1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationLightning Protection SystemComponents (LPSC)Part 7: Requirements for earthing enhancing compoundsBS EN 62561-7:2012National forewordThis British Standard is the UK implementation
2、 of EN 62561-7:2012. It is derived from IEC 62561-7:2011. It supersedes BS EN 50164-7:2008 which will be withdrawn on 2 January 2015.The UK participation in its preparation was entrusted to Technical Commit-tee GEL/81, Protection against lightning.A list of organizations represented on this committe
3、e can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012 ISBN 978 0 580 66746 6 ICS 29.020; 9
4、1.120.40Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Stand-ards Policy and Strategy Committee on 30 April 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62561-
5、7:2012EUROPEAN STANDARD EN 62561-7 NORME EUROPENNE EUROPISCHE NORM April 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 C
6、ENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62561-7:2012 E ICS 29.020; 91.120.40 Supersedes EN 50164-7:2008English version Lightning Protection System Components (LPSC) - Part 7: Requirements for earthing enhancing compounds (I
7、EC 62561-7:2011, modified) Composants des systmes de protection contre la foudre (CSPF) - Partie 7: Exigences pour les enrichisseurs de terre (CEI 62561-7:2011, modifie) Blitzschutzsystembauteile (LPSC) - Teil 7: Anforderungen an Mittel zur Verbesserung der Erdung (IEC 62561-7:2011, modifiziert) Thi
8、s European Standard was approved by CENELEC on 2012-01-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical ref
9、erences concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of
10、 a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France,
11、Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 62561-7:2012EN 62561-7:2012 - 2 - Foreword The text of document 81/413/FDI
12、S, future edition 1 of IEC 62561-7, prepared by IEC/TC 81 “Lightning protection“, was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62561-7:2012. A draft amendment, which covers common modifications to IEC 62561-7 (81/413/FDIS), was prepared by CLC/TC 81X,“Lightning protec
13、tion“ and approved by CENELEC. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-01-02 latest date by which the national standards conflicting with the document have t
14、o be withdrawn (dow) 2015-01-02 This document supersedes EN 50164-7:2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement
15、notice The text of the International Standard IEC 62561-7:2011 was approved by CENELEC as a European Standard with common modifications. COMMON MODIFICATIONS Introduction Replace IEC 62561 by EN 62561. Replace IEC 62305 by EN 62305. 1 Scope Replace IEC 62561 by EN 62561. Bibliography Replace IEC 623
16、05 by EN 62305. Replace IEC 62561-2 by EN 62561-2 1). 1)At draft stage. BS EN 62561-7:2012- 3 - EN 62561-7:2012 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referen
17、ced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modificat
18、ions, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year - - Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle siz
19、e below 4 mm (without or with size reduction) EN 12457-2 - - - Characterization of waste - Analysis of eluates - Determination of pH, As, Ba, Cd, Cl-, Co, Cr, Cr Vl, Cu, Mo, Ni, NO2-, Pb, total S, SO42-, V and Zn EN 12506 - ISO 4689-3 - Iron ores - Determination of sulfur content - Part 3: Combustio
20、n/infrared method - - ISO 14869-1 - Soil quality - Dissolution for the determination of total element content - Part 1: Dissolution with hydrofluoric and perchloric acids - - ASTM G57-06 - Standard Test Method for Field Measurement of Soil Resistivity Using the Wenner Four-Electrode Method - - ASTM
21、G59-97 - Standard Test Method for Conducting Potentiodynamic Polarization Resistance Measurements - - ASTM G102-89 - Standard Practice for Calculation of Corrosion Rates and Related Information from Electrochemical Measurements - - BS EN 62561-7:2012 2 62561-7 IEC:2011 CONTENTS INTRODUCTION . 6 1 Sc
22、ope . 7 2 Normative references . 7 3 Terms and definitions . 7 4 Requirements . 8 4.1 General . 8 4.2 Documentation 8 4.3 Material . 8 4.4 Marking . 8 5 Tests 8 5.1 General . 8 5.2 Leaching test . 9 5.2.1 General . 9 5.2.2 Determination of leachable ions . 9 5.2.3 Passing criteria 9 5.3 Sulphur dete
23、rmination . 9 5.3.1 General . 9 5.3.2 Passing criteria 9 5.4 Determination of resistivity 9 5.4.1 General . 9 5.4.2 Testing apparatus 10 5.4.3 Test procedure 11 5.4.4 Passing criteria 12 5.5 Corrosion tests 12 5.5.1 General . 12 5.5.2 Test apparatus . 12 5.5.3 Test preparation 12 5.5.4 Test procedur
24、e . 12 5.5.5 Passing criteria 12 5.6 Marking and indications . 12 6 Structure and content of the test report 13 6.1 General . 13 6.2 Report identification 13 6.2.1 Title or subject of the report . 13 6.2.2 Name, address and telephone number of the test laboratory . 13 6.2.3 Name, address and telepho
25、ne number of the sub test laboratory where the test was carried out if different from company which has been assigned to perform the test 13 6.2.4 Unique identification number (or serial number) of the test report 13 6.2.5 Name and address of the vendor . 13 6.2.6 Report shall be paginated and the t
26、otal number of pages indicated . 13 6.2.7 Date of issue of report . 13 6.2.8 Date(s) of performance of test(s) . 13 BS EN 62561-7:201262561-7 IEC:2011 3 6.2.9 Signature and title, or an equivalent identification of the person(s) authorized to sign for the testing laboratory for the content of the re
27、port 13 6.3 Signature and title of person(s) conducting the test . 14 6.4 Specimen description 14 6.4.1 Sample description 14 6.4.2 Detailed description and unambiguous identification of the test sample and/or test assembly . 14 6.4.3 Characterization and condition of the test sample and/or test ass
28、embly . 14 6.4.4 Sampling procedure, where relevant 14 6.4.5 Date of receipt of test items . 14 6.4.6 Photographs, drawings or any other visual documentation, if available 14 6.4.7 Standards and references 14 6.4.8 Identification of the test standard used and the date of issue of the standard 14 6.4
29、.9 Other relevant documentation with the documentation date . 14 6.5 Test procedure 14 6.5.1 Description of the test procedure . 14 6.5.2 Justification for any deviations from, additions to or exclusions from the referenced standard. 14 6.5.3 Any other information relevant to a specific test such as
30、 environmental conditions . 14 6.5.4 Configuration of testing assembly 14 6.5.5 Location of the arrangement in the testing area and measuring techniques . 14 6.6 Testing equipment, description 14 6.7 Measuring instruments description 14 6.8 Results and parameters recorded 14 6.8.1 The measured, obse
31、rved or derived results shall be clearly identified, at least for . 14 6.8.2 Statement pass/fail 15 Bibliography 16 Figure 1 Configuration of fourelectrode soil box . 11 BS EN 62561-7:2012 6 62561-7 IEC:2011 INTRODUCTION This Part 7 of IEC 62561 deals with the requirements and tests for earthing enh
32、ancing compounds as being a lightning protection system components (LPSC) designed and implemented according to the IEC 62305 series of standards. BS EN 62561-7:201262561-7 IEC:2011 7 LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) Part 7: Requirements for earthing enhancing compounds 1 Scope This Par
33、t 7 of IEC 62561 specifies the requirements and tests for earthing enhancing compounds producing low resistance of an earth termination system. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application.
34、For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 4689-3, Iron ores Determination of sulfur content Part 3: Combustion/infrared method ISO 14869-1, Soil quality Dissolution for the deter
35、mination of total element content Part 1: Dissolution with hydrofluoric and perchloric acids EN 12457-2, Characterization of waste Leaching Compliance test for leaching of granular waste materials and sludges Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with parti
36、cle size below 4 mm (without or with size reduction) EN 12506, Characterization of waste Analysis of eluates Determination of pH, As, Ba, Cd, Cl-, Co, Cr Vl, Cu, Mo, Ni, NO2, SO42-, V and Zn ASTM G57-06. Standard Test Method for Field Measurement of Soil Resistivity, Using the Wenner, Four-Electrode
37、 Method ASTM G59-97, Standard Test Method for Conducting Potentiodynamic Polarization Resistance Measurements ASTM G102-89, Standard Practice for Calculation of Corrosion Rates and Related Information from Electrochemical Measurements 3 Terms and definitions For the purposes of this document, the fo
38、llowing terms and definitions apply. 3.1 earthing enhancing compound conductive compound producing low resistance of an earth termination system 3.2 manufacturers instructions suppliers instructions written instructions provided by the manufacturer or the supplier in his documentation (see 4.2) BS E
39、N 62561-7:2012 8 62561-7 IEC:2011 3.3 leaching test test during which the earthing enhancing compound is put into contact with a leachant and some constituents of the material are extracted 4 Requirements 4.1 General Earthing enhancing compounds shall be so designed and constructed that in normal us
40、e their performance is reliable and without danger to persons and the surrounding. The choice of a material depends on its ability to match the particular application requirements. 4.2 Documentation The manufacturer or supplier of the earthing enhancing compounds shall provide adequate information i
41、n his literature to ensure that the installer can select and install the materials in a suitable and safe manner. Compliance is checked by inspection. NOTE The manufacturer in his literature should provide information regarding the maintenance followed by the user over time in order for the characte
42、ristics of the earthing enhancing compound to remain stable. 4.3 Material The material of the earthing enhancing compound shall be chemically inert to subsoil. It shall not pollute the environment. It shall provide a stable environment in terms of physical and chemical properties and exhibit low res
43、istivity. The earthing enhancing compound shall not be corrosive to the earth electrodes being used. Compliance is checked by the tests specified in 5.2, 5.3, 5.4 and 5.5. 4.4 Marking All products complying with this standard shall be marked at least with the following: a) manufacturers or responsib
44、le vendors name or trade mark; b) identifying symbol; c) resistivity. The marking should be given on the packing unit. Compliance is checked in accordance with 5.6. 5 Tests 5.1 General The tests in accordance with this standard are type tests. Unless otherwise specified, tests are carried out with t
45、he specimens prepared as in normal use according to the manufacturers or suppliers instructions. All tests are carried out on new specimens. BS EN 62561-7:201262561-7 IEC:2011 9 NOTE Unless otherwise specified, three samples are subjected to each individual test and the requirements are satisfied if
46、 all the criteria are met. The applicant, when submitting the material to be tested, may also submit an additional quantity which may be necessary should one test fail. The testing station will then, without further request, repeat the test and will reject only if a further failure occurs. If the ad
47、ditional sample is not submitted at the same time, the failure of one test will entail rejection. 5.2 Leaching test 5.2.1 General The leaching test shall be performed according to EN 12457-2: Fe (iron); Cu (copper); Zn (zinc); Ni (nickel); Cd (cadmium); Co (cobalt); Pb (lead). 5.2.2 Determination of
48、 leachable ions Determination of the concentrations of constituents of interest shall be performed according to EN 12506. 5.2.3 Passing criteria The criteria are given by national or international regulations. 5.3 Sulphur determination 5.3.1 General A test for the determination of sulphur shall be p
49、erformed according to ISO 4689-3 or ISO 14869-1 and the adapted analyses instrumentation (ICP-OES, ICP-AES or other ICP methods). 5.3.2 Passing criteria The material is deemed to have passed the test if all measured values are less than 2 %. The recorded value resulting from this test shall be indicated within the product documentation. 5.4 Determination of resistivity 5.4.1 General The fourelectrode method is used to measure the resistivity of earthing enhancing compounds as descr