EN 61347-2-9-2013 en Lamp controlgear - Part 2-9 Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps).pdf

上传人:amazingpat195 文档编号:720155 上传时间:2019-01-04 格式:PDF 页数:36 大小:1.21MB
下载 相关 举报
EN 61347-2-9-2013 en Lamp controlgear - Part 2-9 Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps).pdf_第1页
第1页 / 共36页
EN 61347-2-9-2013 en Lamp controlgear - Part 2-9 Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps).pdf_第2页
第2页 / 共36页
EN 61347-2-9-2013 en Lamp controlgear - Part 2-9 Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps).pdf_第3页
第3页 / 共36页
EN 61347-2-9-2013 en Lamp controlgear - Part 2-9 Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps).pdf_第4页
第4页 / 共36页
EN 61347-2-9-2013 en Lamp controlgear - Part 2-9 Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps).pdf_第5页
第5页 / 共36页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationLamp controlgearPart 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)BS EN 61347-2-9:2013National forewordThis Briti

2、sh Standard is the UK implementation of EN 61347-2-9:2013. It is identical to IEC 61347-2-9:2013. It supersedes BS EN 61347-2-9:2001+A2:2006, which will be withdrawn on 4 December 2015.The UK participation in its preparation was entrusted by Technical Committee CPL/34, Lamps and Related Equipment, t

3、o Subcommittee CPL/34/3, Auxiliaries for lamps.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Sta

4、ndards Institution 2013.Published by BSI Standards Limited 2013.ISBN 978 0 580 72014 7 ICS 29.140.99Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 20

5、13.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61347-2-9:2013EUROPEAN STANDARD EN 61347-2-9 NORME EUROPENNE EUROPISCHE NORM January 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches

6、 Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61347-2-9:2013 E ICS 29.140.99 Supersedes EN 61347-2-9:2001 + corr. Jul.2003 + corr.

7、 Dec.2010 + A1:2003 + A2:2006 English version Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) (IEC 61347-2-9:2012) Appareillages de lampes - Partie 2-9: Exigences particulires pour les appareillages lectromagntiqu

8、es pour lampes dcharge ( lexclusion des lampes fluorescentes) (CEI 61347-2-9:2012) Gerte fr Lampen - Teil 2-9: Besondere Anforderungen an elektromagnetische Betriebsgerte fr Entladungslampen (ausgenommen Leuchtstofflampen) (IEC 61347-2-9:2012) This European Standard was approved by CENELEC on 2012-1

9、2-04. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obt

10、ained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified

11、to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greec

12、e, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 61347-2-9:2013EN 61347-2-9:2013 Foreword The text of document 34C/1022/FDIS, future edit

13、ion 2 of IEC 61347-2-9, prepared by SC 34C, “Auxiliariesfor lamps“, of IEC TC 34, “Lamps and related equipment“ was submitted to the IEC-CENELEC parallelvote and approved by CENELEC as EN 61347-2-9:2013. The following dates are fixed: latest date by which the document has to be implemented at nation

14、al level bypublication of an identical national standard or by endorsement (dop) 2013-09-04 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2015-12-04 This document supersedes EN 61347-2-9:2001 + corr. Jul.2003 + corr. Dec.2010 + A1:2003 + A2:2006

15、. EN 61347-2-9:2013 includes the following significant technical changes with respect to EN 61347-2-9:2001: a) the addition of a new Clause 14; b) the word “ballast“ is changed to “electromagnetic controlgear“. This standard shall be used in conjunction with EN 61347-1. This Part 2-9 supplements or

16、modifies the corresponding clauses in EN 61347-1, so as to convert thatpublication into the European Standard: Particular requirements for electromagnetic controlgear fordischarge lamps (excluding fluorescent lamps). Where the requirements of any of the clauses of EN 61347-1 are referred to in this

17、standard by thephrase “The requirements of clause n of EN 61347-1 apply“, this phrase is interpreted as meaning that allrequirements of the clause in question of Part 1 apply, except any which are clearly inapplicable to thespecific type of lamp controlgear covered by this particular part of EN 6134

18、7-2. NOTE In this standard, the following print types are used: Requirements proper: in roman type. Test specifications: in italic type. Explanatory matter: in smaller roman type. Attention is drawn to the possibility that some of the elements of this document may be the subject ofpatent rights. CEN

19、ELEC and/or CEN shall not be held responsible for identifying any or all such patentrights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designedfor Use within Certain Voltage Limits (LVD - 2006/95/EC). BS EN 61347-2-9:2013EN 61347-2-9:2013 Endorsemen

20、t notice The text of the International Standard IEC 61347-2-9:2012 was approved by CENELEC as a EuropeanStandard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60923 NOTE Harmonized as EN 60923. IEC 61167 NOT

21、E Harmonized as EN 61167. IEC 61347-2-8 NOTE Harmonized as EN 61347-2-8. BS EN 61347-2-9:2013EN 61347-2-9:2013 Annex ZA (normative) Normative references to international publicationswith their corresponding European publications The following documents, in whole or in part, are normatively reference

22、d in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modificatio

23、ns, indicated by (mod), the relevant EN/HDapplies. Year Publication EN/HD Title Year IEC 60188 - High-pressure mercury vapour lamps - Performance specifications EN 60188 - IEC 60192 - Low pressure sodium vapour lamps - Performance specifications EN 60192 - IEC 60598-1 - Luminaires - Part 1: General

24、requirements and tests EN 60598-1 - IEC 60662 - High pressure sodium vapour lamps - Performance specifications EN 60662 - IEC 61347-1 (mod)+ A1 20072010 Lamp controlgear - Part 1: General and safety requirements EN 61347-1 + A1 20082011 IEC 61347-2-1 - Lamp controlgear - Part 2-1: Particular require

25、ments for starting devices (other than glow starters) EN 61347-2-1 - IEC 62035 (mod) - Discharge lamps (excluding fluorescentlamps) - Safety specifications EN 62035 - BS EN 61347-2-9:201361347-2-9 IEC:2012 CONTENTS INTRODUCTION . 6 1 Scope . . 7 2 Normative references . 7 3 Terms and definitions . 7

26、 4 General requirements . 8 4.1 General . 8 4.2 Capacitors and other components 8 4.3 Thermally protected electromagnetic controlgear . 8 5 General notes on tests . 8 6 Classification 9 7 Marking . 9 7.1 General . 9 7.2 Mandatory markings . 9 7.3 Information to be provided, if applicable 9 7.4 Other

27、 information 9 8 Protection against accidental contact with live parts . 10 9 Terminals . 10 10 Provisions for earthing 10 11 Moisture resistance and insulation 10 12 Electric strength 10 13 Thermal endurance test for windings . 10 14 Electromagnetic controlgear heating . . 10 14.1 General . . 10 14

28、.2 Test requirements . 10 14.3 Normal operating condition 11 14.4 Abnormal operating condition . 11 15 High-voltage impulse testing 14 15.1 General . . 14 15.2 Test for electromagnetic controlgear operating with lamp with external starting devices . 14 15.3 Test for electromagnetic controlgear opera

29、ting with lamps with internal starting devices . 14 16 Fault conditions . 16 17 Construction . 16 18 Creepage distances and clearances . . 16 19 Screws, current-carrying parts and connections . 16 20 Resistance to heat, fire and tracking . . 16 21 Resistance to corrosion 16 22 No-load output voltage

30、 . 16 Annex A (normative) Test to establish whether a conductive part is a live part which may cause an electric shock . 17 Annex B (normative) Particular requirements for thermally protected lamp electromagnetic controlgear 18 BS EN 61347-2-9:201361347-2-9 IEC:2012 Annex C (normative) Particular re

31、quirements for electronic lamp controlgear with means of protection against overheating . . 19 Annex D (normative) Requirements for carrying out the heating tests of thermally protected lamp electromagnetic controlgear . 20 Annex E (normative) Use of constant S other than 4 500 in twtests . 21 Annex

32、 F (normative) Draught-proof enclosure 22 Annex G (normative) Explanation of the derivation of the values of pulse voltages . 23 Annex H (normative) Tests. 24 Annex I (normative) Method for selection of varistors 25 Annex J (informative) Explanation of electromagnetic controlgear temperatures . 26 A

33、nnex K (normative) Additional requirements for built-in electromagnetic controlgear with double or reinforced insulation . 29 Bibliography . 30 Figure 1 Test circuit for electromagnetic controlgear for lamps with integral starting devices . . 15 Figure J.1 Test hood for electromagnetic controlgear h

34、eating test 28 Figure J.2 Test corner for electromagnetic controlgear heating . . 28 Table 1 Test voltages for electromagnetic controlgear generating pulse voltages . 10 Table 2 Maximum temperatures . 12 Table 3 Limiting temperatures of windings under abnormal operating conditions and at 110 % of ra

35、ted voltage for electromagnetic controlgear subjected to endurance test duration of 30 days 13 Table 4 Limiting temperatures of windings under abnormal operating conditions and at 110 % of rated voltage for electromagnetic controlgear marked D6 which are subjected to an endurance test duration of 60

36、 days 13 BS EN 61347-2-9:2013 6 61347-2-9 IEC:2012 INTRODUCTION This second edition of IEC 61347-2-9 is published in conjunction with IEC 61347-1. The formatting into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a

37、need for them is recognized. This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which the tests are to be performed; they also include additional requirements, as necessar

38、y. All parts which make up IEC 61347-2 are self-contained and, therefore, do not include references to each other. BS EN 61347-2-9:201361347-2-9 IEC:2012 7 LAMP CONTROLGEAR Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) 1 Scope Thi

39、s part of the IEC 61347 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic control

40、gear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This standard applies to complete electromagnetic controlgear and to their component parts such as

41、 reactors, transformers and capacitors. Particular requirements for thermally protected electromagnetic controlgear are given in Annex B. For certain types of discharge lamps, an ignitor is required. NOTE Electromagnetic controlgear for fluorescent lamps are covered by IEC 61347-2-8. Performance req

42、uirements are the subject of IEC 60923. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the

43、referenced document (including any amendments) applies. IEC 60188, High-pressure mercury vapour lamps Performance specifications IEC 60192, Low-pressure sodium vapour lamps Performance specifications IEC 60598-1, Luminaires Part 1: General requirements and tests IEC 60662, High-pressure sodium vapou

44、r lamps Performance specifications IEC 61347-1:2007, Lamp controlgear Part 1: General and safety requirements Amendment 1:2010 IEC 61347-2-1, Lamp controlgear Part 2-1: Particular requirements for starting devices (other than glow starters) IEC 62035, Discharge lamps (excluding fluorescent lamps) Sa

45、fety specifications 3 Terms and definitions For the purpose of this document, the terms and definitions given in IEC 61347-1:2007, together with the following apply: BS EN 61347-2-9:2013 8 61347-2-9 IEC:2012 3.1 rated temperature rise of an electromagnetic controlgear winding t temperature rise assi

46、gned by the manufacturer under the conditions specified in this standard Note 1 to entry: The specifications for the supply and mounting conditions of the electromagnetic controlgear are given in Annex H. 3.2 high-voltage impulse intentionally applied periodic transient voltage which rises rapidly t

47、o a peak value and then falls, usually less rapidly, to zero Note 1 to entry: The term “impulse“ is to be distinguished from the term “surge“, which refers to transients occurring in electrical equipment or networks in service. Note 2 to entry: Such an impulse is, in general, well represented by the

48、 sum of two exponentials. 4 General requirements 4.1 General The requirements of Clause 4 of IEC 61347-1:2007 apply, together with the following additional requirements: 4.2 Capacitors and other components Capacitors and other components incorporated in electromagnetic controlgear shall comply with

49、the requirements of the appropriate IEC standard. 4.3 Thermally protected electromagnetic controlgear Thermally protected electromagnetic controlgear shall comply with the requirements of Annex B. 5 General notes on tests The requirements of Clause 5 of IEC 61347-1:2007 apply, together with the following additional requirements: The type test is carried out on one sample consisting of eight electromagnetic controlgear submitted for the purpose of the type test. Seven electromagnetic contr