1、BRITISH STANDARDBS EN ISO 10077-1:2006Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: GeneralThe European Standard EN ISO 10077-1:2006 has the status of a British StandardICS 91.060.50; 91.120.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37
2、g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN ISO 10077-1:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2006 BSI 2006ISBN
3、 0 580 49527 2National forewordThis British Standard was published by BSI. It is the UK implementation of EN ISO 10077-1:2006. It supersedes BS EN ISO 10077-1:2000 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee B/540, Energy performance of materials
4、components and buildings.A list of organizations represented on B/540 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confe
5、r immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 10077-1September 2006ICS 91.120.10; 91.060.50 Supersedes EN ISO 10077-1:2000 English VersionThermal performance of windows, doors and shutters -Calculation
6、 of thermal transmittance - Part 1: General (ISO10077-1:2006)Performance thermique des fentres, portes et fermetures -Calcul du coefficient de transmission thermique - Partie 1:Gnralits (ISO 10077-1:2006)Wrmetechnisches Verhalten von Fenstern, Tren undAbschlssen - Berechnung desWrmedurchgangskoeffiz
7、ienten - Teil 1: Allgemeines (ISO10077-1:2006)This European Standard was approved by CEN on 2 August 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration
8、. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationun
9、der the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Icel
10、and, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stas
11、sart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 10077-1:2006: EForeword This document (EN ISO 10077-1:2006) has been prepared by Technical Committee ISO/TC 163 “Thermal insulation“ in collaboration w
12、ith Technical Committee CEN/TC 89 “Thermal performance of buildings and building components“, the secretariat of which is held by SIS. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2007, a
13、nd conflicting national standards shall be withdrawn at the latest by March 2007. This document supersedes EN ISO 10077-1:2000. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, B
14、elgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Endorsement notice The text o
15、f ISO 10077-1:2006 has been approved by CEN as EN ISO 10077-1:2006 without any modifications. EN ISO 10077-1:2006Reference numberISO 10077-1:2006(E)INTERNATIONAL STANDARD ISO10077-1Second edition2006-09-15Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1:
16、 General Performance thermique des fentres, portes et fermetures Calcul du coefficient de transmission thermique Partie 1: Gnralits EN ISO 10077-1:2006ii iiiContents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references . 2 3 Terms, definitions, symbols and units . 2 3.1 Terms and defin
17、itions. 2 3.2 Symbols and units 3 3.3 Subscripts . 3 4 Geometrical characteristics. 3 4.1 Glazed area, opaque panel area 3 4.2 Total visible perimeter of the glazing . 3 4.3 Frame areas. 4 4.4 Window area 4 5 Calculation of thermal transmittance . 6 5.1 Windows 6 5.2 Glazing . 9 5.3 Windows with clo
18、sed shutters 10 5.4 Doors 11 6 Input data. 13 7 Report 13 7.1 Contents of report. 13 7.2 Drawing of sections 13 7.3 Drawing of the whole window or door 14 7.4 Values used in the calculation 14 7.5 Presentation of results. 14 Annex A (normative) Internal and external surface thermal resistances. 15 A
19、nnex B (normative) Thermal conductivity of glass 16 Annex C (informative) Thermal resistance of air spaces between glazing and thermal transmittance of coupled, double or triple glazing . 17 Annex D (informative) Thermal transmittance of frames . 19 Annex E (normative) Linear thermal transmittance o
20、f frame/glazing junction 25 Annex F (informative) Thermal transmittance of windows 27 Annex G (informative) Additional thermal resistance for windows with closed shutters 32 Annex H (informative) Permeability of shutters 33 Bibliography . 35 EN ISO 10077-1:2006iv Foreword ISO (the International Orga
21、nization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been establis
22、hed has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization
23、. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. P
24、ublication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such pate
25、nt rights. ISO 10077-1 was prepared by Technical Committee ISO/TC 163, Thermal performance and energy use in the built environment, Subcommittee SC 2, Calculation methods. This second edition cancels and replaces the first edition (ISO 10077-1:2000), the following clauses and subclauses of which hav
26、e been technically revised. Clause Changes Introduction Added new paragraph explaining the various parts of the overall thermal transmittance 1 Amended 4th paragraph to permit calculation of U-value of roof windows 2 References to ISO rather than EN ISO where applicable 4.3 Added “including sashes i
27、f present” to the definition of areas 4.4 Clarification that sealing gaskets are ignored in the determination of areas. Dimensions to be measured to nearest mm. 5.1.1 Third from last paragraph inserted concerning roof windows 5.3 Data on shutters moved to Annex G 6 Added paragraph to say that declar
28、ed values are to be obtained for horizontal heat flow (as in ISO 10292 and EN 673) 7.1 Second dash, drawing to give details also for metal frames Table A.1 Added surface resistance values for horizontal or inclined window Annex E Complete revision of Annex E. It has been changed to normative, becaus
29、e it provides default values that are to be used in the absence of detailed values. Annex F Complete revision of Annex F, using the new values in Annex E ISO 10077 consists of the following parts, under the general title Thermal performance of windows, doors and shutters Calculation of thermal trans
30、mittance: Part 1: General Part 2: Numerical method for frames EN ISO 10077-1:2006vIntroduction The calculation method described in this part of ISO 10077 is used to evaluate the thermal transmittance of windows and doors, or as part of the determination of the energy use of a building. An alternativ
31、e to calculation is testing of the complete window or door according to ISO 12567-1 or, for roof windows, according to ISO 12567-2. The calculation is based on four component parts of the overall thermal transmittance: for elements containing glazing, the thermal transmittance of the glazing, calcul
32、ated using EN 673 or measured according to EN 674 or EN 675; for elements containing opaque panels, the thermal transmittance of the opaque panels, calculated according to ISO 6946 and/or ISO 10211 (all parts) or measured according to ISO 8301 or ISO 8202; thermal transmittance of the frame, calcula
33、ted using ISO 10077-2, measured according to EN 12412-2, or taken from Annex D of this part of ISO 10077; linear thermal transmittance of the frame/glazing junction, calculated according to ISO 10077-2 or taken from Annex E of this part of ISO 10077. More detailed equations for calculation of heat f
34、low through windows can be found in ISO 15099. The thermal transmittance of curtain walling can be calculated using prEN 13947. EN 13241-1 gives procedures applicable to doors intended to provide access for goods and vehicles. EN ISO 10077-1:2006blank1Thermal performance of windows, doors and shutte
35、rs Calculation of thermal transmittance Part 1: General 1 Scope This part of ISO 10077 specifies methods for the calculation of the thermal transmittance of windows and pedestrian doors consisting of glazed and/or or opaque panels fitted in a frame, with and without shutters. This part of ISO 10077
36、allows for different types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and with spaces filled with air or other gases); opaque panels within the window or door; various types of frames (wood, plastic, metallic with and without thermal barrier, m
37、etallic with pinpoint metallic connections or any combination of materials); where appropriate, the additional thermal resistance introduced by different types of closed shutter, depending on their air permeability. The thermal transmittance of roof windows and other projecting windows can be calcul
38、ated according to this part of ISO 10077, provided that the thermal transmittance of their frame sections is determined by measurement or by numerical calculation. Default values for glazing, frames and shutters are given in the informative annexes. Thermal bridge effects at the rebate or joint betw
39、een the window or door frame and the rest of the building envelope are excluded from the calculation. The calculation does not include effects of solar radiation, heat transfer caused by air leakage, calculation of condensation, ventilation of air spaces in double and coupled windows, surrounding pa
40、rts of an oriel window. The part of ISO 10077 does not apply to curtain walls and other structural glazing, industrial, commercial and garage doors. EN ISO 10077-1:20062 2 Normative references The following referenced documents are indispensable for the application of this document. For dated refere
41、nces, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 6946, Building components and building elements Thermal resistance and thermal transmittance Calculation method ISO 7345, Thermal insulation Physical qu
42、antities and definitions ISO 8301, Thermal insulation Determination of steady-state thermal resistance and related properties Heat flow meter apparatus ISO 8302, Thermal insulation Determination of steady-state thermal resistance and related properties Guarded hot plate apparatus ISO 10077-2, Therma
43、l performance of windows, doors and shutters Calculation of thermal transmittance Part 2: Numerical method for frames ISO 10211 (all parts), Thermal bridges in building construction Heat flows and surface temperatures Detailed calculations ISO 12567-2, Thermal performance of windows and doors Determ
44、ination of thermal transmittance by hot box method Part 2: Roof windows and other projecting windows EN 673, Glass in building Determination of thermal transmittance (U value) Calculation method EN 674, Glass in building Determination of thermal transmittance (U value) Guarded hot plate method EN 67
45、5, Glass in building Determination of thermal transmittance (U value) Heat flow meter method EN 12412-2, Thermal performance of windows, doors and shutters Determination of thermal transmittance by hot box method Part 2: Frames 3 Terms, definitions, symbols and units 3.1 Terms and definitions For th
46、e purposes of this document, the terms and definitions given in EN 673 and ISO 7345 apply. In Clause 4 of this part of ISO 10077, descriptions are given of a number of geometrical characteristics of glazing and frame. EN ISO 10077-1:200633.2 Symbols and units Symbol Quantity Unit A area m2R thermal
47、resistance m2K/W U thermal transmittance W/(m2K) b width md distance, thickness m l length mq density of heat flow rate W/m2 linear thermal transmittance W/(mK) thermal conductivity W/(mK) 3.3 Subscripts D door i internal W window j summation index WS window with closed shutter p panel (opaque) d de
48、veloped s space (air or gas space) e external se external surface f frame sh shutter g glazing si internal surface 4 Geometrical characteristics 4.1 Glazed area, opaque panel area The glazed area, Ag, or the opaque panel area, Ap, of a window or door is the smaller of the visible areas seen from bot
49、h sides; see Figure 1. Any overlapping of gaskets is ignored. 4.2 Total visible perimeter of the glazing The total perimeter of the glazing, lg, (or the opaque panel, lp) is the sum of the visible perimeter of the glass panes (or opaque panels) in the window or door. If the perimeters are different on either side of the pane or panel, then the larger of the two shall be used; see Figure 1. Key 1 glass Figure 1 Illustration of glazed area and perimeter EN ISO 10077-1:200