1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN ISO 12543-5:2011Glass in building Laminated glass and laminated safety glass Part 5: Dimensions and edge finishing (ISO 12543-5:2011)BS EN ISO 12543-5:2011 BRITISH STANDARD
2、National forewordThis British Standard is the UK implementation of EN ISO 12543-5:2011. It supersedes BS EN ISO 12543-5:1998 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/520/1, Basic and transformed glass products.A list of organizations represent
3、ed on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0 580 60146 0 ICS 81.040.20 Compliance with a British Standard cannot confer
4、immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2011.Amendments issued since publicationDate T e x t a f f e c t e dEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 12543-5 August 2011 ICS 81.
5、040.20 Supersedes EN ISO 12543-5:1998English Version Glass in building - Laminated glass and laminated safety glass -Part 5: Dimensions and edge finishing (ISO 12543-5:2011) Verre dans la construction - Verre feuillet et verre feuillet de scurit - Partie 5: Dimensions et faonnage des bords (ISO 1254
6、3-5:2011) Glas im Bauwesen - Verbundglas und Verbund-Sicherheitsglas - Teil 5: Mae und Kantenbearbeitung (ISO 12543-5:2011) This European Standard was approved by CEN on 6 August 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving
7、 this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three offici
8、al versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of A
9、ustria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. E
10、UROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 12543-5:2011: EBS EN
11、ISO 12543-5:2011EN ISO 12543-5:2011 (E) 3 Foreword This document (EN ISO 12543-5:2011) has been prepared by Technical Committee ISO/TC 160 “Glass in building“ in collaboration with Technical Committee CEN/TC 129 “Glass in building” the secretariat of which is held by NBN. This European Standard shal
12、l be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2012, and conflicting national standards shall be withdrawn at the latest by February 2012. Attention is drawn to the possibility that some of the elements of this do
13、cument may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN ISO 12543-5:1998. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries
14、 are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
15、 Spain, Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 12543-5:2011 has been approved by CEN as a EN ISO 12543-5:2011 without any modification. BS EN ISO 12543-5:2011ISO 12543-5:2011(E) ISO 2011 All rights reserved iiiForeword ISO (the International Organization for S
16、tandardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the ri
17、ght to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Internationa
18、l Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as
19、an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO
20、 12543-5 was prepared by Technical Committee ISO/TC 160, Glass in building, Subcommittee SC 1, Product considerations. This second edition cancels and replaces the first edition (ISO 12543-5:1998), which has been technically revised. ISO 12543 consists of the following parts, under the general title
21、 Glass in building Laminated glass and laminated safety glass: Part 1: Definitions and description of component parts Part 2: Laminated safety glass Part 3: Laminated glass Part 4: Test methods for durability Part 5: Dimensions and edge finishing Part 6: Appearance BS EN ISO 12543-5:2011BS EN ISO 12
22、543-5:2011INTERNATIONAL STANDARD ISO 12543-5:2011(E) ISO 2011 All rights reserved 1Glass in building Laminated glass and laminated safety glass Part 5: Dimensions and edge finishing 1 Scope This part of ISO 12543 specifies dimensions, limit deviations and edge finishes of laminated glass and laminat
23、ed safety glass for use in building. This part of ISO 12543 is not applicable to panes having an area less than 0,05 m2. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated
24、 references, the latest edition of the referenced document (including any amendments) applies. ISO 12543-1, Glass in building Laminated glass and laminated safety glass Part 1: Definitions and description of component parts 3 Terms and definitions For the purposes of this document, the terms and def
25、initions given in ISO 12543-1 and the following apply. 3.1 displacement d misalignment at any one edge of the constituent glass panes or plastic glazing sheet material making up the laminated glass See Figure 2. 4 Dimensions and limit deviations 4.1 Thickness 4.1.1 Nominal thickness The nominal thic
26、kness of laminated glass shall be the sum of the nominal thicknesses of the constituent panes of glass, plastic glazing sheet material and the interlayers. BS EN ISO 12543-5:2011ISO 12543-5:2011(E) 2 ISO 2011 All rights reserved4.1.2 Limit deviation on thickness 4.1.2.1 Limit deviation on thickness
27、of folio laminated products The limit deviations on thickness of laminated glass shall not exceed the sum of the limit deviations of the constituent glass panes specified in the basic products standards; see ISO 12543-1:2011, Annex A. NOTE 1 For the appropriate CEN standards, see ISO 12543-1:2011, A
28、nnex B. If the total interlayer thickness is less than or equal to 2 mm, an additional limit deviation of 0,1 mm applies. If the total interlayer thickness is greater than 2 mm, an additional limit deviation of 0,2 mm shall apply. The thickness limit deviation for plastic glazing sheet material shal
29、l be assumed to be the same as a float glass of the same nominal thickness. NOTE 2 If the plastic glazing sheet material is covered by a standard, the actual limit deviations on thickness can be used. EXAMPLE A laminated glass made from two sheets of float glass of 3 mm nominal thickness and a folio
30、 interlayer of 0,5 mm. The limit deviation of 3 mm float glass is given as 0,2 mm and the limit deviation of the folio interlayer is 0,1 mm. Therefore, the nominal thickness is 6,5 mm and the limit deviation is 0,5 mm. 4.1.2.2 Limit deviations on thickness of cast-in-place products The limit deviati
31、ons on thickness of cast-in-place laminated glass shall not exceed the sum of the limit deviations of the constituent glass panes specified in the basic products standards and the limit deviations of the cast-in-place interlayers. The thickness limit deviation for plastic glazing sheet material shal
32、l be assumed to be the same as a float glass of the same nominal thickness. NOTE If the plastic glazing sheet material is covered by a standard, the actual limit deviations on thickness can be used. The thickness limit deviations of cast-in-place interlayers shall be in accordance with Table 1. Tabl
33、e 1 Limit deviations on thickness of cast-in-place interlayers Dimensions in millimetres Interlayer thickness Limit deviation 8 mm Nominal dimension L or H Nominal thickness of laminated glass 8 mm Each glass pane 3 000 +5,0 3,0 +6,0 4,0 +7,0 5,0 The limit deviations given in Table 3 do not apply fo
34、r fire-resistant laminated glass and fire-resistant laminated safety glass. In these cases, the manufacturer shall specify the limit deviations. The limit deviations, v, for the difference between diagonals are given in Table 4. Table 4 Limit deviations, v, on the difference between diagonals Dimens
35、ions in millimetres Nominal thickness of laminated glass 8 mm Nominal dimension L or H Nominal thickness of laminated glass 8 mm Each glass pane 3 000 10 11 13 4.2.4 Displacement Figure 2 Displacement BS EN ISO 12543-5:2011ISO 12543-5:2011(E) 6 ISO 2011 All rights reservedThe maximum displacement, d
36、, shall be as specified in Table 5. Width, L, and length, H, shall be considered separately. Table 5 Maximum displacement, d, for cut sizes and stock sizes Dimensions in millimetres Nominal dimension L or H Maximum permissible displacement d L, H 1 000 1 000 4 000 2,0 3,0 4,0 6,0 5 Edge finishes 5.1
37、 General Thermally treated glasses shall not be cut, sawn, drilled or edge worked after making into a laminate. NOTE Thermally toughened safety glass, heat-soaked thermally toughened safety glass and heat-strengthened glass can be individually worked prior to thermal treatment in accordance with an
38、applicable standard. The edges of fire-resistant laminated glass and fire-resistant laminated safety glass can be protected by an adhesive tape. 5.2 Cut edge These are either originally cut edges of the constituent glass panes not subsequently worked (see Figure 3), or the edges of the laminated gla
39、ss which have been cut and not subsequently worked (see Figure 4). Figure 3 Cut edge produced by the individual cut edges of the constituent glass panes which are not subsequently worked Figure 4 Cut edge of cut laminated glass which is not subsequently worked BS EN ISO 12543-5:2011ISO 12543-5:2011(
40、E) ISO 2011 All rights reserved 75.3 Worked edges 5.3.1 Arrissed edge The originally cut edges of the outer glass panes of the laminated glass shall be ground off (see Figure 5). Figure 5 Arrissed edge 5.3.2 Ground edge The glass shall be arrissed and flat ground (see Figure 6). NOTE Some bright are
41、as can still exist on the edge face. Figure 6 Ground edge 5.3.3 Smooth ground edge The edge face of the arrissed glass shall be ground and then smoothed with a finer grit than is used for ground edges and all bright areas shall be removed (see Figure 7). Figure 7 Smooth ground edge BS EN ISO 12543-5
42、:2011ISO 12543-5:2011(E) 8 ISO 2011 All rights reserved5.3.4 Polished edge The previously smooth ground edge shall be polished in order to obtain a high lustre on the arrissed and smoothed edges surface (see Figure 8). Figure 8 Polished edge 5.3.5 Bevel edge A bevel edge shall be a smooth ground or
43、polished edge with an angle not exceeding 60. The limit deviation on a bevel angle shall be 3 (see Figure 9). For greater angles and their limit deviations, the manufacturer should be contacted. The nominal dimension, L or H, shall be reduced by 2 mm to 3 mm to cater for an arrissed edge. Dimensions
44、 in millimetres Figure 9 Bevel edge 5.3.6 Sawn edge A sawn edge shall be obtained by cutting with a saw. NOTE The appearance is similar to ground edges, but without bright spots and arrissing. 5.3.7 Water jet cut edge A water jet cut edge shall be obtained by cutting with a water jet. NOTE The appea
45、rance is similar to ground edges, but without bright spots and arrissing. BS EN ISO 12543-5:2011ISO 12543-5:2011(E) ISO 2011 All rights reserved 96 Flatness The flatness of laminated glass is dependent on the flatness of the constituent parts and can be influenced by the manufacturing conditions. Fo
46、r the flatness of final cut sizes of folio laminated glass, ask the manufacturer. This page deliberately left blankThis page deliberately left blankBSI is the independent national body responsible for preparing British Standardsand other standards-related publications, information and services. It p
47、resents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards are updated b
48、y amendment or revision. Users of British Stan-dards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and serv-ices. We would be grateful if anyone finding an inaccuracy or ambiguity whileusing this British Stan
49、dard would inform the Secretary of the technical com-mittee responsible, the identity of which can be found on the inside frontcover.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers Members an individual updating service called PLUS which ensuresthat subscribers automatically receive the latest editions of standards.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard