1、BSI Standards PublicationSpecifications for particular types of winding wiresPart 21: Solderable polyurethane enamelled round copper wire overcoated with polyamide, class 155BS EN 60317-21:2014National forewordThis British Standard is the UK implementation of EN 60317-21:2014. It isidentical to IEC
2、60317-21:2013. It supersedes BS EN 60317-21:1996 which iswithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/55, Winding wires.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to i
3、nclude all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 75753 2ICS 29.060.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This B
4、ritish Standard was published under the authority of theStandards Policy and Strategy Committee on 28 February 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60317-21:2014EUROPEAN STANDARD EN 60317-21 NORME EUROPENNE EUROPISCHE NORM February 2014CENELEC Eu
5、ropean Committee for Electrotechnical StandardizationComit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2014 CENELEC - All rights of exploitation in any form and by any means reserved worl
6、dwide for CENELEC members. Ref. No. EN 60317-21:2014 E ICS 29.060.10 Supersedes EN 60317-21:1995 + A1:1998 + A2:2000 English version Specifications for particular types of winding wires - Part 21: Solderable polyurethane enamelled round copper wire overcoatedwith polyamide, class 155 (IEC 60317-21:2
7、013) Spcifications pour types particuliers defils de bobinage - Partie 21: Fil brasable de section circulaireen cuivre maill avec polyurthane etavec surcouche polyamide, classe 155(CEI 60317-21:2013) Technische Lieferbedingungen frbestimmte Typen von Wickeldrhten - Teil 21: Runddrhte aus Kupfer,verz
8、innbar, lackisoliert mit Polyurethanund darber mit Polyamid, Klasse 155(IEC 60317-21:2013) This European Standard was approved by CENELEC on 2013-11-14. CENELEC members are bound to complywith the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standardthe st
9、atus of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained onapplication to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, Frenc
10、h, German). A version in any otherlanguage made by translation under the responsibility of a CENELEC member into its own language and notifiedto the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Be
11、lgium, Bulgaria, Croatia, Cyprus,the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,
12、 Switzerland, Turkey and the United Kingdom. Foreword The text of document 55/1412/FDIS, future edition 3 of IEC 60317-21, prepared by IEC/TC 55 “Winding wires“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60317-21:2014. The following dates are fixed: latest date by w
13、hich the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-08-14 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-11-14 This document supersedes EN 60317-21:1995. EN
14、60317-21:2014 includes the following significant technical changes with respect to EN 60317-21:1995: new 3.2.2 containing general notes on winding wire, formerly a part of the scope; revision to references to EN 60317-0-1: 2014 to clarify that their application is normative; consolidation of 17.1 an
15、d 17.2 of the solderability requirements; modification to Clause 19, Dielectric dissipation factor; new Clause 23, Pin hole test. The numbering of clauses in this standard is not continuous from Clauses 20 and 30 in order to reserve space for possible future wire requirements prior to those for wire
16、 packaging. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60317-21:201
17、3 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60264 Series NOTE Harmonized as EN 60264 Series (not modified). IEC 60317 Series NOTE Harmonized as EN 60317 Ser
18、ies (not modified). IEC 60851 Series NOTE Harmonized as EN 60851 Series (not modified). BS EN 60317-21:2014 EN 60317-21:2014Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normati
19、vely referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by comm
20、on modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60317-0-1 2013 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire EN 60317-0-1 2014 BS EN 60317-21:2014 EN 60317-21:2014 2 60317-21
21、 IEC:2013 CONTENTS INTRODUCTION . 5 1 Scope . 6 2 Normative references . 6 3 Terms, definitions, general notes and appearance 6 3.1 Terms and definitions 6 3.2 General notes 6 3.2.1 Methods of test 6 3.2.2 Winding wire 6 3.3 Appearance . 7 4 Dimensions 7 5 Electrical resistance . 7 6 Elongation 7 7
22、Springiness 7 8 Flexibility and adherence 7 9 Heat shock . 7 10 Cut-through 7 11 Resistance to abrasion (nominal conductor diameters from 0,250 mm up to and including 1,600 mm) . 7 12 Resistance to solvents 8 13 Breakdown voltage . 8 13.1 General . 8 13.2 Nominal conductor diameters up to and includ
23、ing 0,100 mm 8 13.3 Nominal conductor diameters over 0,100 mm up to and including 1,600 mm . 9 14 Continuity of insulation . 10 15 Temperature index . 10 16 Resistance to refrigerants . 11 17 Solderability . 11 17.1 Nominal conductor diameters up to and including 0,100 mm 11 17.2 Nominal conductor d
24、iameters over 0,100 mm 11 18 Heat or solvent bonding 11 19 Dielectric dissipation factor . 11 20 Resistance to transformer oil 11 21 Loss of mass 11 23 Pin hole test . 11 30 Packaging 11 Bibliography 12 Table 1 Resistance to abrasion 8 Table 2 Breakdown voltage 9 Table 3 Breakdown voltage 10 BS EN 6
25、0317-21:2014 EN 60317-21:201460317-21 IEC:2013 5 INTRODUCTION This part of IEC 60317 is one of a series which deals with insulated wires used for windings in electrical equipment. The series has three groups describing: 1) Winding wires Test methods (IEC 60851); 2) Specifications for particular type
26、s of winding wires (IEC 60317); 3) Packaging of winding wires (IEC 60264). BS EN 60317-21:2014 EN 60317-21:2014 6 60317-21 IEC:2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES Part 21: Solderable polyurethane enamelled round copper wire overcoated with polyamide, class 155 1 Scope This part
27、 of IEC 60317 specifies the requirements of solderable enamelled round copper winding wire of class 155 with a dual coating. The underlying coating is based on polyurethane resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requ
28、irements. The superimposed coating is based on polyamide resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is
29、: Grade 1: 0,050 mm up to and including 1,600 mm; Grade 2: 0,050 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are
30、indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60317-0-1:2013, Specifications for particular types of winding wires Part 0-1: General requirements E
31、namelled round copper wire 3 Terms, definitions, general notes and appearance 3.1 Terms and definitions Subclause 3.1 of IEC 60317-0-1:2013 applies. 3.2 General notes 3.2.1 Methods of test Subclause 3.2.1 of IEC 60317-0-1:2013 applies. In case of inconsistencies between IEC 60317-0-1:2013 and this p
32、art of IEC 60317, the latter shall prevail. 3.2.2 Winding wire Class 155 is a thermal class that requires a minimum temperature index of 155 and a heat shock temperature of at least 175 C. The temperature in C corresponding to the temperature index is not necessarily that at which it is recommended
33、that the wire be operated and this will depend on many factors, including the type of equipment involved. BS EN 60317-21:2014 EN 60317-21:201460317-21 IEC:2013 7 3.3 Appearance Subclause 3.3 of IEC 60317-0-1:2013 applies. 4 Dimensions Clause 4 of IEC 60317-0-1:2013 applies. 5 Electrical resistance C
34、lause 5 of IEC 60317-0-1:2013 applies. 6 Elongation Clause 6 of IEC 60317-0-1:2013 applies. 7 Springiness Clause 7 of IEC 60317-0-1:2013 applies. 8 Flexibility and adherence Clause 8 of IEC 60317-0-1:2013 applies. For 8.4, the constant K used for the calculation of the number of revolutions for the
35、peel test shall be 150 mm. 9 Heat shock Clause 9 of IEC 60317-0-1:2013 applies. The minimum heat shock temperature shall be 175 C. 10 Cut-through No failure shall occur within 2 min at 200 C. 11 Resistance to abrasion (nominal conductor diameters from 0,250 mm up to and including 1,600 mm) The wire
36、shall meet the requirements given in Table 1. For intermediate nominal conductor diameters, the value of the next larger nominal conductor diameter shall be taken. BS EN 60317-21:2014 EN 60317-21:2014 8 60317-21 IEC:2013 Table 1 Resistance to abrasion Nominal conductor diameter Grade 1 Grade 2 Minim
37、um average force to failure Minimum force to failure of each measurement Minimum average force to failure Minimum force to failure of each measurement mm N N N N 0,250 2,30 1,95 4,10 3,50 0,280 2,50 2,10 4,40 3,70 0,315 2,70 2,30 4,75 4,00 0,355 2,90 2,50 5,10 4,30 0,400 3,15 2,70 5,45 4,60 0,450 3,
38、40 2,90 5,80 4,90 0,500 3,65 3,10 6,20 5,25 0,560 3,90 3,30 6,65 5,60 0,630 4,20 3,55 7,1 6,00 0,710 4,50 3,80 7,60 6,45 0,800 4,80 4,10 8,10 6,90 0,900 5,20 4,40 8,70 7,40 1,000 5,60 4,75 9,30 7,90 1,120 6,00 5,15 10,0 8,50 1,250 6,50 5,55 10,7 9,10 1,400 7,00 5,95 11,4 9,70 1,600 7,50 6,35 12,2 10
39、,4 12 Resistance to solvents Clause 12 of IEC 60317-0-1:2013 applies. 13 Breakdown voltage 13.1 General The wire shall meet the requirements given in 13.2 and 13.3, respectively, when tested at room temperature and at 155 C when this is required by the purchaser. 13.2 Nominal conductor diameters up
40、to and including 0,100 mm At least four of the five specimens tested shall not break down at a voltage less than or equal to that given in Table 2. For intermediate nominal conductor diameters, the value of the next larger nominal conductor diameter shall be taken. BS EN 60317-21:2014 EN 60317-21:20
41、1460317-21 IEC:2013 9 Table 2 Breakdown voltage Nominal conductor diameter mm Minimum breakdown voltage (root-mean-square value) (r.m.s) V Grade 1 Grade 2 At room temperature 0,050 275 550 0,056 300 600 0,063 350 650 0,071 375 650 0,080 375 750 0,090 450 800 0,100 450 850 13.3 Nominal conductor diam
42、eters over 0,100 mm up to and including 1,600 mm At least four of the five specimens tested shall not break down at a voltage less than or equal to that given in Table 3. For intermediate nominal conductor diameters, the value of the next larger nominal conductor diameter shall be taken. BS EN 60317
43、-21:2014 EN 60317-21:2014 10 60317-21 IEC:2013 Table 3 Breakdown voltage Nominal conductor diameter mm Minimum breakdown voltage (r.m.s) V Grade 1 Grade 2 Room temperature 155 C Room temperature 155 C 0,112 1 200 0 900 2 400 1 800 0,125 1 300 1 000 2 500 1 900 0,140 1 400 1 100 2 700 2 000 0,160 1 5
44、00 1 100 2 900 2 200 0,180 1 500 1 100 3 000 2 300 0,200 1 600 1 200 3 100 2 300 0,224 1 700 1 300 3 300 2 500 0,250 1 900 1 400 3 500 2 600 0,280 2 000 1 500 3 600 2 700 0,315 2 000 1 500 3 700 2 800 0,355 2 100 1 600 3 900 2 900 0,400 2 100 1 600 4 000 3 000 0,450 2 100 1 600 4 000 3 000 0,500 2 2
45、00 1 700 4 100 3 100 0,560 2 200 1 700 4 100 3 100 0,630 2 300 1 700 4 300 3 200 0,710 2 300 1 700 4 300 3 200 0,800 2 300 1 700 4 400 3 300 0,900 2 400 1 800 4 500 3 400 1,000 up to and including 1,600 2 400 1 800 4 500 3 400 14 Continuity of insulation Clause 14 of IEC 60317-0-1:2013 applies. 15 T
46、emperature index Clause 15 of IEC 60317-0-1:2013 applies. The minimum temperature index shall be 155. BS EN 60317-21:2014 EN 60317-21:201460317-21 IEC:2013 11 16 Resistance to refrigerants Test inappropriate. 17 Solderability 17.1 Nominal conductor diameters up to and including 0,100 mm The temperat
47、ure of the solder bath shall be (390 5) C. The maximum immersion time shall be 2 s. The surface of the tinned wire shall be smooth and free from holes and enamel residues. 17.2 Nominal conductor diameters over 0,100 mm The temperature of the solder bath shall be (390 5) C. The maximum immersion time
48、 (in seconds) shall be the following multiple of the nominal conductor diameter (in millimetres) with a minimum of 2 s. Grade 1 Grade 2 8 s/mm 12 s/mm The surface of the tinned wire shall be smooth and free from holes and enamel residues. 18 Heat or solvent bonding Test inappropriate. 19 Dielectric
49、dissipation factor Test to be agreed between purchaser and supplier. 20 Resistance to transformer oil Test inappropriate. 21 Loss of mass Test inappropriate. 23 Pin hole test Clause 23 of IEC 60317-0-1:2013 applies. 30 Packaging Clause 30 of IEC 60317-0-1:2013 applies. BS EN 60317-21:2014 EN 60317-21:2014 12 60317-21 IEC:2013 Bibliography IEC 60264 (all parts), Packaging of winding wires IEC 60317 (all parts), Specifications for particular types of winding wires