1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationFibre optic interconnectingdevices and passive components Basic test and measurement proceduresPart 3-46: Measurement Bore diameter for guide pin in MT ferrulesBS EN 61300-3-46:2
2、011National forewordThis British Standard is the UK implementation of EN 61300-3-46:2011. It isidentical to IEC 61300-3-46:2011.The UK participation in its preparation was entrusted by Technical CommitteeGEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnectingdevices and passive c
3、omponents.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 67195 1ICS 33.180.20Compliance
4、with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 August 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61300-3-46:2011EUROPEAN STA
5、NDARD EN 61300-3-46 NORME EUROPENNE EUROPISCHE NORM August 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All r
6、ights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-3-46:2011 E ICS 33.180.20 English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-46: Measurement - Bore diameter for guide
7、 pin in MT ferrules (IEC 61300-3-46:2011) Dispositifs dinterconnexion et composantspassifs fibres optiques - Mthodes fondamentales dessais et de mesures - Partie 3-46: Mesure - Diamtre dalsage pour broche de guidage dans les frules MT (CEI 61300-3-46:2011) Lichtwellenleiter -Verbindungselemente und
8、passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 3-45: Messung - Bohrlochdurchmesser fr Fhrungsstifte von Mehrfasersteckverbindern (IEC 61300-3-46:2011) This European Standard was approved by CENELEC on 2011-07-21. CENELEC members are bound to comply with the CEN/CENELEC Internal Regula
9、tions which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This
10、 European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members
11、 are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia,
12、Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61300-3-46:2011EN 61300-3-46:2011 - 2 - Foreword The text of document 86B/3076/CDV, future edition 1 of IEC 61300-3-46, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was s
13、ubmitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-3-46 on 2011-07-21. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such pa
14、tent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-04-21 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-07-
15、21 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61300-3-46:2011 was approved by CENELEC as a European Standard without any modification. _ BS EN 61300-3-46:2011- 3 - EN 61300-3-46:2011 Annex ZA (normative) Normative references to international p
16、ublications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments)
17、 applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 61300-3-1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1:
18、 Examinations and measurements - Visual examination EN 61300-3-1 - IEC 61754-5 - Fibre optic connector interfaces - Part 5: Type MT connector family EN 61754-5 - BS EN 61300-3-46:2011 2 61300-3-46 IEC:2011 CONTENTS 1 Scope . 5 2 Normative references . 5 3 General description 5 3.1 Pin specifications
19、 5 3.2 Test conditions 6 3.3 Apparatus 6 4 Procedure 6 5 Post test examination . 8 6 Details to be specified 8 Figure 1 Gauge pin through ferrule 7 Figure 2 An example of a complete measurement apparatus with ferrule . 7 Figure 3 An example of front loading the pin in an assembled connector . 8 Tabl
20、e 1 Pin specifications 5 Table 2 Test conditions 6 BS EN 61300-3-46:201161300-3-46 IEC:2011 5 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 3-46: Measurement Bore diameter for guide pin in MT ferrules 1 Scope The purpose of this part of IEC 613
21、00 is to provide a standard for the measurement of guide pin bore diameters in thermoplastic and thermoset MT ferrules specified in IEC 61754-5. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition ci
22、ted applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements, Visual examination. IEC 6175
23、4-5, Fibre optic connector interfaces - Part 5: Type MT connector family 3 General description 3.1 Pin specifications See Table 1 for pin specifications. Table 1 Pin specifications Material Tungsten Carbide Steel Pin Diameter ranges (mm) 0,69 895 to 0,69 905 0,69 905 to 0,69 915 0,69 915 to 0,69 925
24、 0,69 925 to 0,69 935 0,69 935 to 0,69 945 0,69 945 to 0,69 955 0,69 955 to 0,69 965 0,69 965 to 0,69 975 0,69 975 to 0,69 985 0,69 985 to 0,69 995 0,69 995 to 0,70 005 Cylindricity 100,0 nm or better Surface finish 0,2 m BS EN 61300-3-46:2011 6 61300-3-46 IEC:2011 3.2 Test conditions See Table 2 fo
25、r test conditions. Table 2 Test conditions Temperature (T) Relative Humidity (RH) Total Assembly Mass g 21,0 C to 25,0 C 50,0% RH 10,0 % 100,0 +/- 5,0 g 3.3 Apparatus The apparatus shall include the following elements: Traceable, calibrated gauge pins of tungsten carbide steel, 0,698 95 mm to 0,700
26、05 mm in 100 nm increments; Pin vice with rod and platform to hold calibrated mass elements, the mass of which is sufficient to make the entire assembly 100,0 g total. Fixturing should ensure that the assembly is free to hang vertically during testing. Both pins and test parts should be as clean as
27、possible to ensure an accurate measurement. 4 Procedure Parts should be preconditioned using the conditions in 3.2 for a minimum of 24 hours. Once conditioned, a calibrated gauge pin is pushed into the ferrule until it clears the ferrule end as shown in Figure 1. Start with a pin that should fit fre
28、ely in the part under test. Rear entry is recommended where possible to reduce the risk of ferrule end face damage. (For fully assembled product, front entry may be used as an alternative to disassembly as shown in Figure 3.) After the pin engages the full bore ID length, the pin vice is secured to
29、the calibrated gauge pin/ferrule vice assembly as shown in Figure 2. The mass is gradually released, pulling the pin through the bore. This procedure is repeated using increasingly larger pins until the 100,0 g 5,0 g mass cannot freely pull the pin out of the bore. Once this state is reached, the pr
30、evious pins diameter is recorded as the effective diameter of the guide pin bore. Repeat the above procedure for the opposite hole. BS EN 61300-3-46:201161300-3-46 IEC:2011 7 IEC 1208/11 Figure 1 Gauge pin through ferrule IEC 1209/11 Figure 2 An example of a complete measurement apparatus with ferru
31、le BS EN 61300-3-46:2011 8 61300-3-46 IEC:2011 IEC 1210/11 Figure 3 An example of front loading the pin in an assembled connector 5 Post test examination After the test is completed, visually examine the specimens in accordance with IEC 61300-3-1. Check for damage to the exit region of the guide pin
32、 bore breakage, chipping or scratching of the ferrule face 6 Details to be specified Test conditions Size range of pins used Final size of each bore _ BS EN 61300-3-46:2011This page deliberately left blankBSI is the independent national body responsible for preparing British Standardsand other stand
33、ards-related publications, information and services. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (
34、0)20 8996 9001Fax +44 (0)20 8996 Standards are updated by amendment or revision. Users of British Stan-dards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and serv-ices. We would be grateful if anyone findin
35、g an inaccuracy or ambiguity whileusing this British Standard would inform the Secretary of the technical com-mittee responsible, the identity of which can be found on the inside frontcover.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers Members an individual updating service called PLUS
36、 which ensuresthat subscribers automatically receive the latest editions of standards.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard copy versions of standards directly using acredit card from the BSI Shop on the website addition all orders for BSI,
37、 international and foreign standards publicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: In response to orders for international standards, it is BSI policy tosupply the BSI implementation of those that have been publishedas British Standards
38、, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, Europeanand international standards through its Knowledge Centre.Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005Email: Various BSI electronic information services are also available whichgive
39、 details on all its products and services. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048Email: BSI Subscribing Members are kept up to date with standardsdevelopments and receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact Membership Ad
40、-ministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via BritishStandards Online can be found at information about BSI is available on the BSI website at www.bsi- subsists in all BSI publications. BSI also holds the copyri
41、ght,in the UK, of the publications of the international standardization bodies. Ex-cept as permitted under the Copyright, Designs and Patents Act 1988 no ex-tract may be reproduced, stored in a retrieval system or transmitted in anyform or by any means electronic, photocopying, recording or otherwis
42、e without prior written permission from BSI. This does not preclude the freeuse, in the course of implementing the standard of necessary details such assymbols, and size, type or grade designations. If these details are to be usedfor any other purpose than implementation then the prior written permissionof BSI must be obtained. Details and advice can be obtained from the Copy-right & Licensing Manager.Tel: +44 (0)20 8996 7070Email: