EN 60966-2-2-2003 en Radio frequency and coaxial cable assemblies Part 2-2 Blank detail specification for flexible coaxial cable assemblies《射频和同轴电缆组件 第2-2部分 软同轴电缆组件空白详细规范 IEC 60966.pdf

上传人:towelfact221 文档编号:719213 上传时间:2019-01-04 格式:PDF 页数:12 大小:333.95KB
下载 相关 举报
EN 60966-2-2-2003 en Radio frequency and coaxial cable assemblies Part 2-2 Blank detail specification for flexible coaxial cable assemblies《射频和同轴电缆组件 第2-2部分 软同轴电缆组件空白详细规范 IEC 60966.pdf_第1页
第1页 / 共12页
EN 60966-2-2-2003 en Radio frequency and coaxial cable assemblies Part 2-2 Blank detail specification for flexible coaxial cable assemblies《射频和同轴电缆组件 第2-2部分 软同轴电缆组件空白详细规范 IEC 60966.pdf_第2页
第2页 / 共12页
EN 60966-2-2-2003 en Radio frequency and coaxial cable assemblies Part 2-2 Blank detail specification for flexible coaxial cable assemblies《射频和同轴电缆组件 第2-2部分 软同轴电缆组件空白详细规范 IEC 60966.pdf_第3页
第3页 / 共12页
EN 60966-2-2-2003 en Radio frequency and coaxial cable assemblies Part 2-2 Blank detail specification for flexible coaxial cable assemblies《射频和同轴电缆组件 第2-2部分 软同轴电缆组件空白详细规范 IEC 60966.pdf_第4页
第4页 / 共12页
EN 60966-2-2-2003 en Radio frequency and coaxial cable assemblies Part 2-2 Blank detail specification for flexible coaxial cable assemblies《射频和同轴电缆组件 第2-2部分 软同轴电缆组件空白详细规范 IEC 60966.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 60966-2-2:2003 Radio frequency and coaxial cable assemblies Part 2-2: Blank detail specification for flexible coaxial cable assemblies The European Standard EN 60966-2-2:2003 has the status of a British Standard ICS 33.120.10 BS EN 60966-2-2:2003 This British Standard was publ

2、ished under the authority of the Standards Policy and Strategy Committee on 17 November 2003 BSI 17 November 2003 ISBN 0 580 42919 9 National foreword This British Standard is the official English language version of EN 60966-2-2:2003. It is identical with IEC 60966-2-2:2003. It supersedes BS EN 609

3、66-2-2:1996 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories, to Subcommittee EPL/46/1, Coaxial cables, which has the responsibility to: A list of

4、 organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standard

5、s Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard do

6、es not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and p

7、romulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 9 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Dat

8、e CommentsEUROPEAN STANDARD EN 60966-2-2 NORME EUROPENNE EUROPISCHE NORM October 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Bru

9、ssels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60966-2-2:2003 E ICS 33.120.10 Supersedes EN 60966-2-2:1994English version Radio frequency and coaxial cable assemblies Part 2-2: Blank detail specification for flexible c

10、oaxial cable assemblies (IEC 60966-2-2:2003) Ensembles de cordons coaxiaux et de cordons pour frquences radiolectriques Partie 2-2: Spcification particulire cadre pour cordons coaxiaux souples (CEI 60966-2-2:2003) Konfektionierte Koaxial- und Hochfrequenzkabel Teil 2-2: Vordruck fr Bauartspezifikati

11、on fr flexible konfektionierte Koaxialkabel (IEC 60966-2-2:2003) This European Standard was approved by CENELEC on 2003-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national stand

12、ard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any othe

13、r language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland,

14、France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 60966-2-2:2003 - 2 - Foreword The text of document 46A/546/FDIS, future edition 2 of IEC 60966-2-2, prepared by SC 46A,

15、Coaxial cables, of IEC TC 46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60966-2-2 on 2003-10-01. This European Standard supersedes EN 60966-2-2:1994. The major ch

16、ange with respect to EN 60966-2-2:1994 is the reference to the 1999 edition of the generic specification EN 60966-1. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2004-07-01

17、 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2006-10-01 This blank detail specification is to be read with EN 60966-1:1999, Radio frequency and coaxial cable assemblies Part 1: Generic specification - General requirements and test methods and with E

18、N 60966-2-1:2003, Radio frequency and coaxial cable assemblies Part 2-1: Sectional specification for flexible coaxial cable assemblies. _ Endorsement notice The text of the International Standard IEC 60966-2-2:2003 was approved by CENELEC as a European Standard without any modification. _ Page2 EN60

19、96622:200360966-2-2 IEC:2003 3 INTRODUCTION This part of IEC 60966 is a blank detail specification that relates to flexible coaxial cable assemblies operating in the transverse electromagnetic mode (TEM). The creation of a uniform layout and style of detail specifications is determined by the use of

20、 a blank detail specification pro forma. The detail specification may be prepared by the insertion of data into the pro forma by a national standards organization, by an approved manufacturer or by a user (when prepared by a user, the detail specification shall be submitted to the national authorize

21、d institution by an approved manufacturer). Instructions to complete a blank detail specification Detail specifications shall, as far as possible, be written in accordance with the pro forma which has a front page with a general description and a drawing or isometric sketch of the cable assembly and

22、 its possible variants; ratings, characteristics and inspection requirements (those which are not required or specified shall be omitted). Under quality assessment, tests are divided into groups. Whenever possible entire groups shall be either specified or omitted. These groups are: Ba (Basic) Visua

23、l and dimensional tests Eb (Electrical basic) Low-frequency operational tests Eh (Electrical high frequency) High-frequency tests Ep (Electrical phase) Electrical length tests Ee (Electrical screening effectiveness) Screening effectiveness tests Ez (Electrical impedance Z) Impedance uniformity tests

24、 Et (Electrical transmission) Power rating test Mn (Mechanical) Mechanical tests Vc (Environmental climatic) Climatic tests Vv (Environmental vibration) Vibration, bumps and shock tests Vt (Environmental temperature) Humidity, rapid change of temperature and chemical tests Vf (Environmental flammabi

25、lity) Flammability, dust and water immersion tests Page3 EN6096622:200360966-2-2 IEC:2003 4 The numbers shown in brackets on this page correspond to the following items of required information, which should be entered in the spaces provided. 1 Name and address of the organization that has prepared t

26、he document. 2 IEC document number, issue number and date of issue. 3 Address of the organization from which the document is available. 4 Related documents. 5 Any other reference to the cable assembly, national reference, trade name, etc. 6 A drawing of the cable assembly giving the outline and prin

27、cipal dimensions. The dimensions are considered to be in millimetres unless otherwise specified. NOTE The symbol “l” may be used to specify the cable length. In this case the detail specification covers cable assemblies of any length and “l” should then be specified in the order. 7 Nominal character

28、istic impedance of the cable assembly. 8 Frequency range of use of the cable assembly. (DC may be used as a lower limit of frequency, indicating that the cable assembly is capable of transmitting d.c., but at d.c. a number of characteristics may neither apply nor be verified by inspection.) 9 Weight

29、, function of the length of the cable assembly. 10 Minimum static inside bending radius of the cable assembly. Also minimum dynamic inside bending radius of the cable assembly, i.e. the bending radius used for the insertion loss and stability of electrical length tests. 11 Climatic category of the c

30、able assembly related to IEC 60068. 12 The applicable quality assessment test groups according to Table 1 of the sectional specification (for example, Ba, Eh, Eb). 13 Description, if applicable, of the components used for the manufacture of the cable assembly. 14 Variants of the cable assembly may b

31、e listed in one detail specification. The variants may differ by colour, connector material, connector sex or type. (Inspection for quality conformance will be the same for all variants whereas the ratings and characteristics can change.) 15 Number of pages of the blank detail specification includin

32、g the annexes. 16 Ratings and characteristics of the cable assembly. The properties not specified shall be omitted. 17 Reference to the appropriate subclause in the sectional and generic specifications. 18 The value either guaranteed or used for the defined test. 19 All information required by the s

33、ectional specification and any remarks considered as important for understanding the test. Page4 EN6096622:200360966-2-2 IEC:2003 5 20 Test groups (corresponding to box 12 on page 1 of the blank detail specification). 21 Name of test and its subclause number in the sectional and generic specificatio

34、ns. 22 Periodicity of the test. The periodic tests apply only in the case of qualification approval. 23 Inspection level selected from IEC 60410. 24 Acceptable quality level selected from IEC 60410. 25 Sample size. 26 Acceptance criteria. 27 Test specimen length shall be specified if the length is d

35、ifferent to that given in box 6 on page 1 of the blank detail specification or if the length in box 6 is left free with the parameter “l”. Page5 EN6096622:200360966-2-2 IEC:2003 6 1 Prepared by: 2 Document no.: Issue: Date: 3 Available from: 4 Generic specification: IEC 60966-1 Sectional specificati

36、on: IEC 60966-2-1 Blank detail specification: IEC 60966-2-2 5 Additional references: Detail specification for a flexible coaxial cable assembly 6 7 Characteristic impedance: 8 Frequency range: to GHz 9 Weight: g+ g/m 10 Minimum inside radius for static bending: mm for dynamic bending: mm 11 Climatic

37、 category: / 12 Applicable test groups: Ba, Eh, Eb, Ez, Ep, Ee, Mn, Vv, Vc, Vt, Vf. 13 Connector reference number Series type sex of the connector Reference no. type of the cable Additional armour Marking method Marking text 14 Variants: 15 Page 1 of 7 pages Page6 EN6096622:200360966-2-2 IEC:2003 7

38、16 17 18 19 Inspection values, ratings or characteristics Subclause Value Remarks Electrical* Reflection properties 8.1 dB to GHz From one or two ends Uniformity of impedance 8.2 . . Rise time of pulse ps Insertion loss 8.3 . dB . dB/m to GHz Insertion loss stability 8.4 . dB to GHz Radius of mandre

39、l Bending test method 1 or 2 (see also 8.4.4) Propagation time 8.5 . ns . ns/m Frequency or rise time Stability of electrical length 8.6 /GHz to GHz Cycles bent Cycles twisted Phase difference 8.7 + . /GHz Frequency Phase variation with temperature 8.8 . /GHz to K to GHz Screening effectiveness 8.9

40、. m to MHz Voltage proof 8.10 . kV Insulation resistance 8.11 . M Test voltage V Inner and outer conductor continuity 8.12 OK / no Voltage Current Frequency Power rating 8.14 . W Mechanical* Tensile 9.1 Interface OK/no Force N Duration s Return loss dB Flexure 9.2 Interface OK/no Force N Flexing end

41、urance 9.3 Interface OK/no Return loss dB Cable crushing 9.4 Interface OK/no Force N Return loss dB Page7 EN6096622:200360966-2-2 IEC:2003 8 16 17 18 19 Inspection values, ratings or characteristics Subclause Value Remarks Environmental* Vibration 10.2 OK/no m/s 2 to Hz g (see also 10.2.1.3) Bumps 1

42、0.2 OK/no m/s 2 g Shock 10.2 OK/no m/s 2 sine ns g Climatic sequence 10.3 ././. Cycles (connectors (un-) mated Tests: 7.2, 8.3, 8.10, 8.11 Damp heat, steady state 10.4 OK/no Cycles Days (connectors (un-) mated Tests: Rapid change of temperature 10.5 OK/no K/+ K Cycles Tests: 7.2, 8.3, 8.10, 8.11 Sol

43、vents and contaminating fluids 10.6 OK/no Cycles (connectors (un-) mated Tests: 7.2, 8.3, 8.11 Water immersion 10.7 OK/no Salt mist and sulphur dioxide 10.8 OK/no Dust tests 10.9 OK/no Flammability 10.10 OK/no * If appropriate, values may be given for each variant. Page8 EN6096622:200360966-2-2 IEC:

44、2003 9 Grouping of tests for specification purposes Recommended grouping of tests Recommended severities 20 21 22 23 24 25 26 Group Subclause Tests Periodicity IL AQL n c 27 Specimen length 7.2 Visual inspection Ba 7.3 Dimensional inspection 8.1 Reflection properties Eh 8.3 Insertion loss 8.10 Volta

45、ge proof 8.11 Insulation resistance Eb 8.12 Inner and outer conductor continuity Ez 8.2 Uniformity of impedance 8.5 Propagation time 8.6 Stability of electrical length 8.7 Phase difference Ep 8.8 Phase variation with temperature Ee 8.9 Screening effectiveness 9.1 Tensile 9.2 Flexure 9.3 Flexing endu

46、rance Mn 9.4 Cable crushing Vv 10.2 Vibration, bumps and shock Vc 10.3 Climatic sequence 10.4 Damp heat, steady state 10.5 Rapid change of temperature Vt 10.8 Salt mist and sulphur dioxide 10.7 Water immersion Vf 10.9 Dust tests 10.10 Flammability The periodic tests above apply only in the case of q

47、ualification approval. In the case of capability approval the tests may be performed on the applicable CQCs (capability qualification components) instead. _ Page9 EN6096622:2003BS EN 60966-2-2:2003 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent nati

48、onal body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the lat

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1