ETSI TS 103 374-2-2016 Core Network and Interoperability Testing (INT) Diameter Conformance testing for Rf Ro interface (3GPP Release 10) Part 2 Test Suite Structure (TSS) and Test.pdf

上传人:brainfellow396 文档编号:740079 上传时间:2019-01-11 格式:PDF 页数:86 大小:635.01KB
下载 相关 举报
ETSI TS 103 374-2-2016 Core Network and Interoperability Testing (INT) Diameter Conformance testing for Rf Ro interface (3GPP Release 10) Part 2 Test Suite Structure (TSS) and Test.pdf_第1页
第1页 / 共86页
ETSI TS 103 374-2-2016 Core Network and Interoperability Testing (INT) Diameter Conformance testing for Rf Ro interface (3GPP Release 10) Part 2 Test Suite Structure (TSS) and Test.pdf_第2页
第2页 / 共86页
ETSI TS 103 374-2-2016 Core Network and Interoperability Testing (INT) Diameter Conformance testing for Rf Ro interface (3GPP Release 10) Part 2 Test Suite Structure (TSS) and Test.pdf_第3页
第3页 / 共86页
ETSI TS 103 374-2-2016 Core Network and Interoperability Testing (INT) Diameter Conformance testing for Rf Ro interface (3GPP Release 10) Part 2 Test Suite Structure (TSS) and Test.pdf_第4页
第4页 / 共86页
ETSI TS 103 374-2-2016 Core Network and Interoperability Testing (INT) Diameter Conformance testing for Rf Ro interface (3GPP Release 10) Part 2 Test Suite Structure (TSS) and Test.pdf_第5页
第5页 / 共86页
点击查看更多>>
资源描述

1、 ETSI TS 103 374-2 V1.1.1 (2016-01) Core Network and Interoperability Testing (INT); Diameter Conformance testing for Rf/Ro interface; (3GPP Release 10); Part 2: Test Suite Structure (TSS) and Test Purposes (TP) TECHNICAL SPECIFICATION ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)2 Reference DTS/INT-00121

2、-2 Keywords diameter, TSS Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (https:/ipr.etsi.org/). Pursuant to the ETSI IPR Policy, no investigation, including I

3、PR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been

4、 produced by ETSI Technical Committee Core Network and Interoperability Testing (INT). The present document is part 2 of a multi-part deliverable. Full details of the entire series can be found in part 1 4. Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not“,

5、 “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. ETSI ETSI TS 103 374

6、-2 V1.1.1 (2016-01)6 1 Scope The present document provides the Test Suite Structure (TSS) and Test Purposes (TP) for the test specifications for the Diameter protocol on the Rf/Ro interfaces as specified in ETSI TS 132 260 1 and ETSI TS 132 299 2 in compliance with the relevant requirements and in a

7、ccordance with the relevant guidance given in ISO/IEC 9646-7 6 and ETSI ETS 300 406 7. 2 References 2.1 Normative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version app

8、lies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in thi

9、s clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are necessary for the application of the present document. 1 ETSI TS 132 260 (V10.14.0): “Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecom

10、munications System (UMTS); LTE; Telecommunication management; Charging management; IP Multimedia Subsystem (IMS) charging (3GPP TS 32.260 version 10.14.0 Release 10)“. 2 ETSI TS 132 299 (V10.15.0): “Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UM

11、TS); LTE; Telecommunication management; Charging management; Diameter charging applications (3GPP TS 32.299 version 10.15.0 Release 10)“. 3 ETSI TS 102 790-2: “Technical Committee for IMS Network Testing (INT); Network Integration Testing; IMS specific use of Session Initiation Protocol (SIP) and Se

12、ssion Description Protocol (SDP); Conformance Testing; Part 2: Test Suite Structure (TSS) and Test Purposes (TP)“. 4 ETSI TS 103 374-1: “Core Network and Interoperability Testing (INT); Diameter Conformance testing for Rf/Ro interface; (3GPP Release 10); Part 1: Protocol Implementation Conformance S

13、tatement (PICS)“. 5 ISO/IEC 9646-1: “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 1: General concepts“. 6 ISO/IEC 9646-7: “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 7: I

14、mplementation Conformance Statements“. 7 ETSI ETS 300 406: “Methods for testing and Specification (MTS); Protocol and profile conformance testing specifications; Standardization methodology“. 8 IETF RFC 3588: “Diameter Base Protocol“. 9 IETF RFC 4005: “Diameter Network Access Server Application“. 10

15、 IETF RFC 4006: “Diameter Credit-Control Application“. ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)7 2.2 Informative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version appli

16、es. For non-specific references, the latest version of the reference document (including any amendments) applies. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are not neces

17、sary for the application of the present document but they assist the user with regard to a particular subject area. Not applicable. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in ETSI TS 132 260 1, ETSI TS 132 299 2 and th

18、e following apply: Abstract Test Method (ATM): Refer to ISO/IEC 9646-1 5. Abstract Test Suite (ATS): Refer to ISO/IEC 9646-1 5. Implementation Under Test (IUT): Refer to ISO/IEC 9646-1 5. Test Purpose (TP): Refer to ISO/IEC 9646-1 5. 3.2 Abbreviations For the purposes of the present document, the ab

19、breviations given in ETSI TS 132 260 1, ETSI TS 132 299 2 and the following apply: CDF Charging Data Function CTF Charging Trigger Function TP Test Purpose TSS Test Suite Structure 4 Test configurations 4.1 Introduction Test purposes of the present document address the IMS functional entities that a

20、re accessible via the following standardized DIAMETER interfaces: Ro and Rf. NOTE: In a real operating network the different Diameter nodes would not connect directly to each other. The connection is usually proxied through one or more Diameter Agents. In the following test architecture figures the

21、Diameter Agent is not explicitly depicted as it is seen as a transparent message handler for conformance testing purposes. ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)8 4.2 Test configurations using Rf interface The Rf interface is located between a CTF equipment hosted by an x-CSCF or a SIP AS and the C

22、DF. Figure 1: Test configuration CF_1Rf Figure 2: Test configuration CF_1Rf1Gm Figure 3: Test configuration CF_1Rf1Gm1Mw TS or (SUT) SUT or (TS) Rf CDF CTF TS SUT Gm CTFs UE1 TS CDF Rf TS SUT Gm CTFs UE TS CDF Rf I-CSCF Mw ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)9 Figure 4: Test configuration CF_1Rf1

23、Gm1Ic Figure 5: Test configuration CF_1Rf1Isc Figure 6: Test configuration CF_2Rf1Gm1Mw TS SUT Gm CTFs UE TS CDF Rf IBCF Ic TS SUT CTFs TS CDF Rf S-CSCF Isc SUT TS TS Gm CTFs UE CDF Rf I-CSCF Mw CDF Rf ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)10 4.3 Test configurations using Ro interface The Ro interf

24、ace is located between a CTF equipment hosted by an MRFC or a SIP AS or an IMS GW and the OCF. Figure 7: Test configuration CF_1Ro Figure 8: Test configuration CF_2Ro Figure 9: Test configuration CF_1Ro1Gm1Mw TS or (SUT) SUT or (TS) Ro OCF CTF TS or (SUT) SUT or (TS) Ro OCF CTF OCF Ro TS SUT Gm CTFs

25、 UE TS OCF Ro I-CSCF Mw ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)11 Figure 10: Test configuration CF_1Ro1Gm1Ic Figure 11: Test configuration CF_1Ro1Isc Figure 12: Test configuration CF_2Ro1Gm1Mw TS SUT Gm CTFs UE TS OCF Ro IBCF Ic TS SUT CTFs TS OCF Ro S-CSCF Isc TS SUT Gm CTFs UE TS OCF Ro I-CSCF Mw

26、OCF Ro ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)12 5 Test Suite Structure (TSS) and Test Purposes (TP) 5.1 Test Suite Structure 5.1.1 TP naming convention TPs are numbered, starting at 01, within each group. Groups are organized according to the TSS. Table 1: TP identifier naming convention scheme Ide

27、ntifier: _ = Test Purpose: fixed to “TP“ Interface: RF or RO = type of IUT: CDF, OCF or CTF = group MS Message syntax TC Type of Charging EC Error Cases CH Tariff Changes RE Re-authorization FH Failure Handling FA Failover CP Credit Pooling OP Other procedures (2 Clause 6.5) = sequential number (01

28、to 99) 5.1.2 Test strategy As the base standards in ETSI TS 132 260 1 and ETSI TS 132 299 2 contain no explicit requirements for testing, the TPs were generated as a result of an analysis of the base standard and the PICS specification ETSI TS 103 374-1 4. 5.1.3 TP structure Each TP has been written

29、 in a manner which is consistent with all other TPs. The intention of this is to make the TPs more readable and checkable. A particular structure has been used which is illustrated in table 2. Table 2 should be read in conjunction with any TP, i.e. please use a TP as an example to facilitate the ful

30、l comprehension of table 2. ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)13 Table 2: Structure of a single TP TP part Text Example Header see table 6.2.3 clause 6.2.3 A.2/3 Summary Short free text description of the test objective Verify that the IUT can successfully process all mandatory AVPs in a CC-Req

31、uest received due to IP-CAN session establishment. Configuration One of the test configurations as described in clauses 4.2 and 4.3 CF_1Rf Initial condition (optional) Free text description of the condition that the IUT has reached before the test purpose applies. The IUT has received AF provisions

32、information about the AF signalling flows between UE and AF. Start point Ensure that the IUT in the see IETF RFC 3588 8 clause 5.6 Open state and/or further actions before stimulus if the action is sending/receiving see below for message structure having sent an AC-Request Stimulus , see below for m

33、essage structure on receipt of a Capabilities-Exchange-Request (see note 2) or to require PCC supervision Reaction . sends, saves, does, etc. if the action is sending see below for message structure , etc. Message structure Capabilities-Exchange-Answer, etc. (see note 2) a) containing a(n) AVP b) in

34、dicating and back to a) or b) (see note 3) Vendor-Id, etc. NOTE 1: Text in italics will not appear in TPs and text between is filled in for each TP and may differ from one TP to the next. NOTE 2: All messages are considered as “valid and compatible“ unless otherwise specified in the test purpose. Th

35、is includes the presence of all mandatory AVPs as specified in IETF RFC 3588 8 and in ETSI TS 132 299 2 clauses 6.2.2, 6.2.3, 6.4.2 and 6.4.3. NOTE 3: An AVP can be embedded into another AVP. This is expressed by indentations, e.g. if Message1 contains AVP1 and AVP2 where AVP1 has AVP3 embedded this

36、 will be expressed like this: sends/receives Message 1 containing AVP1 containing AVP3indicating . containing AVP2indicating . 5.2 Test Purposes 5.2.1 PICS references All PICS items referred to in this clause are as specified in ETSI TS 103 374-1 4 unless indicated otherwise by another numbered refe

37、rence. PICS items are only meant for test selection, therefore only PICS items with status optional or conditional are explicitly mentioned. 5.2.2 Rf interface 5.2.2.1 CDF Role 5.2.2.1.1 Test selection The IUT takes the role of the CDF; PICS A.2/1. ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)14 5.2.2.1.2

38、 Message Syntax TP_RF_CDF_MS_01 Standards Reference: Clause 6.2.3 - Table 6.2.3 and IETF RFC 4005 9, Clause 3.92 and Clause 3.103 PICS item: Summary: Verify that the IUT can successfully process all mandatory AVPs in an AC-Request received due to Charging Data Transfer. Configuration: CF_1Rf Test pu

39、rpose: Ensure that the IUT on receipt of an AC-Request containing a Session-ID AVP containing an Origin-Host AVP containing an Origin-Realm AVP containing a Destination-Realm AVP containing an Accounting-Record-Type AVP containing an Accounting-Record-Number AVP containing an Acct-Application-Id AVP

40、 indicating the value 3 sends an AC-Answer containing a Session-ID AVP containing a Result-Code AVP indicating DIAMETER_SUCCESS not containing an Experimental-Result AVP containing an Origin-Host AVP containing an Origin-Realm AVP containing an Accounting-Record-Type AVP containing an Accounting-Rec

41、ord-Number AVP containing an Acct-Application-Id AVP indicating the value 3. Comments: TP_RF_CDF_MS_02 Standards Reference: RFC 3588 8, Clause 32 and 4 PICS item: Summary: Verify that the IUT can successfully process all mandatory AVPs in an AC-Request received due to Charging Data Transfer and resp

42、onds with a valid AC-Answer message. Configuration: CF_1Rf Test purpose: Ensure that the IUT on receipt of an AC-Request containing a Session-ID AVP containing an Origin-Host AVP containing an Origin-Realm AVP containing a Destination-Realm AVP containing an Accounting-Record-Type AVP containing an

43、Accounting-Record-Number AVP containing an Acct-Application-Id AVP indicating the value 3 sends an AC-Answer containing a Diameter-Header containing a Version indicating value 1 containing a Command-Flags containing T bit indicating value 0 containing r bits indicating value 0000. Comments: ETSI ETS

44、I TS 103 374-2 V1.1.1 (2016-01)15 5.2.2.1.3 Type of Charging TP_RF_CDF_TC_01 Standards Reference: Clause 6.1.1/Steps1 to 4 - Table 6.2.2/3 PICS item: A.3/1.1 Summary: Verify that the IUT can successfully process an AC-Request Event where Event Based Charging is used. Configuration: CF_1Rf Test purpo

45、se: Ensure that the IUT on receipt of an AC-Request containing an Accounting-Record-Type AVP indicating EVENT_RECORD containing an Event-Timestamp AVP optionally containing a Service-Information AVP containing at least one Subscription-ID AVP indicating the identification of the user optionally cont

46、aining an IMS-Information AVP containing a Node-Functionality AVP indicating the value 3 optionally containing a Service-Generic-Information AVP indicating the service specific parameters optionally containing a Service-Context-Id AVP sends an AC-Answer containing a Result-Code AVP indicating DIAMET

47、ER_SUCCESS not containing an Experimental-Result AVP containing an Accounting-Record-Type AVP indicating EVENT_RECORD containing an Accounting-Record-Number AVP. Comments: TP_RF_CDF_TC_02 Standards Reference: Clause 6.1.2/Steps 2 to 4 - Table 6.2.2/3 PICS item: A.3/1.2 Summary: Verify that the IUT c

48、an successfully process an AC-Request Start where Session Based Charging is used. Configuration: CF_1Rf Test purpose: Ensure that the IUT on receipt of an AC-Request containing an Accounting-Record-Type AVP containing an Accounting-Record-Type AVP indicating START_RECORD containing an Accounting-Rec

49、ord-Number AVP containing an Event-Timestamp AVP containing a Service-Information AVP indicating the service specific parameters sends an AC-Answer containing a Result-Code AVP indicating DIAMETER_SUCCESS not containing an Experimental-Result AVP containing an Accounting-Record-Type AVP indicating START_RECORD optionally containing an Acct-Interim-Interval AVP indicating the desired intermediate charging interval. Comments: Postamble action: ACR Stop is sent. ETSI ETSI TS 103 374-2 V1.1.1 (2016-01)16 T

展开阅读全文
相关资源
猜你喜欢
  • STAS 10366 2-1987 Cords for telecommunications CORDS WITH STRANDED CONDUCTORS AND TERMINALS《电信用软线 有绞线导体和端子的索线 》.pdf STAS 10366 2-1987 Cords for telecommunications CORDS WITH STRANDED CONDUCTORS AND TERMINALS《电信用软线 有绞线导体和端子的索线 》.pdf
  • STAS 10366-1976 FLEXIBLE CORDS FOR TELECOMMUNICATIONS Cords with stranded wire conductors《电信用软线 有钢绞线导体的索线 》.pdf STAS 10366-1976 FLEXIBLE CORDS FOR TELECOMMUNICATIONS Cords with stranded wire conductors《电信用软线 有钢绞线导体的索线 》.pdf
  • STAS 10367-1976 REACH AND STRADDLE FORK LIFT TRUCKS Stability test Basic tests《前移式和插腿式叉车稳定性试验 基本测试》.pdf STAS 10367-1976 REACH AND STRADDLE FORK LIFT TRUCKS Stability test Basic tests《前移式和插腿式叉车稳定性试验 基本测试》.pdf
  • STAS 10368-1982 SOLID ELECTRICAL INSULATING MATERIALS Test methods for determining the electrolytic corrosion of metals in the presence of electrical insulating materials《测定固体电绝缘材料.pdf STAS 10368-1982 SOLID ELECTRICAL INSULATING MATERIALS Test methods for determining the electrolytic corrosion of metals in the presence of electrical insulating materials《测定固体电绝缘材料.pdf
  • STAS 10369-1975 SOLID ELECTRICAL INSULATING MATERIALS Test methods for determining the relative resistance to breakdown by surface discharges《固体电气绝缘材料 表面放电相对抗击穿性测定的试验方法 》.pdf STAS 10369-1975 SOLID ELECTRICAL INSULATING MATERIALS Test methods for determining the relative resistance to breakdown by surface discharges《固体电气绝缘材料 表面放电相对抗击穿性测定的试验方法 》.pdf
  • STAS 10370 1-1990 《应力达7.5千牛,钢筋外层为24千伏的内外绝缘层 钢筋绝缘层大小 尺寸》.pdf STAS 10370 1-1990 《应力达7.5千牛,钢筋外层为24千伏的内外绝缘层 钢筋绝缘层大小 尺寸》.pdf
  • STAS 10370 2-1990 Insulated indoor-outdoor bushings with outer metal fitting of 24 kV stress class 7 5 kN INSULATORS WITHOUT FITTINGS Dimensions《外部有金属零件的室内室外绝缘衬套,24 千伏,压力级7.5千牛,无配件.pdf STAS 10370 2-1990 Insulated indoor-outdoor bushings with outer metal fitting of 24 kV stress class 7 5 kN INSULATORS WITHOUT FITTINGS Dimensions《外部有金属零件的室内室外绝缘衬套,24 千伏,压力级7.5千牛,无配件.pdf
  • STAS 10370 3-1990 INSULATED INDOOR-OUTDOOR BUSHINGS WITH OUTER METAL FITTING OF 24 kV STRESS CLASS 7 5 kN FITTINGS Dimensions《外部有金属零件的室内室外绝缘衬套,24 千伏,压力级7 5千牛, 配件尺寸 》.pdf STAS 10370 3-1990 INSULATED INDOOR-OUTDOOR BUSHINGS WITH OUTER METAL FITTING OF 24 kV STRESS CLASS 7 5 kN FITTINGS Dimensions《外部有金属零件的室内室外绝缘衬套,24 千伏,压力级7 5千牛, 配件尺寸 》.pdf
  • STAS 10371-1980 Wood particle boards BOARDS FOR EXTERNAL USE PRESSED PERPENDICULAR TO THE FACES《木质刨花板 外用板,与表面垂直压制 》.pdf STAS 10371-1980 Wood particle boards BOARDS FOR EXTERNAL USE PRESSED PERPENDICULAR TO THE FACES《木质刨花板 外用板,与表面垂直压制 》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1