ETSI ES 202 336-5-2010 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm.pdf

上传人:priceawful190 文档编号:730916 上传时间:2019-01-08 格式:PDF 页数:18 大小:99.80KB
下载 相关 举报
ETSI ES 202 336-5-2010 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm.pdf_第1页
第1页 / 共18页
ETSI ES 202 336-5-2010 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm.pdf_第2页
第2页 / 共18页
ETSI ES 202 336-5-2010 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm.pdf_第3页
第3页 / 共18页
ETSI ES 202 336-5-2010 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm.pdf_第4页
第4页 / 共18页
ETSI ES 202 336-5-2010 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、 ETSI ES 202 336-5 V1.1.1 (2010-04)ETSI Standard Environmental Engineering (EE);Monitoring and Control Interface for Infrastructure Equipment(Power, Cooling and Building Environment Systemsused in Telecommunication Networks);Part 5: AC diesel back-up generator system control andmonitoring informatio

2、n modelETSI ETSI ES 202 336-5 V1.1.1 (2010-04)2Reference DES/EE-02037-5 Keywords control, interface, management, power, system ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non

3、lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived differ

4、ence in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware tha

5、t the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/po

6、rtal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2010. All rights reserved. DECTTM, PLU

7、GTESTSTM, UMTSTM, TIPHONTM, the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. LTE is a Trade Mark of ETSI currently being registered fo

8、r the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI ES 202 336-5 V1.1.1 (2010-04)3Contents Intellectual Property Rights 4g3Foreword . 4g31 Scope 5g32 References 5g32.1 Normative references .

9、 5g32.2 Informative references 6g33 Definitions and abbreviations . 6g33.1 Definitions 6g33.2 Abbreviations . 8g34 Back-up generator system control and monitoring presentation 8g3Annex A (normative): Summary of mandatory monitoring / supervision information and functions 11g3Annex B (normative): Man

10、datory XML structure and elements 13g3B.1 Structure of a XML document related to a diesel back-up generator system . 13g3B.2 The specific elements of a diesel back-up generator system 15g3Annex C (informative): Summary of non-mandatory monitoring / supervision information and functions 16g3History 1

11、8g3ETSI ETSI ES 202 336-5 V1.1.1 (2010-04)4Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found

12、 in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the

13、 ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Fore

14、word This ETSI Standard (ES) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 5 of a multi-part deliverable covering Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Teleco

15、mmunication Networks), as identified below: Part 1: “Generic Interface“; Part 2: “DC power system control and monitoring information model“; Part 3: “AC UPS power system control and monitoring information model“; Part 4: “AC distribution power system control and monitoring information model“; Part 5

16、: “AC diesel back-up generator system control and monitoring information model“; Part 6: “Air conditioning system control and monitoring information model“; Part 7: “Other utilities system control and monitoring information model“; Part 8: “Remote Power Feeding System control and monitoring informat

17、ion model“. ETSI ETSI ES 202 336-5 V1.1.1 (2010-04)51 Scope The present document applies to monitoring and control of AC diesel back-up generator system for telecommunication equipment. The document defines: The monitored and controlled back-up generator system architectures. The minimum set of exch

18、anged information required at the interface, described in “natural language“ in text tables. The XML tags and variables corresponding to the data in the tables. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. Fo

19、r a specific reference, subsequent revisions do not apply. Non-specific reference may be made only to a complete document or a part thereof and only in the following cases: - if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the refer

20、ring document; - for informative references. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee th

21、eir long term validity. 2.1 Normative references The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendment

22、s) applies. 1 ETSI ES 202 336-1: “Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks) Part 1: Generic Interface“. 2 ETSI ES 202 336-2: “Environmental Engineering (EE); Monit

23、oring and control interface for infrastructure equipment (Power, Cooling and environment systems used in telecommunication networks); Part 2: DC power system control and monitoring information model“. 3 ETSI EN 300 132-2: “Environmental Engineering (EE); Power supply interface at the input to teleco

24、mmunications equipment; Part 2: Operated by direct current (dc)“. 4 ETSI EN 300 132-3: “Environmental Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 3: Operated by rectified current source, alternating current source or direct current source up to 400 V“.

25、 5 ISO/IEC 10164: “Information technology - Open Systems Interconnection - Systems Management“. ETSI ETSI ES 202 336-5 V1.1.1 (2010-04)66 ISO/IEC 8879: “Information processing - Text and office systems - Standard Generalized Markup Language (SGML)“. 2.2 Informative references The following reference

26、d documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies. i.1 ETSI TR 102 336: “Environmental Engineering (EE); Pow

27、er and cooling system control and monitoring guidance“. i.2 ETSI TR 102 121: “Environmental Engineering (EE); Guidance for power distribution to telecommunication and datacom equipment“. i.3 IEEE 802.1 to 11: “LAN/MAN Standards“. i.4 ETSI ES 202 336-4: “Environmental Engineering (EE); Monitoring and

28、 Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks); Part 4: AC distribution power system control and monitoring information model“. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present docume

29、nt, the following terms and definitions apply: NOTE: Terms referring to energy interface, equipment and distribution are described in power distribution standards EN 300 132-2 3 for 48 Vdc and EN 300 132-3 4 for ac and dc lower than 400 V. alarm: any information signalling abnormal state, i.e. diffe

30、rent to specified normal state of hardware, software, environment condition (temperature, humidity, etc.) NOTE: The alarm signal should be understood by itself by an operator and should always have at least one severity qualification or codification (colour, level, etc.). EXAMPLE: Rectifier failure,

31、 battery low voltage, etc. alarm loop: electrical loop which open or closed state correspond to alarm start (set) or end (clear) state alarm message: text parts of the alarm structure alarm structure: organized set of information fields in an alarm data frame (time stamp, set/clear, text, etc.) clie

32、nt post: any device (laptop, PDA, console, etc.) connected to servers via the operation system networks to perform maintenance or supervision operations Control form Style Sheet (CSS): simple mechanism for adding style (e.g. fonts, colours, spacing) to Web documents NOTE: Tutorials, books, mailing l

33、ists for users, etc. Control Unit (CU): integrated unit in an equipment to monitor and control this equipment through sensors and actuators Data Gathering Unit (DGU): functional unit used for several functions: collect serial, digital, and analog data from several equipment; option to send (output)

34、serial or digital commands; forward/receive information to/from the Local/Remote Management Application via agreed protocols; ETSI ETSI ES 202 336-5 V1.1.1 (2010-04)7 mediation between interfaces and protocols. NOTE: This function may be integrated as part of specific equipment. Dynamic Host Control

35、 Protocol (DHCP): protocol used for self configuration of TCP/IP parameters of a workstation assigning IP address and a subnetwork mask NOTE: DHCP may also configure DNS. Dynamic Name Server (DNS): associates a single domain name to an IP address dynamic synoptic: dynamic display of geographical map

36、s, networks, installations and equipment ethernet: LAN protocol NOTE: Equivalent to IEEE 802.1 to 11 i.3. event: any information signalling a change of state which is not an alarm: e.g. battery test, change of state of battery charge NOTE: The event signal should be understood by itself by an operat

37、or and should always have at least one severity qualification or codification (colour, level, etc.). It should be transmitted in a formatted structure with text message and other fields like for alarm, e.g. an event can be coded as an alarm with severity “0“. infrastructure equipment: power, cooling

38、 and building environment systems used in telecommunications centres and Access Networks locations EXAMPLE: Cabinets, shelters, underground locations, etc. intranet: internal company network generally using Ethernet protocol and extended IP addresses logbook: chronological file that contains alarm a

39、nd event messages may be paper or electronic Management Information Base (MIB): dynamic data base that gathers all objects and should evolve to include automatic and manual configuration tools with self coherence tests menu: list of possible input command choices that may be presented in different w

40、ays on a display NOTE: Selection is normally made by a keyboard, a pointing device, a mouse or directly by finger on a sensitive screen. object: class description of items that accept a set of properties or functions NOTE: Generic objects can include more specific items and inherit from their proper

41、ties. If correctly structured, object programming can allow the system to evolve, i.e. be more future-proof. The code should intrinsically be open and structured. PHP: powerful tool for making dynamic and interactive Web pages pop-up: information or command screen that appears when a menu choice is

42、selected EXAMPLE: This may be a pop-up menu when the pointer is on a title button. REpresentational State Transfer (REST): way to build an application for distributed system as www Simple Object Access Protocol (SOAP): way to communicate between applications running on different operating systems, w

43、ith different technologies and programming languages NOTE: SOAP communicates over HTTP, because HTTP is supported by all Internet browsers and servers, SOAP traffic is not blocked by firewalls and proxy servers (see W3C). Systems Management Function (SMF): object properties or classes with projectio

44、n on CMIS application context communication NOTE: Set of ISO system management functions according to ISO/IEC 10164 5. warning: low severity alarm ETSI ETSI ES 202 336-5 V1.1.1 (2010-04)8Web: common name for the Internet or Intranet Windows: virtual area on the display that corresponds to a specific

45、 application World Wide Web Consortium (W3C): consortium founded in October 1994 to develop common interoperable protocols and promote World Wide Web NOTE: See http:/www.w3c.org. XCU: CU enabled to communicate using XML interface as defined in the present document XHTML: stricter and cleaner version

46、 of HTML. XHTML consists of all the elements in HTML 4.01 combined with the syntax of XML. It can be read by all XML browser (see W3C) eXtensible Mark-up Language (XML): application profile or restricted form of SGML NOTE: By construction, XML documents are conforming SGML the Standard Generalized M

47、arkup Language (ISO/IEC 8879 6). documents.XML is designed to describe data and focus on what data is. XML must be discerned from the well known Hypertext Transfer Mark-up Language (HTML) which was designed to display data and to focus on how data looks. XML Schema Definition (XSD): new more detaile

48、d XML description compared to the previous one, the DTD Extensible Style sheet Language (XSL): language for expressing style sheets NOTE: It consists of two parts, a language for transforming XML documents, and an XML vocabulary for specifying formatting semantics. An XSL style sheet specifies the p

49、resentation of a class of XML documents by describing how an instance of the class is transformed into an XML document that uses the formatting vocabulary. 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: AC Alternating Current CU Control Unit of an equipment DGU Data Gathering Unit HTML Hypertex Transfer Make-up Language HTTP Hypertex Transfer Protocol IP Internet Protocol LAN Local Array Network MTTR Mean Time To Repair PLC Programmable Logic Controller RMA Remote Management Ap