ETSI GS OEU 005-2018 Operational energy Efficiency for Users (OEU) Data Management for Global KPI of ICT Site Energy Management (V1 1 1).pdf

上传人:deputyduring120 文档编号:733412 上传时间:2019-01-08 格式:PDF 页数:13 大小:189.64KB
下载 相关 举报
ETSI GS OEU 005-2018 Operational energy Efficiency for Users (OEU) Data Management for Global KPI of ICT Site Energy Management (V1 1 1).pdf_第1页
第1页 / 共13页
ETSI GS OEU 005-2018 Operational energy Efficiency for Users (OEU) Data Management for Global KPI of ICT Site Energy Management (V1 1 1).pdf_第2页
第2页 / 共13页
ETSI GS OEU 005-2018 Operational energy Efficiency for Users (OEU) Data Management for Global KPI of ICT Site Energy Management (V1 1 1).pdf_第3页
第3页 / 共13页
ETSI GS OEU 005-2018 Operational energy Efficiency for Users (OEU) Data Management for Global KPI of ICT Site Energy Management (V1 1 1).pdf_第4页
第4页 / 共13页
ETSI GS OEU 005-2018 Operational energy Efficiency for Users (OEU) Data Management for Global KPI of ICT Site Energy Management (V1 1 1).pdf_第5页
第5页 / 共13页
点击查看更多>>
资源描述

1、 ETSI GS OEU 005 V1.1.1 (2018-07) Operational energy Efficiency for Users (OEU); Data Management for Global KPI of ICT Site Energy Management Disclaimer The present document has been produced and approved by the Operational energy Efficiency for Users (OEU) ETSI Industry Specification Group (ISG) an

2、d represents the views of those members who participated in this ISG. It does not necessarily represent the views of the entire ETSI membership. GROUP SPECIFICATION ETSI ETSI GS OEU 005 V1.1.1 (2018-07)2 Reference DGS/OEU-005 Keywords energy efficiency, user ETSI 650 Route des Lucioles F-06921 Sophi

3、a Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present document can be downloaded from: http:/www.etsi.org/standards-search The pre

4、sent document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such vers

5、ions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the c

6、urrent status of this and other ETSI documents is available at https:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in the present document, please send your comment to one of the following services: https:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No

7、 part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be modified without the written authorization of ETSI. The copyright and the fo

8、regoing restriction extend to reproduction in all media. ETSI 2018. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are trademarks of ETSI registered for the benefit of its Members. 3GPPTM and LTETMare trademarks of ETSI registered for the benefit of its Members and of the 3GPP Org

9、anizational Partners. oneM2M logo is protected for the benefit of its Members. GSMand the GSM logo are trademarks registered and owned by the GSM Association. ETSI ETSI GS OEU 005 V1.1.1 (2018-07)3 Contents Intellectual Property Rights 4g3Foreword . 4g3Modal verbs terminology 4g3Introduction 4g31 Sc

10、ope 5g32 References 5g32.1 Normative references . 5g32.2 Informative references 5g33 Definitions, symbols and abbreviations . 6g33.1 Definitions 6g33.2 Symbols 6g33.3 Abbreviations . 6g34 Energy management of ICT site . 6g34.1 Generalities. 6g34.2 Site information 6g34.3 Energy consumption stats . 6

11、g34.4 Site reports 7g35 Site information 7g35.1 Generalities. 7g35.2 Site information inputs . 7g35.2.1 Location 7g35.2.2 Built age 7g35.2.3 Area 7g35.2.4 Tier Class 7g35.2.5 Label . 8g35.2.6 Assessment intermediary 8g35.3 Capacity information 8g35.3.1 DC Power capacity . 8g35.3.2 Cooling capacity .

12、 8g35.3.3 IT power capacity . 8g36 Energy management stats . 8g36.1 Generalities. 8g37 Site reports 9g37.1 Generalities. 9g37.2 Mandatory Site Report inputs . 10g37.2.1 Year of data record . 10g37.2.2 ECDC. 10g37.2.3 ECSP10g37.2.4 ECREN10g37.2.5 ECREUSE. 10g37.2.6 ECTH10g37.2.7 ECHE10g37.3 Annual re

13、port summary 10g3Annex A (informative): Optional report inputs . 12g3History 13g3ETSI ETSI GS OEU 005 V1.1.1 (2018-07)4 Intellectual Property Rights Essential patents IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The information pertaining to these

14、 essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest u

15、pdates are available on the ETSI Web server (https:/ipr.etsi.org/). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web s

16、erver) which are, or may be, or may become, essential to the present document. Trademarks The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners. ETSI claims no ownership of these except for any which are indicated as being the property of

17、ETSI, and conveys no right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks. Foreword This Group Specification (GS) has been produ

18、ced by ETSI Industry Specification Group (ISG) Operational energy Efficiency for Users (OEU). Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of th

19、e ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. Introduction The objective of the present document is to enable the aggregation of study cases and examples of the implementation of

20、ETSI EN 305 200-3-1 1. ETSI ETSI GS OEU 005 V1.1.1 (2018-07)5 1 Scope The present document defines a general process to monitor the energy performance of ICT sites in accordance with ETSI EN 305 200-3-1 1. The present document: specifies required data to register the ICT site (data centre or any oth

21、er ICT site) within the data aggregation and monitoring system; defines the format for data submission to allow the information for a particular ICT site to be aggregated and monitored; describes a tool to calculate the Global KPI for Energy Management (KPIDCEM) as specified in ETSI EN 305 200-3-1 1

22、. 2 References 2.1 Normative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (inc

23、luding any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at https:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long te

24、rm validity. The following referenced documents are necessary for the application of the present document. 1 ETSI EN 305 200-3-1: “Access, Terminals, Transmission and Multiplexing (ATTM); Energy management; Operational infrastructures; Global KPIs; Part 3: ICT Sites; Sub-part 1: DCEM“. 2.2 Informati

25、ve references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) app

26、lies. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subjec

27、t area. Not applicable ETSI ETSI GS OEU 005 V1.1.1 (2018-07)6 3 Definitions, symbols and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in ETSI EN 305 200-3-1 1 and the following apply: year of data record: year of a data collection period sta

28、rted 3.2 Symbols For the purposes of the present document, the symbols given in ETSI EN 305 200-3-1 1 and the following apply: ECDC Energy Consumption DataCentre ECFENEnergy Consumption Fossil Energy ECRENEnergy Consumption Renewable ECREUSEEnergy Consumption Reused ECSPEnergy Consumption Specific P

29、rovider 3.3 Abbreviations For the purposes of the present document, the following abbreviations apply: DC Data Centre EER Energy Efficiency Ratio ICT Information Communication Technologies IT Information Technology KPI Key Performance Indicator 4 Energy management of ICT site 4.1 Generalities Energy

30、 management of an ICT site (data centre or any other ICT site) is done in a global screen. This global screen of ICT site energy management is subdivided in three sub-parts: Site information. Energy consumption stats. Site reports. 4.2 Site information This sub-part “Site information“ describes the

31、main technical characteristics of the site. 4.3 Energy consumption stats This sub-part “Energy consumption stats“ provides global energy consumption management statistics of the site. ETSI ETSI GS OEU 005 V1.1.1 (2018-07)7 4.4 Site reports This sub-part “Site reports“ provides a general summary of y

32、early reports of the site. Recorded data are input in the “new report“ screen. 5 Site information 5.1 Generalities Registration of the site is done by description of the ICT site (data centre or any other ICT site) and its main characteristics. Recorded data are input in the first sub-part of the gl

33、obal screen. The date spaces of this first sub-part are used to input characteristic data, see figure 1. Figure 1: General site information 5.2 Site information inputs 5.2.1 Location This data space will define the location of the site. 5.2.2 Built age This data space will define the year of site bu

34、ilding. 5.2.3 Area This data space will define the surface of the site. 5.2.4 Tier Class This data space will define the Tier class of the site. ETSI ETSI GS OEU 005 V1.1.1 (2018-07)8 5.2.5 Label This data space defines the site label if there is one. 5.2.6 Assessment intermediary This data space wi

35、ll define the general use of the site. 5.3 Capacity information 5.3.1 DC Power capacity This data space defines power capacity of the site. 5.3.2 Cooling capacity This data space defines cooling capacity of the site. 5.3.3 IT power capacity This data space defines power capacity of IT equipment. 6 E

36、nergy management stats 6.1 Generalities Energy management statistics are automatically provided in the second sub-part of the global screen. This second sub-part provides yearly statistics as a global curve of reused energy, see figure 2. Figure 2: Energy management statistics ETSI ETSI GS OEU 005 V

37、1.1.1 (2018-07)9 7 Site reports 7.1 Generalities A report is made on the energetic data of the site every year. The annual data are input by opening another screen by clicking on the “new report“ button. Recorded data are input in the “new report“ screen. The date spaces of the “new report“ screen a

38、re used to input annual data, see figure 3. In the third sub-part of the main screen a table summarized the site yearly reports, see clause 7.3. Figure 3 ETSI ETSI GS OEU 005 V1.1.1 (2018-07)10 7.2 Mandatory Site Report inputs 7.2.1 Year of data record This data space defines the year of this data c

39、ollection period started. 7.2.2 ECDCThis data space defines the Total consumption by Data Centre during the collection period. 7.2.3 ECSPThis data space defines the Total energy consumption from grid electricity during the collection period. 7.2.4 ECRENThis data space defines the Total energy consum

40、ed during the collection period from local renewable energy sources. 7.2.5 ECREUSEThis data space defines the Total energy reused during the collection period at the delivery point. 7.2.6 ECTHThis data space defines the Total energy consumed during the collection period from external cold loops. 7.2

41、.7 ECHEThis data space defines the Total energy consumed during the collection period by ICT equipment. 7.3 Annual report summary In the third sub-part of the main screen a table summarized the site yearly reports as defined in figure 4. ETSI ETSI GS OEU 005 V1.1.1 (2018-07)11 Figure 4 ETSI ETSI GS

42、OEU 005 V1.1.1 (2018-07)12 Annex A (informative): Optional report inputs ECFEN This data space defines consumption of local fossil energy during collection period. EER This data space defines Energy Efficiency Ratio of external cold loop cold generator. Losses This data space defines losses in the external cold distribution loop. Density This data space will define the percentage of IT room occupation. ETSI ETSI GS OEU 005 V1.1.1 (2018-07)13 History Document history V1.1.1 July 2018 Publication