EN ISO 6710-2017 en Single-use containers for human venous blood specimen collection.pdf

上传人:周芸 文档编号:723040 上传时间:2019-01-04 格式:PDF 页数:28 大小:1.67MB
下载 相关 举报
EN ISO 6710-2017 en Single-use containers for human venous blood specimen collection.pdf_第1页
第1页 / 共28页
EN ISO 6710-2017 en Single-use containers for human venous blood specimen collection.pdf_第2页
第2页 / 共28页
EN ISO 6710-2017 en Single-use containers for human venous blood specimen collection.pdf_第3页
第3页 / 共28页
EN ISO 6710-2017 en Single-use containers for human venous blood specimen collection.pdf_第4页
第4页 / 共28页
EN ISO 6710-2017 en Single-use containers for human venous blood specimen collection.pdf_第5页
第5页 / 共28页
点击查看更多>>
资源描述

1、Single-use containers for human venous blood specimen collection (ISO 6710:2017)BS EN ISO 6710:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard is the UK implementation of EN ISO 6710:2017. It is identical to ISO 6710:2017. I

2、t supersedes BS EN 14820:2004, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee CH/212, IVDs.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary

3、 provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 2017ISBN 978 0 580 95690 4ICS 11.100.30; 11.040.20Compliance with a British Standard cannot confer immunity from legal obligations.This British Stan

4、dard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2017.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN ISO 6710:2017EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 6710September 2017ICS 11.040.20 Supersedes

5、 EN 14820:2004EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGCEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN Ref. No. EN ISO 6710:2017: EAll rights of exploitation in any form and by any means reserved worldwide for CEN nat

6、ional MembersSingle-use containers for human venous blood specimen collection (ISO 6710:2017)Rcipients non rutilisables pour prlvements de sang veineux humain (ISO 6710:2017)Gefe zur einmaligen Verwendung fr die vense Blutentnahme (ISO 6710:2017)This European Standard was approved by CEN on 23 Augus

7、t 2017.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtain

8、ed on application to the CEN-CENELEC Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-C

9、ENELEC Management Centre has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, It

10、aly, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.English VersionEN ISO 6710:2017 (E)European forewordThis document (EN ISO 6710:2017) has been prepared by Technical Committee I

11、SO/TC 76 “Transfusion, infusion and injection, and blood processing equipment for medical and pharmaceutical use” in collaboration with Technical Committee CEN/TC 140 “In vitro diagnostic medical devices” the secretariat of which is held by DIN.This European Standard shall be given the status of a n

12、ational standard, either by publication of an identical text or by endorsement, at the latest by March 218, and conflicting national standards shall be withdrawn at the latest by September 2020.Attention is drawn to the possibility that some of the elements of this document may be the subject of pat

13、ent rights. CEN shall not be held responsible for identifying any or all such patent rights.This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s).For relationship with EU

14、 Directive(s), see informative Annex ZA, which is an integral part of this document.This document supersedes EN 14820:2004, of which the following has been changed: Clause “Introduction“ has been updated; Clause “Scope“ has been updated and phrased clearer. Blood culture bottles have been excluded f

15、rom this standard, as it does not address the special needs for this kind of testing; Clause “Normative references“ has been updated; Clause Terms and definitions“ has been updated and extended; Clause “Materials“ has been updated; Clause “Nominal liquid capacity“ has been shortened and renamed to “

16、Draw volume“; Clause “Graduation and fill lines“ has been deleted; Clause “Design“ has been updated; Clause “Construction“ has been updated and shortened; Clause “Sterility and special microbiological states“ has been technically revised; Clause “Additives“ has been updated and shortened; Clause “In

17、formation supplied by the manufacturer“ has been updated to meet current general requirements (except local requirements), and renamed to “Marking and labelling“; Clause “Receptacle and additive identification“ has been updated and renamed to “Container identification“. Table “Letter codes identifyi

18、ng the more common additives for blood specimen receptacles“ within this clause has been renamed to “Letter codes for identifying additives and accessories“ and extended by additional entries for additives; Tests in Normative Annexes A to D have been updated in alignment with the requirements in the

19、 body part of the standard. Annex A “Test for nominal liquid capacity and graduation marks, for non-evacuated blood specimen receptacles“ was renamed to “Draw volume test for non-evacuated containers“. Annex B “Test for draw volume for evacuated receptacles“ was renamed to “Draw volume test for evac

20、uated containers“ and a figure was added for better explanation. Annex C “Test for leakage from the closure of a receptacle“ was renamed to “Test for leakage of container“. Annex D “Test for the robustness of a receptacle that is intended for centrifugations“ was renamed to “test for robustness of t

21、he container“;2BS EN ISO 6710:2017EN ISO 6710:2017 (E) Normative Annex E “Concentrations of additives and volume of liquid additives“ has been added; Informative Annex F “Recommended colour codes for identifying additives and accessories“ has been added; The Bibliography has been updated.The followi

22、ng referenced documents are indispensable for the application of this document. For undated references, the latest edition of the referenced document (including any amendments) applies. For dated references, only the edition cited applies. However, for any use of this standard within the meaning of

23、Annex ZA, the user should always check that any referenced document has not been superseded and that its relevant contents can still be considered the generally acknowledged state-of-art.When an IEC or ISO standard is referred to in the ISO standard text, this shall be understood as a normative refe

24、rence to the corresponding EN standard, if available, and otherwise to the dated version of the ISO or IEC standard, as listed below.NOTE The way in which these referenced documents are cited in normative requirements determines the extent (in whole or in part) to which they apply.Table Correlations

25、 between normative references and dated EN and ISO standardsNormative references as listed in Clause 2 of the ISO standardEquivalent dated standardEN ISO or IECISO 15223-1 EN ISO 15223-1:2016 ISO 15223-1:2016According to the CEN-CENELEC Internal Regulations, the national standards organizations of t

26、he following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Nether

27、lands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.3BS EN ISO 6710:2017ISO 6710:2017(E)Foreword vIntroduction vii1 Scope . 12 Normative references 13 Terms and definitions . 14 Materials . 25 Draw volume . 36 Design 37 Cons

28、truction 38 Sterility and special microbiological states . 39 Additives 410 Marking and labelling . 411 Container identification 5Annex A (normative) Draw volume test for non-evacuated containers . 6Annex B (normative) Draw volume test for evacuated containers . 7Annex C (normative) Test for leakage

29、 of container. 9Annex D (normative) Test for robustness of the container .11Annex E (normative) Concentrations of additives and volume of liquid additives .12Annex F (informative) Recommended colour codes for identifying additives and accessories 14Bibliography .15iv ISO 2017 All rights reservedCont

30、ents PageBS EN ISO 6710:2017ISO 6710:2017(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member

31、 body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Elect

32、rotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of

33、 ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held

34、responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents).Any trade name used in this document is information g

35、iven for the convenience of users and does not constitute an endorsement.For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the World Trade Organization (WTO) prin

36、ciples in the Technical Barriers to Trade (TBT) see the following URL: www.iso.org/iso/foreword.html.This document was prepared by Technical Committee ISO/TC 76, Transfusion, infusion and injection, and blood processing equipment for medical and pharmaceutical use.This second edition cancels and rep

37、laces the first edition (ISO 6710:1995), which has been technically revised.The main changes compared to the previous edition are as follows: the Scope has been updated and phrased clearer. Blood culture bottles have been excluded from this document, as it does not address the special needs for this

38、 kind of testing; Clause 3 has been updated and extended; Clause 4 has been updated; Clause 5 has been shortened and renamed to “Draw volume”; Clause 6 has been updated; Clause 8 has been technically revised and renamed to “Sterility and special microbiological states”; Clause 9 has been extended; C

39、lause 10 has been slightly updated to meet current general requirements (except local requirements); Table 1 has been extended by additional entries for additives. It has been reduced to the specified letter codes, while the information on recommended colour codes for identifying additives has been

40、moved to a new Annex F (for clarification, see Introduction); tests in Annexes A to D have been updated in alignment with the requirements in the body of this document; Annex E has been completely revised; ISO 2017 All rights reserved vBS EN ISO 6710:2017ISO 6710:2017(E) references in Clause 2 and B

41、ibliography have been updated.vi ISO 2017 All rights reservedBS EN ISO 6710:2017ISO 6710:2017(E)IntroductionISO 6710 was first published in 1995. With the first revision starting in the year 2000, the Vienna Agreement was applied to develop the updated edition of this document in parallel between IS

42、O and CEN.However, in 2002 the parallel ballot on ISO 6710, respectively prEN ISO 6710, failed on ISO level. The ongoing development was continued only on European level and led finally to the publication of EN 14820:2004. Although, during the development, no consensus could be reached between the C

43、EN member states to add a specification for a common colour code for identifying containers with different additives.The EU commission considered the absence of colour code specifications as potential safety risk and submitted in 2006 the standardization mandate M/384 to CEN with the request to solv

44、e the issue. But even with this confirmed need it was not possible to find a consensus between the CEN members.Based on a Swedish standardization proposal in 2014, this subject was raised again and led finally to the initiation of the revision of ISO 6710:1995. The Vienna Agreement was applied in or

45、der to revise as well EN 14820:2004 with the final goal again to develop an International Standard in parallel with a harmonized European Standard.During the development, it was recognized that at least recommendations for appropriate colour code specifications should be amended. In order to avoid f

46、urther disputes on this subject, it was decided to add these recommendations in Annex F. This provides the potential users the possibility of a smooth implementation of the colour code identification without being under pressure to comply with this document in this subject. This way of introducing a

47、 common colour code allows manufacturers and/or users in healthcare to grant an evaluation phase. If there will be a higher acceptance after the publication of this document, with the next revision there is the intention to possibly move the content of Annex F to the normative part of this document.

48、In some countries, the national pharmacopoeia or other national regulations are legally binding and take precedence over this document. ISO 2017 All rights reserved viiBS EN ISO 6710:2017This page deliberately left blankSingle-use containers for human venous blood specimen collection (ISO 6710:2017)

49、1 ScopeThis document specifies requirements and test methods for evacuated and non-evacuated single-use venous blood specimen containers.It does not specify requirements for blood collection needles, needle holders, blood culture receptacles or “arterial” blood gas collection devices that can be used for venous blood.2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited appl

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 60749-33-2004 Semiconductor devices - Mechanical and climatic test methods - Part 33 Accelerated moisture resistance - Unbiased autoclave (IEC 60749-33 2004) German version .pdf DIN EN 60749-33-2004 Semiconductor devices - Mechanical and climatic test methods - Part 33 Accelerated moisture resistance - Unbiased autoclave (IEC 60749-33 2004) German version .pdf
  • DIN EN 60749-34-2011 Semiconductor devices - Mechanical and climatic test methods - Part 34 Power cycling (IEC 60749-34 2010) German version EN 60749-34 2010《半导体器件 机械和气候试验方法 第34部分 .pdf DIN EN 60749-34-2011 Semiconductor devices - Mechanical and climatic test methods - Part 34 Power cycling (IEC 60749-34 2010) German version EN 60749-34 2010《半导体器件 机械和气候试验方法 第34部分 .pdf
  • DIN EN 60749-35-2007 Semiconductor devices - Mechanical and climatic test methods - Part 35 Acoustic microscopy for plastic encapsulated electronic components (IEC 60749-35 2006) G.pdf DIN EN 60749-35-2007 Semiconductor devices - Mechanical and climatic test methods - Part 35 Acoustic microscopy for plastic encapsulated electronic components (IEC 60749-35 2006) G.pdf
  • DIN EN 60749-36-2003 Semiconductor devices - Mechanical and climatic test methods - Part 36 Acceleration steady state (IEC 60749-36 2003) German version EN 60749-36 2003《半导体器件 机械和气.pdf DIN EN 60749-36-2003 Semiconductor devices - Mechanical and climatic test methods - Part 36 Acceleration steady state (IEC 60749-36 2003) German version EN 60749-36 2003《半导体器件 机械和气.pdf
  • DIN EN 60749-37-2008 Semiconductor devices - Mechanical and climatic test methods - Part 37 Board level drop test method using an accelerometer (IEC 60749-37 2008) German version E.pdf DIN EN 60749-37-2008 Semiconductor devices - Mechanical and climatic test methods - Part 37 Board level drop test method using an accelerometer (IEC 60749-37 2008) German version E.pdf
  • DIN EN 60749-38-2008 Semiconductor devices - Mechanical and climatic test methods - Part 38 Soft error test method for semiconductor devices with memory (IEC 60749-38 2008) German .pdf DIN EN 60749-38-2008 Semiconductor devices - Mechanical and climatic test methods - Part 38 Soft error test method for semiconductor devices with memory (IEC 60749-38 2008) German .pdf
  • DIN EN 60749-39-2007 Semiconductor devices - Mechanical and climatic test methods - Part 39 Measurement of moisture diffusivity and water solubility in organic materials used for s.pdf DIN EN 60749-39-2007 Semiconductor devices - Mechanical and climatic test methods - Part 39 Measurement of moisture diffusivity and water solubility in organic materials used for s.pdf
  • DIN EN 60749-4-2017 Semiconductor devices - Mechanical and climatic test methods - Part 4 Damp heat steady state highly accelerated stress test (HAST) (IEC 60749-4 2017) German ver.pdf DIN EN 60749-4-2017 Semiconductor devices - Mechanical and climatic test methods - Part 4 Damp heat steady state highly accelerated stress test (HAST) (IEC 60749-4 2017) German ver.pdf
  • DIN EN 60749-40-2012 Semiconductor devices - Mechanical and climatic test methods - Part 40 Board level drop test method using a strain gauge (IEC 60749-40 2011) German version EN .pdf DIN EN 60749-40-2012 Semiconductor devices - Mechanical and climatic test methods - Part 40 Board level drop test method using a strain gauge (IEC 60749-40 2011) German version EN .pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1