserved worldwide for CENELEC members. Ref. No. EN 50377-5-1:2003 E ICS 33.180.20 English version Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications Part 5-1: Type EC terminated on IEC 60793-2 category B1.1 singlemode fibre Jeux

10、de connecteurs et composants dinterconnexion utiliser dans les systmes de communication par fibres optiques Spcifications de produit Partie 5-1: Type EC cbl sur une fibre unimodale de la catgorie B1.1 de la CEI 60793-2 Steckverbinderstze und Verbindungsbauelemente fr Lichtwellenleiter- Datenbertragu

11、ngssysteme Produktnormen Teil 5-1: Bauart EC zum Anschluss von Einmodenfasern nach IEC 60793-2, Kategorie B1.1 This European Standard was approved by CENELEC on 2002-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Eu

12、ropean Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (E

13、nglish, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austri

14、a, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 50377-5-1:2003 2 Foreword This European Standard was prepared by the Technical Commit

15、tee CENELEC TC 86BXA, Fibre optic connectors. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50377-5-1 on 2002-09-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an i

16、dentical national standard or by endorsement (dop) 2003-10-01 - latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2005-09-01 Annexes designated “normative“ are part of the body of the standard. Annexes designated “informative“ are given for information on

17、ly. In this standard, annexes A and B are normative. _ 3 EN 50377-5-1:2003 Connector sets and interconnected components to be used in optical fibre communication systems Product specifications Part 5-1: EC terminated on IEC 60793-2 category B1.1 singlemode fibre Description Performance Coupling mech

18、anism: push/pull Configuration: plug/adapter/plug Fibre Category: IEC 60793-2 type B1.1 Cable Type see Table 3 Application: Attenuation Grades: (Random Mate) Return Loss: EN 61753-2-1 category U and ETS 300 671 (see 1.3) P: 0,35 dB mean. 1,0 dB for 97 % of measurements Q: 0,30 dB mean. 0,60 dB for 9

19、9 % of measurements 60 dB Normative references: EN 50173 Information technology - Generic cabling systems EN 60794-2 Optical fibre cables - Part 2: Indoor cables Sectional specification EN 61300 series Fibre optic interconnection devices and passive components - Basic test and measurement procedures

20、 EN 61753-2-1 Fibre optic connectors interconnecting devices and passive components performance standard - Part 2-1: Fibre optic connectors terminated on singlemode fibre for category U - Uncontrolled environments EN 61754-8 Fibre optic connector interfaces Part 8: Type CFO8 connector family ES 200

21、671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre connectors for single mode optical fibre communication systems;Common requirements and conformance testing ETS 300 019-1-3 Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunicat

22、ions equipment Part 1-3: Classification of environmental conditions; Stationary use at weatherprotected locations IEC 60793-2 Optical fibres - Part 2: Product specifications Outline and maximum dimensions: 9,4 max. 22 max. 56 max. 12,8 max. 8,2 max. 14,9max. 28,2 max.EN 50377-5-1:2003 4 CONTENTS 1 S

23、cope5 1.1 Product definition 5 1.2 Intermateability. 5 1.3 Operating environment. 5 1.4 Reliability. 5 1.5 Quality assurance 5 2 Normative references.6 3 Description7 3.1 Plug. 7 3.2 Adapter 7 3.3 Materials 7 3.4 Dimensions. 7 3.5 Colour and marking 7 4 Variants.8 4.1 Terminated plug 8 4.2 Adapter 8

24、 4.3 Identification of variants 9 5 Dimensional requirements10 5.1 Outline dimensions 10 5.1.1 Plug variants.10 5.1.2 Adapter variants12 5.2 Mating face and other limit dimensions 14 5.2.1 Plug (see Figure 5).14 5.2.2 Adapter (see Figure 6) 16 6 Tests.18 6.1 Sample size. 18 6.2 Test and measurement

25、methods . 18 6.3 Test sequence. 18 6.4 Pass/fail criteria. 18 7 Test report18 8 Testing requirements.18 8.1 Dimensional requirements 18 8.2 Optical performance requirements 19 8.3 Mechanical performance requirements. 20 8.4 Environmental performance requirements. 23 Annex A (normative) Sample size a

26、nd product sourcing requirements 26 Annex B (normative) Reference connector details.27 5 EN 50377-5-1:2003 1 Scope 1.1 Product definition This standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled sin

27、glemode EC connector set (plug adapter plug) must meet in order for it to be categorised as an EN product specification. Since different variants and grades of performance are permitted, product marking details are given in 3.5. 1.2 Intermateability All products conforming to the requirements of thi

28、s standard will intermate, the resulting level of random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will be true irrespective of the manufacturing source(s) of the product. In all cases, the intermating of plug variants having different attenu

29、ation grades will result in an uncertain level of random attenuation performance. Similarly, the intermating of plug variants with suffix A, with plug variants with suffix C, will result in an uncertain level of random attenuation performance. Table 1 Ensured level of random attenuation Plug Type/At

30、tenuation Grade EC Simplex EC Simplex tuned EC Duplex EC Duplex tuned EC Simplex P P P P EC Simplex tuned P Q P Q EC Duplex P P P P EC Duplex tuned P Q P Q 1.3 Operating environment The tests selected combined with the severities and durations are representative of an external weather protected envi

31、ronment defined by ES 200 671: external weather protected environment defined by ETS 300 019-1-3 classes 3.3, 3.4 and 3.5 EN 61753-2-1 category U: uncontrolled environment. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with

32、this standard does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this standard does not guarantee the manufacturing consistency of the product. This should be maintained using a recogn

33、ised quality assurance programme. EN 50377-5-1:2003 6 2 Normative references EN 50173 Information technology Generic cabling systems EN 60794-2 * Optical fibre cables Part 2: Indoor cables - Sectional specification EN 61300 series Fibre optic interconnection devices and passive components Basic test

34、 and measurement procedures EN 61300-2-1 Part 2-1: Tests Vibration (sinusoidal) EN 61300-2-2 Part 2-2: Tests Mating durability EN 61300-2-4 Part 2-4: Tests Fibre/cable retention EN 61300-2-5 Part 2-5: Tests Torsion/twist EN 61300-2-6 Part 2-6: Tests Tensile strength of coupling mechanism EN 61300-2-

35、7 Part 2-7: Tests Bending moment EN 61300-2-12 Part 2-12: Tests Impact EN 61300-2-17 Part 2-17: Tests Cold EN 61300-2-18 Part 2-18: Tests Dry heat High temperature endurance EN 61300-2-19 Part 2-19: Tests Damp heat (steady state) EN 61300-2-22 Part 2-22: Tests Change of temperature EN 61300-2-26 Par

36、t 2-26: Tests Salt mist EN 61300-2-27 Part 2-27: Tests Dust Laminar flow EN 61300-2-42 Part 2-42: Tests Static side load for connectors EN 61300-3-4 Part 3-4: Examinations and measurements Attenuation EN 61300-3-6 Part 3-6: Examinations and measurements Return loss EN 61300-3-34 Part 3-34: Examinati

37、ons and measurements Attenuation of random mated connectors EN 61753-2-1 Fibre optic connectors interconnecting devices and passive components performance standard Part 2-1: Fibre optic connectors terminated on single-mode fibre for category U Uncontrolled environments EN 61754-8 Fibre optic connect

38、or interfaces Part 8: Type CFO8 connector family EN 186000-1 Generic Specification: Connector sets for optical fibres and cables Part 1: Requirements, test methods and qualification approval procedures ES 200 671 Fibre optical connectors for single-mode optical fibre communication systems ETS 300 01

39、9-1-3 Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment Part 1-3: Classification of environmental conditions; Stationary use at weatherprotected locations IEC 60793-2 Optical fibres - Part 2: Product specifications IEC 61300-2-46 * Fibre op

40、tic interconnection devices and passive components - Basic test and measurement procedures - Part 2-46: Tests Damp heat (cyclic) * at draft stage 7 EN 50377-5-1:2003 3 Description The EC connector is a single position plug connector set of plug adapter plug configuration characterised by a conical,

41、spring loaded ferrule butting against an alignment sphere and a push/pull coupling mechanism. The two optical faces are in physical contact with a membrane. 3.1 Plug The plug features a metallic conical ferrule and push/pull coupling mechanism. It has a single male key which is used to limit and may

42、 be used to orientate, the relative rotation between mated connectors. A cover (dustcap) to protect the ferrule endface when the connector is in the unmated condition shall be provided. 3.2 Adapter The adapter has a metallic alignment sphere with a membrane fixed into it. The mounting style can be r

43、ectangular flange - simplex, rectangular flange - duplex. Covers (dustcaps) shall be provided to protect each port of the adapter. 3.3 Materials Materials which are not specified or which are not specifically described are left to the discretion of the manufacturer. 3.4 Dimensions Outline dimensions

44、 and other dimensions necessary to ensure intermateability or which affect performances are specified. All other dimensions are left to the discretion of the manufacturer. Where the mating face limit dimensions are not in agreement with an IEC Interface Standard this is clearly stated. 3.5 Colour an

45、d marking Marking of the product shall be in accordance with 2.6.2 of EN 186000-1 in the following order of precedence: a) identification of manufacturer; b) manufacturing date code : year/week. The following colour scheme is preferred: the colour of the delatch housing, and of the adapter shall be

46、Green according to PANTONE 375 C; the boot can be used for coding inside the colours listed in Table 2. EN 50377-5-1:2003 8 Table 2 Preferred colour scheme for the boot Colour PANTONE Grey 2 U Red 187 C Blue 3015 C Green 375 C 4 Variants 4.1 Terminated plug The defined fibre/cable variants are given

47、 in Table 3: Table 3 Plug variants Variant No. Fibre/Cable mm Structure Notes A01 0,9 Buffered fibre Simplex, untuned A02 1,6 Tube Simplex, untuned A03 2,8 0,2 Reinforced cable Simplex, untuned A04 0,9 Buffered fibre Duplex, untuned A05 1,6 Tube Duplex, untuned A06 2,8 0,2 Reinforced cable Duplex, u

48、ntuned B01 0,9 Buffered fibre Simplex, tuned B02 1,6 Tube Simplex, tuned B03 2,8 0,2 Reinforced cable Simplex, tuned B04 0,9 Buffered fibre Duplex, tuned B05 1,6 Tube Duplex, tuned B06 2,8 0,2 Reinforced cable Duplex, tuned 4.2 Adapter The defined adapter variants are given in Table 4: Table 4 Adapt

49、er variants Variant No. Format D01, D03 Rectangular flange - simplex D02, D04 Rectangular flange - duplex 9 EN 50377-5-1:2003 4.3 Identification of variants The identification numbers for the fibre/cable variants and adapter variants with fibre category IEC 60793-2 are given in Tables 5 and 6. Table 5 Plug variants Variant numbe