EN ISO 15875-1-2003 en Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 1 General (Incorporates Amendment A1 2007)《冷热水装置用塑料管道系统.pdf

上传人:arrownail386 文档编号:725746 上传时间:2019-01-09 格式:PDF 页数:18 大小:304.92KB
下载 相关 举报
EN ISO 15875-1-2003 en Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 1 General (Incorporates Amendment A1 2007)《冷热水装置用塑料管道系统.pdf_第1页
第1页 / 共18页
EN ISO 15875-1-2003 en Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 1 General (Incorporates Amendment A1 2007)《冷热水装置用塑料管道系统.pdf_第2页
第2页 / 共18页
EN ISO 15875-1-2003 en Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 1 General (Incorporates Amendment A1 2007)《冷热水装置用塑料管道系统.pdf_第3页
第3页 / 共18页
EN ISO 15875-1-2003 en Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 1 General (Incorporates Amendment A1 2007)《冷热水装置用塑料管道系统.pdf_第4页
第4页 / 共18页
EN ISO 15875-1-2003 en Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 1 General (Incorporates Amendment A1 2007)《冷热水装置用塑料管道系统.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN ISO 15875-1:2003Incorporating amendment no. 1Plastics piping systems for hot and cold water installations Crosslinked polyethylene (PE-X) Part 1: GeneralThe European Standard EN ISO 15875-1:2003, incorporating amendment A1:2007, has the status of a British StandardICS 23.040.01

2、; 91.140.60g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN ISO 15875-1:2003This British Standard was published under the authority of the Stan

3、dards Policy and Strategy Committee on 14 June 2004 BSI 2007ISBN 978 0 580 59877 7National forewordThis British Standard is the UK implementation of EN ISO 15875-1:2003, incorporating amendment A1:2007. It is identical with ISO 15875-1:2003, incorporating amendment 1:2007.The UK participation in its

4、 preparation was entrusted by Technical Committee PRI/88, Plastics piping systems, to Subcommittee PRI/88/2, Plastics piping systems for pressure applications.A list of organizations represented on this subcommittee can be obtained on request to its secretary.Additional informationThe UK voted again

5、st the acceptance of this standard at the CEN Formal Vote, and PRI 88/2 will maintain BS 7291-1:20011), BS 7291-2:20012)and BS 7291-3:20013)and strongly recommends the continued use of polybutylene (PB) and crosslinked polyethylene (PE-X) piping systems certified to BS 7291-2 or BS 7291-3, Class S,

6、for the following reasons.a) Attention is drawn to the statement in the Scope of this standard relating to the exclusion from it of piping systems having service conditions in excess of those quoted in Table 1. Central heating systems in the UK fall into this category. BS 7291-1 states the service c

7、onditions for UK systems where the maximum system service temperature for sealed central heating systems, designated as Class S, is 105 C and the system malfunction temperature is 114 C. Both these temperatures are significantly in excess of those specified in Table 1 and these UK systems are theref

8、ore not covered by this standard.1)BS 7291-1:2001, Thermoplastics pipes and associated fittings for hot and cold water for domestic purposes and heating installations in buildings Part 1: General requirements.2)BS 7291-2:2001, Thermoplastics pipes and associated fittings for hot and cold water for d

9、omestic purposes and heating installations in buildings Part 2: Specification for polybutylene (PB) pipes and associated fittings.3)BS 7291-3:2001, Thermoplastics pipes and associated fittings for hot and cold water for domestic purposes and heating installations in buildings Part 3: Specification f

10、or cross-linked polyethylene (PE-X) pipes and associated fittings.Amendments issued since publicationAmd. No. Date Comments17244 31 July 2007 The definition for 3.1.4 has been replaced. References 58 have been added to the Bibliography.BS EN ISO 15875-1:2003 BSI 2007ib) In addition to the above:1) T

11、he normal maximum operating cold water supply pressure in the UK is 12.5 bar4)which some categories of piping systems in the BS EN ISO 15875 series of standards do not meet.2) The BS EN ISO 15875 series of standards does not specifically describe push fit joints, which are the predominant jointing m

12、ethod in the UK.3) There is a disparity between the malfunction temperature quoted in Table 1 (100 C) and the malfunction temperatures applicable to boilers (110 C) conforming to BS EN 297:19945), BS EN 483:20006)and BS EN 625:19967). Consequently piping systems could be subjected to temperatures in

13、 service for which they have not been tested.4) The unique and traditional practice in the UK is to use products certified to BS 7291-2 or BS 7291-3, Class S, for all applications, as defined in BS 7291-1. This is recognized in the national annex to BS EN 128288), which recommends the use of systems

14、 suitable for the maximum temperatures and pressures for their intended application specified in BS 7291-1.Updated versions of BS 7291-1, BS 7291-2 and BS 7291-3 are being prepared, which maintain these traditional UK operating conditions, and measures are being taken to address this issue in approp

15、riate harmonized European Standards.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.4)1 bar = 100 kPa.5)BS EN 297:1994, Gas-fire

16、d central heating boilers Type B11and B11BSboilers fitted with atmospheric burners of nominal heat input not exceeding 70 kW.6)BS EN 483:2000, Gas-fired central heating boilers Type C boilers of nominal heat input not exceeding 70 kW.7)BS EN 625:1996, Gas-fired central heating boilers Specific requi

17、rements for the domestic hot water operation of combination boilers of nominal heat input not exceeding 70 kW.8)BS EN 12828, Heating systems in buildings Design for water-based heating systems.iiblankEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 15875-1December 2003ICS 23.040.01; 91.140.60En

18、glish versionPlastics piping systems for hot and cold water installations -Crosslinked polyethylene (PE-X) - Part 1: General (ISO 15875-1:2003)Systmes de canalisations en plastique pour lesinstallations deau chaude et froide - Polythylne rticul(PE-X) - Partie 1: Gnralits (ISO 15875-1:2003)Kunststoff

19、-Rohrleitungssysteme fr die Warm- undKaltwasserinstallation - Vernetztes Polyethylen (PE-X) -Teil 1: Allgemeines (ISO 15875-1:2003)This European Standard was approved by CEN on 14 March 2003.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for

20、giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versio

21、ns (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech R

22、epublic, Denmark, Finland, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and UnitedKingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement C

23、entre: rue de Stassart, 36 B-1050 Brussels 2003 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 15875-1:2003 E+ A1June 2007EN ISO 15875-1:2003 (E)2ContentsContents. 2Introduction . 41 Scope 52 Normative references 53 Terms and de

24、finitions, symbols and abbreviated terms. 53.1 Terms and definitions. 53.1.1 Geometrical terms and definitions 53.1.2 Terms and definitions related to service conditions. 73.1.3 Terms and definitions related to material characteristics. 83.2 Symbols 83.3 Abbreviated terms 94 Classification of servic

25、e conditions 95 Material. 105.1 General. 105.2 Influence on water intended for human consumption 105.3 Reprocessable material . 11Bibliography 12EN ISO 15875-1:2003 (E)3ForewordThis document (EN ISO 15875-1:2003) has been prepared by Technical Committee CEN/TC 155 “Plastics pipingsystems and ducting

26、 systems”, the secretariat of which is held by NEN, in collaboration with Technical CommitteeISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids“.NOTE This standard was submitted for CEN enquiry as prEN 12318-1:1996.This European Standard shall be given the status of a nation

27、al standard, either by publication of an identical text orby endorsement, at the latest by June 2004, and conflicting national standards shall be withdrawn at the latest byDecember 2005.This standard is part of a System Standard for plastics piping systems of a particular material for a specifiedapp

28、lication. There are a number of such System Standards.System Standards are based on the results of the work undertaken in ISO/TC 138 “Plastics pipes, fittings andvalves for the transport of fluids“, which is a Technical Committee of the International Organization forStandardization (ISO).They are su

29、pported by separate standards on test methods to which references are made throughout the SystemStandard.The System Standards are consistent with general standards on functional requirements and recommendedpractices for installation.EN ISO 15875:2003 consists of the following Parts1), under the gene

30、ral title Plastics piping systems for hot andcold water installations Crosslinked polyethylene (PE-X) Part 1: General (the present standard) Part 2: Pipes Part 3: Fittings Part 5: Fitness for purpose of the system Part 7: Guidance for the assessment of conformity (CEN ISO/TS 15875-7).This Part of EN

31、 ISO 15875 includes a Bibliography.At the date of publication of this standard, System Standards for piping systems of other plastics materials used forthe same application are the following:EN ISO 15874, Plastics piping systems for hot and cold water installations Polypropylene (PP)(ISO 15874:2003)

32、EN ISO 15876, Plastics piping systems for hot and cold water installations Polybutylene (PB) (ISO 15876:2003)EN ISO 15877, Plastics piping systems for hot and cold water installations Chlorinated poly(vinyl chloride)(PVC-C) (ISO 15877:2003)For pipes and fittings which have conformed to the relevant

33、national standard before 1stNovember 2003, as shownby the manufacturer or by a certification body, the national standard may continue to apply until 30thNovember2005According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implemen

34、t this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,Slovakia, Spain, Sweden, Switzerland and the United Kingdom.1) This System Standard does not incorporate a Part 4 A

35、ncillary equipment or a Part 6 Guidance for installation. For ancillaryequipment separate standards can apply. Guidance on installation of plastics piping systems made from different materialsintended to be used for hot and cold water installations is given by ENV 12108:20011.EN ISO 15875-1:2003 (E)

36、4IntroductionThe System Standard, of which this is Part 1, specifies the requirements for a piping system when made fromcrosslinked polyethylene (PE-X). The piping system is intended to be used for hot and cold water installations.In respect of potential adverse effects on the quality of water inten

37、ded for human consumption, caused by theproduct covered by EN ISO 15875: This standard provides no information as to whether the product may be used without restriction in any of theMember States of the EU or EFTA; It should be noted that, while awaiting the adoption of verifiable European criteria,

38、 existing national regulationsconcerning the use and/or the characteristics of this product remain in force.Requirements and test methods for components of the piping system are specified in Part 2 and Part 3 ofEN ISO 15875:2003. Characteristics for fitness of purpose (mainly for joints) are covered

39、 in Part 5. Part 7(CEN ISO/TS 15875-7) gives guidance for the assessment of conformity.This Part of EN ISO 15875 specifies the general aspects of the plastics piping system.Foreword to amendment A1This document (EN ISO 15875-1:2003/A1:2007) has been prepared by Technical Committee CEN/TC 155 “Plasti

40、cs piping systems and ducting systems“, the secretariat of which is held by NEN, in collaboration with Technical Committee ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids“. This European Standard shall be given the status of a national standard, either by publication of a

41、n identical text or by endorsement, at the latest by December 2007, and conflicting national standards shall be withdrawn at the latest by December 2007. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this Eur

42、opean Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Ki

43、ngdom. EN ISO 15875-1:2003 (E)51 ScopeThis Part of EN ISO 15875 specifies the general aspects of crosslinked polyethylene (PE-X) piping systemsintended to be used for hot and cold water installations within buildings for the conveyance of water, whether or notintended for human consumption (domestic

44、 systems), and for heating systems, under design pressures andtemperatures according to the class of application (see Table 1).This standard covers a range of service conditions (application classes) and design pressure and pipe dimensionclasses. For values of TD, Tmaxand Tmalin excess of those in T

45、able 1, this standard does not apply.NOTE It is in the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account theirparticular requirements and any relevant national regulations and installation practices or codes.It also specifies the

46、test parameters for the test methods referred to in this standard.In conjunction with the other Parts of EN ISO 15875 (see Foreword) it is applicable to PE-X pipes, fittings, theirjoints and to joints with components of other plastics and non-plastics materials intended to be used for hot andcold wa

47、ter installations.2 Normative referencesThis Standard incorporates by dated or undated reference, provisions from other publications. These normativereferences are cited at the appropriate places in the text and the publications are listed hereafter. For datedreferences, subsequent amendments to or

48、revisions of any of these publications apply to this Standard only whenincorporated in it by amendment or revision. For undated references the latest edition of the publication referred toapplies (including amendments).EN ISO 15875-2:2003, Plastics piping systems for hot and cold water installations

49、 Crosslinked polyethylene(PE-X) Part 2: Pipes (ISO 15875-2:2003)EN ISO 15875-3:2003, Plastics piping systems for hot and cold water installations Crosslinked polyethylene(PE-X) Part 3: Fittings (ISO 15875-3:2003)ISO 472:1999, Plastics VocabularyISO 1043-1:2001, Plastics Symbols and abbreviated terms Part 1: Basic polymers and their specialcharacteristics3 Terms and definitions, symbols and abbreviated termsFor the purposes of this standard, the following terms and definitions, symbols and abbreviated terms apply.3

展开阅读全文
相关资源
猜你喜欢
  • EN 60604-1993 en Topflash Flipflash- Photographic Flash Lamp Array《顶光闪光 翻转闪光照相闪光灯组(IEC 604-1980)》.pdf EN 60604-1993 en Topflash Flipflash- Photographic Flash Lamp Array《顶光闪光 翻转闪光照相闪光灯组(IEC 604-1980)》.pdf
  • EN 60609-1-2005 en Hydraulic turbines storage pumps and pump-turbines Cavitation pitting evaluation Part 1 Evaluation in reaction turbines storage pumps and pump-turbines《水轮机 蓄能泵和水.pdf EN 60609-1-2005 en Hydraulic turbines storage pumps and pump-turbines Cavitation pitting evaluation Part 1 Evaluation in reaction turbines storage pumps and pump-turbines《水轮机 蓄能泵和水.pdf
  • EN 60609-2-1999 en Cavitation pitting evaluation in hydraulic turbines storage pumps and pump-turbines Part 2 Evaluation in Pelton turbines《水轮机蓄能泵和水泵水轮机气蚀损坏的评定 第2部分 水斗式水轮机的评定 IEC 6.pdf EN 60609-2-1999 en Cavitation pitting evaluation in hydraulic turbines storage pumps and pump-turbines Part 2 Evaluation in Pelton turbines《水轮机蓄能泵和水泵水轮机气蚀损坏的评定 第2部分 水斗式水轮机的评定 IEC 6.pdf
  • EN 60613-2010 en Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis《医疗诊断用X射线管组件的电气和负载特性》.pdf EN 60613-2010 en Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis《医疗诊断用X射线管组件的电气和负载特性》.pdf
  • EN 60618-1997 en Inductive Voltage Dividers (Incorporates Amendment A2 1997)《感应分压器 包含修改件A2-1997[替代 CENELEC HD 390 S2]》.pdf EN 60618-1997 en Inductive Voltage Dividers (Incorporates Amendment A2 1997)《感应分压器 包含修改件A2-1997[替代 CENELEC HD 390 S2]》.pdf
  • EN 60619-1993 en Electrically operated food preparation appliances Methods for measuring the performance (Incorporates Amendments A1 1995 and A2 2004)《电动食品加工机 性能测试方法 包含修改件A1-1995和A.pdf EN 60619-1993 en Electrically operated food preparation appliances Methods for measuring the performance (Incorporates Amendments A1 1995 and A2 2004)《电动食品加工机 性能测试方法 包含修改件A1-1995和A.pdf
  • EN 60622-2003 en Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells《含碱性或其它非酸性电解液的副电池和蓄电池 密.pdf EN 60622-2003 en Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells《含碱性或其它非酸性电解液的副电池和蓄电池 密.pdf
  • EN 60623-2017 en Secondary cells and batteries containing alkaline or other nonacid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells.pdf EN 60623-2017 en Secondary cells and batteries containing alkaline or other nonacid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells.pdf
  • EN 60626-1-2012 en Combined flexible materials for electrical insulation - Part 1 Definitions and general requirements.pdf EN 60626-1-2012 en Combined flexible materials for electrical insulation - Part 1 Definitions and general requirements.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1