1、BSI Standards PublicationElectricity metering data exchange TheDLMS/COSEM suitePart 8-3: Communication profile for PLC S-FSK neighbourhood networksBS EN 62056-8-3:2013National forewordThis British Standard is the UK implementation of EN 62056-8-3:2013. It isidentical to IEC 62056-8-3:2013.The UK par
2、ticipation in its preparation was entrusted to TechnicalCommittee PEL/13, Electricity Meters.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible
3、for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 75067 0ICS 17.220.01; 35.110; 91.140.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of
4、theStandards Policy and Strategy Committee on 30 September 2013.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 62056-8-3:2013EUROPEAN STANDARD EN 62056-8-3 NORME EUROPENNE EUROPISCHE NORM August 2013 CENELEC European Committee for Electrotechnical Standardizati
5、on Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62056-8-3:
6、2013 E ICS 17.220; 35.110; 91.140.50 English version Electricity metering data exchange - The DLMS/COSEM suite - Part 8-3: Communication profile for PLC S-FSK neighbourhood networks (IEC 62056-8-3:2013) Echange des donnes de comptage de llectricit - La suite DLMS/COSEM - Partie 8-3: Profil de commun
7、ication pour rseaux de voisinage CPL S-FSK (CEI 62056-8-3:2013) Datenkommunikation der elektrischen Energiemessung - DLMS/COSEM - Teil 8-3: PLC S-FSK Spezifikation fr Areal-Netze (IEC 62056-8-3:2013) This European Standard was approved by CENELEC on 2013-06-20. CENELEC members are bound to comply wi
8、th the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Mana
9、gement Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
10、 same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
11、 Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 62056-8-3:2013EN 62056-8-3:2013 - 2 - Foreword The text of document 13/1526/FDIS, future edition 1 of IEC 62056-8-3, prepared by IEC
12、/TC 13 “Electrical energy measurement, tariff- and load control“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62056-8-3:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical nation
13、al standard or by endorsement (dop) 2014-03-20 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-06-20 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shal
14、l not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 62056-8-3:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added
15、 for the standard indicated: IEC 61334-4-512:2001 NOTE Harmonized as EN 61334-4-512:2002 (not modified). BS EN 62056-8-3:2013- 3 - EN 62056-8-3:2013 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whol
16、e or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication
17、has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050 Series International Electrotechnical Vocabulary (IEV) - - IEC 61334-4-1 1996 Distribution automation using distribution line carrier systems - Part 4: Data communic
18、ation protocols - Section 1: Reference model of the communication system EN 61334-4-1 1996 IEC 61334-4-32 1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC) EN 61334-4-32 1996 IEC 6133
19、4-4-511 2000 Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol EN 61334-4-511 2000 IEC 61334-5-1 2001 Distribution automation using distribution line carrier systems - Part 5-1: Lower layer profiles - The
20、spread frequency shift keying (S-FSK) profile EN 61334-5-1 2001 IEC/TR 62051 1999 Electricity metering - Glossary of terms - - IEC/TR 62051-1 + corr. June 2004 2005 Electricity metering - Data exchange for meter reading, tariff and load control - Glossary of terms - Part 1: Terms related to data exc
21、hange with metering equipment using DLMS/COSEM - - IEC 62056-5-3 2013 Electricity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer EN 62056-5-3 2013 IEC 62056-6-2 2013 Electricity metering data exchange - The DLMS/COSEM suite - Part 6-2: COSEM interface classes
22、EN 62056-6-2 2013 IEC 62056-46 + A1 2002 2006 Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol EN 62056-46 + A1 2002 2007 ISO/IEC 8802-2 + corr. October 1998 2000 Information technology - Telecommunications and information
23、 exchange between systems - Local and metropolitan area networks - Specific requirements - Part 2: Logical link control - - BS EN 62056-8-3:2013 2 62056-8-3 IEC:2013 CONTENTS 1 Scope . 6 2 Normative references . 6 3 Terms, definitions and abbreviations 7 Terms and definitions 7 3.1Abbreviations 8 3.
24、24 Targeted communication environments . 9 5 Reference model 11 6 The physical layer (PhL) . 11 7 The data link layer 12 General . 12 7.1The MAC sublayer . 12 7.2The connectionless LLC sublayer 12 7.3The HDLC based LLC sublayer . 13 7.4Co-existence of the connectionless and the HDLC based LLC sublay
25、ers . 13 7.58 The application layer (AL) . 14 9 The application process (AP) 14 10 The Configuration Initiation Application Service Element (CIASE) 14 Overview . 14 10.1The Discover service . 14 10.2The Register service . 15 10.3The Ping Service . 15 10.4The RepeaterCall service 17 10.5The ClearAlar
26、m service . 19 10.6The Intelligent Search Initiator process . 21 10.7General . 21 10.7.1Operation 21 10.7.2The Discovery and Registration process 24 10.8Abstract and transfer syntax 28 10.911 Addressing . 28 General . 28 11.1IEC 61334-5-1 MAC addresses . 28 11.2Reserved special LLC addresses 28 11.3
27、General . 28 11.3.1Reserved addresses for the IEC 61334-4-32 LLC sublayer 29 11.3.2Reserved addresses for the HDLC based LLC sublayer . 29 11.3.3Source and destination APs and addresses of CI-PDUs 30 11.3.412 Specific considerations / constraints for the IEC 61334-4-32 LLC sublayer based profile . 3
28、1 Establishing application associations . 31 12.1Application association types, confirmed and unconfirmed xDLMS services 33 12.2xDLMS client/server type services . 33 12.3Releasing application associations 33 12.4Service parameters of the COSEM-OPEN / -RELEASE / -ABORT services 34 12.5The EventNotif
29、ication service and the TriggerEventNotificationSending 12.6service 34 BS EN 62056-8-3:201362056-8-3 IEC:2013 3 Transporting long messages 35 12.7Broadcasting . 35 12.813 Specific considerations / constraints for the HDLC LLC sublayer based profile . 35 Establishing Application Associations 35 13.1A
30、pplication association types, confirmed and unconfirmed xDLMS services 36 13.2xDLMS client/server type services . 37 13.3Correspondence between AAs and data link layer connections, releasing 13.4AAs . 37 Service parameters of the COSEM-OPEN/ -RELEASE/ -ABORT services 37 13.5The EventNotification ser
31、vice and protocol 37 13.6Transporting long messages 37 13.7Broadcasting . 37 13.814 Abstract syntax of CIASE APDUs . 37 Annex A (informative) S-FSK PLC encoding examples . 39 Bibliography 51 Index 52 Figure 1 Communication architecture . 10 Figure 2 The DLMS/COSEM S-FSK PLC communication profile . 1
32、1 Figure 3 Co-existence of the connectionless and the HDLC based LLC sublayers 13 Figure 4 Intelligent Search Initiator process flow chart . 22 Figure 5 The Discovery and Registration process 25 Figure 6 MSC for the discovery and registration process 32 Figure 7 MSC for successful confirmed AA estab
33、lishment 32 Figure 8 MSC for releasing an Application Association 34 Figure 9 MSC for an EventNotification service . 35 Figure 10 MSC for the Discovery and Registration process 36 Figure 11 MSC for successful confirmed AA establishment and the GET service . 36 Table 1 Service parameters of the Disco
34、ver service primitives . 15 Table 2 Service parameters of the Register service primitives . 15 Table 3 Service parameters of the PING service primitives 16 Table 4 Service parameters of the RepeaterCall service primitives 17 Table 5 Service parameters of the ClearAlarm service primitives . 20 Table
35、6 MAC addresses . 28 Table 7 Reserved IEC 61334-4-32 LLC addresses on the client side . 29 Table 8 Reserved IEC 61334-4-32 LLC addresses on the server side 29 Table 9 Reserved HDLC based LLC addresses on the client side 29 Table 10 Reserved HDLC based LLC addresses on the server side . 29 Table 11 S
36、ource and Destination APs and addresses of CI-PDUs 31 Table 12 Application associations and data exchange in the S-FSK PLC profile using the connectionless LLC sublayer 33 BS EN 62056-8-3:2013 6 62056-8-3 IEC:2013 ELECTRICITY METERING DATA EXCHANGE THE DLMS/COSEM SUITE Part 8-3: Communication profil
37、e for PLC S-FSK neighbourhood networks 1 Scope This part of IEC 62056 specifies the DLMS/COSEM PLC S-SFK communication profile for neighbourhood networks. It uses standards established by IEC TC 57 in the IEC 61334 series, Distribution automation using distribution line carrier systems and it specif
38、ies extensions to some of those standards. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of t
39、he referenced document (including any amendments) applies. IEC 60050 (all parts), International Electrotechnical Vocabulary (available at http:/www.electropedia.org) IEC 61334-4-1:1996, Distribution automation using distribution line carrier systems Part 4: Data communication protocols Section 1: Re
40、ference model of the communication system IEC 61334-4-32:1996, Distribution automation using distribution line carrier systems Part 4: Data communication protocols Section 32: Data link layer Logical link control (LLC) IEC 61334-4-511:2000, Distribution automation using distribution line carrier sys
41、tems Part 4-511: Data communication protocols Systems management CIASE protocol IEC 61334-5-1:2001, Distribution automation using distribution line carrier systems Part 5-1: Lower layer profiles The spread frequency shift keying (S-FSK) profile IEC/TR 62051:1999, Electricity metering Glossary of ter
42、ms IEC/TR 62051-1:2004, Electricity metering Data exchange for meter reading, tariff and load control Glossary of terms Part 1: Terms related to data exchange with metering equipment using DLMS/COSEM IEC 62056-46:2002, Electricity metering Data exchange for meter reading, tariff and load control Par
43、t 46: Data link layer using HDLC protocol Amendment 1:2006 IEC 62056-5-3:, Electricity metering data exchange The DLMS/COSEM suite Part 5-3: DLMS/COSEM application layer2_ 2To be published simultaneously with this part of IEC 62056. BS EN 62056-8-3:201362056-8-3 IEC:2013 7 IEC 62056-6-2:, Electricit
44、y metering data exchange The DLMS/COSEM suite Part 6-2: COSEM interface classes3ISO/IEC 8802-2:1998, Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 2: Logical link control NOTE See also the Bibliograp
45、hy. 3 Terms, definitions and abbreviations For the purposes of this document, the terms and definitions given in IEC 60050-300, IEC/TR 62051 and IEC/TR 62051-1 and the following apply. Where there is a difference between the definitions in the glossary and those contained in product standards produc
46、ed by TC 13, then the latter shall take precedence in applications of the relevant standard. Terms and definitions 3.13.1.1initiator user-element of a client System Management Application Entity (SMAE). It uses the CIASE and xDLMS ASE and it is identified by its system title SOURCE: IEC 61334-4-511:
47、2000, 3.8.1, modified 3.1.2active initiator initiator, which issues or has last issued a CIASE Register request when the server is in the unconfigured state SOURCE: IEC 61334-4-511:2000, 3.9.1 3.1.3new system server system, which is in the unconfigured state: its MAC address equals “NEW-address“ SOU
48、RCE: IEC 61334-4-511:2000, 3.9.3 3.1.4new system title system-title of a new system Note 1 to entry: This is the system title of a system, which is in the new state. SOURCE: IEC 61334-4-511:2000, 3.9.4, modified 3.1.5registered system server system, which has an individual, valid MAC address Note 1
49、to entry: Therefore, this MAC address is different from “NEW Address“, see IEC 61334-5-1: Medium Access Control. SOURCE: IEC 61334-4-511:2000, 3.9.5, modified _ 3To be published simultaneously with this part of IEC 62056. BS EN 62056-8-3:2013 8 62056-8-3 IEC:2013 3.1.6reporting system server system, which issues a DiscoverReport SOURCE: IEC 61334-4-511:2000, 3.9.6, modified 3.1.7sub-timeslot the time n