EN 61169-52-2015 en Radio-frequency connectors - Part 52 Sectional specification for series MMCX RF coaxial connectors.pdf

上传人:ideacase155 文档编号:719684 上传时间:2019-01-04 格式:PDF 页数:32 大小:1.33MB
下载 相关 举报
EN 61169-52-2015 en Radio-frequency connectors - Part 52 Sectional specification for series MMCX RF coaxial connectors.pdf_第1页
第1页 / 共32页
EN 61169-52-2015 en Radio-frequency connectors - Part 52 Sectional specification for series MMCX RF coaxial connectors.pdf_第2页
第2页 / 共32页
EN 61169-52-2015 en Radio-frequency connectors - Part 52 Sectional specification for series MMCX RF coaxial connectors.pdf_第3页
第3页 / 共32页
EN 61169-52-2015 en Radio-frequency connectors - Part 52 Sectional specification for series MMCX RF coaxial connectors.pdf_第4页
第4页 / 共32页
EN 61169-52-2015 en Radio-frequency connectors - Part 52 Sectional specification for series MMCX RF coaxial connectors.pdf_第5页
第5页 / 共32页
点击查看更多>>
资源描述

1、BSI Standards PublicationRadio-Frequency ConnectorsPart 52: Sectional specification for series MMCX RF coaxial connectorsBS EN 61169-52:2015National forewordThis British Standard is the UK implementation of EN 61169-52:2015. It isidentical to IEC 61169-52:2015. It supersedes BS EN 122340:2002 which

2、iswithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained onrequest to its secretary.T

3、his publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 85603 7ICS 33.120.30Compliance with a British Standard cannot confer

4、immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 October 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61169-52:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM

5、 EN 61169-52 October 2015 ICS 33.120.30 Supersedes EN 122340:2002 English Version Radio-frequency connectors - Part 52: Sectional specification for series MMCX RF coaxial connectors (IEC 61169-52:2015) Connecteurs pour frquences radiolectriques - Partie 52: Spcification intermdiaire relative aux con

6、necteurs coaxiaux pour frquences radiolectriques srie MMCX (IEC 61169-52:2015) Hochfrequenz-Steckverbinder - Teil 52: Rahmenspezifikation fr koaxiale HF-Steckverbinder der Serie MMCX (IEC 61169-52:2015) This European Standard was approved by CENELEC on 2015-07-10. CENELEC members are bound to comply

7、 with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC M

8、anagement Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has

9、the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latv

10、ia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrot

11、echnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61169-52:2015 E BS EN 61169-52:2015EN 61169-52:2015 2 European foreword The text of document 46F

12、/314/FDIS, future edition 1 of IEC 61169-52, prepared by SC 46F “R.F. and microwave passive components“ of IEC/TC 46 “Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61169-

13、52:2015. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-04-10 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2

14、018-07-10 This document supersedes EN 122340:2002. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the

15、International Standard IEC 61169-52:2015 was approved by CENELEC as a European Standard without any modification. BS EN 61169-52:2015EN 61169-52:2015 3 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in w

16、hole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publica

17、tion has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 60068-1 - Environmental testing

18、- Part 1: General and guidance EN 60068-1 - IEC 61169-1 2013 Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods EN 61169-1 2013 IEC 62037 Series Passive RF and microwave devices, intermodulation level measurement EN 62037 Series BS EN 61169-52:201

19、5 2 IEC 61169-52:2015 IEC 2015 CONTENTS FOREWORD . 4 1 Scope 6 2 Normative references. 6 3 Mating face and gauge information . 6 3.1 Dimensions General connectors Grade 2 . 6 3.1.1 Connector with pin centre contact . 6 3.1.2 Connector with socket centre contact . 7 3.2 Gauges . 8 3.2.1 Gauge pin for

20、 socket centre contact . 8 3.2.2 Gauge for outer contact 9 3.3 Dimensions Standard test connectors Grade 0 . 11 3.3.1 Connector with pin centre contact . 11 3.3.2 Connector with socket centre contact . 12 4 Quality assessment procedure . 13 4.1 General . 13 4.2 Rating and characteristics (see Clause

21、 5 of IEC 61169-1:2013) 13 4.3 Test schedule and inspection requirements 15 4.3.1 Acceptance tests 15 4.3.2 Periodic tests . 16 4.4 Procedures for the qualification approval . 18 4.4.1 Quality conformance inspection 18 4.4.2 Qualification approval and its maintenance . 18 5 Instructions for preparat

22、ion of detail specifications (DS) . 18 5.1 General . 18 5.2 Identification of the component 18 5.3 Performances 19 5.4 Marking, ordering information and related matters 19 5.5 Selection of tests, test conditions and severities 19 5.6 Blank detail specification pro-forma for type MMCX connector 20 6

23、Marking . 24 6.1 Marking of component . 24 6.2 Marking and contents of package 24 Figure 1 Connector with pin centre contact . 7 Figure 2 Connector with socket centre contact 8 Figure 3 Gauge pin for socket centre contact 9 Figure 4 Gauge for outer contact 10 Figure 5 Connector with pin centre conta

24、ct . 11 Figure 6 Connector with socket centre contact 12 Table 1 Dimensions of connector with pin centre contact 7 Table 2 Dimensions of connector with socket centre contact . 8 Table 3 Dimensions of gauge pin for socket centre contact . 9 Table 4 Dimensions of gauge for outer contact . 10 Table 5 D

25、imensions of connector with pin centre contact 11 BS EN 61169-52:2015IEC 61169-52:2015 IEC 2015 3 Table 6 Dimensions of connector with socket centre contact . 12 Table 7 Preferred climatic categories (see IEC 60068-1) . 13 Table 8 Rating and characteristics 13 Table 9 Acceptance tests . 16 Table 10

26、Periodic tests 16 BS EN 61169-52:2015 4 IEC 61169-52:2015 IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ RADIO-FREQUENCY CONNECTORS Part 52: Sectional specification for series MMCX RF coaxial connectors FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization

27、 for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC pub

28、lishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may

29、 participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreeme

30、nt between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Pub

31、lications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or

32、 for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corres

33、ponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for a

34、ny services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and

35、IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Att

36、ention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights.

37、IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61169-52 has been prepared by subcommittee 46F: R.F. and microwave passive components, of IEC technical committee 46: Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive com

38、ponents and accessories The text of this standard is based on the following documents: FDIS Report on voting 46F/314/FDIS 46F/320/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted

39、in accordance with the ISO/IEC Directives, Part 2. A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors, can be found on the IEC website. BS EN 61169-52:2015IEC 61169-52:2015 IEC 2015 5 The committee has decided that the contents of this publication will r

40、emain unchanged until the stability date indicated on the IEC website under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of this publication may be

41、 issued at a later date. IMPORTANT The colour inside logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print this document using a colour printer. BS EN 61169-52:2015 6

42、 IEC 61169-52:2015 IEC 2015 RADIO-FREQUENCY CONNECTORS Part 52: Sectional specification for series MMCX RF coaxial connectors 1 Scope This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial conne

43、ctors with snap-on coupling, typically for use in 50 cable networks (MMCX). It prescribes mating face dimensions for general purpose connectors grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specific

44、ations relating to series MMCX RF connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The MMCX miniature snap-on coupling structur

45、e series R.F. coaxial connector with the characteristic of normative impedance 50 are used with various kinds of R.F cables and strips. The operating frequency limit is up to 6 GHz. NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose on

46、ly. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any a

47、mendments) applies. IEC 61169-1:2013, Radio frequency connectors Part 1: Generic specification General requirements and measuring methods IEC 60068-1, Environmental testing Part 1: General and guidance IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement 3 Matin

48、g face and gauge information 3.1 Dimensions General connectors Grade 2 3.1.1 Connector with pin centre contact The mating face of connector with pin centre contact is shown in Figure 1 and its dimensions are shown in Table 1. BS EN 61169-52:2015IEC 61169-52:2015 IEC 2015 7 NOTE Mechanical and electr

49、ical reference plane. Figure 1 Connector with pin centre contact Table 1 Dimensions of connector with pin centre contact Ref. mm Min. Max. a 2,35 2,40 b 1,80 - c 1,58 1,62 d - 2,83 f - 0,20 g 0,38 0,42 h 0,00 0,25 ia1,23 - jb2,08 2,12 k 2,70 - 30 - aThe dimension should meet the mechanical and electrical requirements, also compensate the electrical effect caused by gaps. bThe shape of elastic gasket is optional and its diameter

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1