ETSI TS 105 174-1-2014 Access Terminals Transmission and Multiplexing (ATTM) Broadband Deployment and Energy Management Part 1 Overview common and generic aspects (V1 2 1)《接入 终端 传输.pdf

上传人:花仙子 文档编号:740215 上传时间:2019-01-11 格式:PDF 页数:20 大小:201.86KB
下载 相关 举报
ETSI TS 105 174-1-2014 Access Terminals Transmission and Multiplexing (ATTM) Broadband Deployment and Energy Management Part 1 Overview common and generic aspects (V1 2 1)《接入 终端 传输.pdf_第1页
第1页 / 共20页
ETSI TS 105 174-1-2014 Access Terminals Transmission and Multiplexing (ATTM) Broadband Deployment and Energy Management Part 1 Overview common and generic aspects (V1 2 1)《接入 终端 传输.pdf_第2页
第2页 / 共20页
ETSI TS 105 174-1-2014 Access Terminals Transmission and Multiplexing (ATTM) Broadband Deployment and Energy Management Part 1 Overview common and generic aspects (V1 2 1)《接入 终端 传输.pdf_第3页
第3页 / 共20页
ETSI TS 105 174-1-2014 Access Terminals Transmission and Multiplexing (ATTM) Broadband Deployment and Energy Management Part 1 Overview common and generic aspects (V1 2 1)《接入 终端 传输.pdf_第4页
第4页 / 共20页
ETSI TS 105 174-1-2014 Access Terminals Transmission and Multiplexing (ATTM) Broadband Deployment and Energy Management Part 1 Overview common and generic aspects (V1 2 1)《接入 终端 传输.pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、 ETSI TS 105 174-1 V1.2.1 (2014-09) Access, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and Energy Management; Part 1: Overview, common and generic aspects TECHNICAL SPECIFICATION ETSI ETSI TS 105 174-1 V1.2.1 (2014-09)2Reference RTS/ATTM-02028 Keywords Broadband, Energy Ef

2、ficiency ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present document can be downloaded

3、 from: http:/www.etsi.org The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived differe

4、nce in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or chang

5、e of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright

6、Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be modified without the written authorization of ETSI. The copyr

7、ight and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2014. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI re

8、gistered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI TS 105 174-1 V1.2.1 (2014-09)3Contents Intellectual Property Rights 4g3Foreword . 4g3Modal verbs terminology 4g3Introduction 5g

9、31 Scope 6g32 References 6g32.1 Normative references . 6g32.2 Informative references 7g33 Definitions and abbreviations . 8g33.1 Definitions 8g33.2 Abbreviations . 9g34 Generalities . 9g35 Broadband deployment. 10g36 Network sub-systems of broadband deployment . 10g36.1 General . 10g36.2 Network sub

10、-systems . 10g36.2.1 Data centre 10g36.2.2 Operator site 11g36.2.3 Customer premises 11g36.2.4 Primary power requirements . 11g36.3 Network sites 11g36.4 Customer premises . 12g36.5 Fixed Access networks . 13g36.5.1 Schematic 13g36.5.2 Infrastructures and technologies . 13g36.6 Mobile access network

11、s 14g37 Energy management . 14g38 Overview of the multi-part deliverable: Energy management and broadband deployment . 15g38.1 Part 1: Overview, common and generic aspects . 15g38.2 Part 2: Network sites 15g38.3 Part 3: Core networks . 16g38.4 Part 4: Access networks . 16g38.4.1 Overview 16g38.4.2 S

12、ub-part 1: Fixed access networks (excluding cable) . 17g38.4.3 Sub-part 2: Mobile access networks . 17g38.5 Part 5: Customer network infrastructures . 17g38.5.1 Overview 17g38.5.2 Sub-part 1: Homes (single-tenant) 17g38.5.3 Sub-part 2: Office premises (single-tenant) 17g38.5.4 Sub-part 3: Industrial

13、 premises (single-tenant) . 18g38.5.5 Sub-part 4: Multi-tenant premises (residential and commercial) 18g38.6 Part 6: Cable networks . 18g39 Future developments in the series of documents 18g3Annex A (informative): Bibliography . 19g3History 20g3ETSI ETSI TS 105 174-1 V1.2.1 (2014-09)4Intellectual Pr

14、operty Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs);

15、 Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carri

16、ed out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical

17、 Committee Access, Terminals, Transmission and Multiplexing (ATTM). The present document is part 1, of a multi-part deliverable covering efficient energy management and broadband deployment, as identified below: TS 105 174-1: “Overview, common and generic aspects“; TS 105 174-2: “Operator sites and

18、data centres“; TS 105 174-3: “Core, regional metropolitan networks“; TS 105 174-4: “Access networks“: TS 105 174-4-1: “Fixed access networks (excluding cable)“; TS 105 174-4-2: “Mobile access networks“; TS 105 174-5: “Customer network infrastructures“: TS 105 174-5-1: “Homes (single-tenant)“; TS 105

19、 174-5-2: “Office premises (single-tenant)“; TS 105 174-5-3: “Industrial premises (single-tenant)“; TS 105 174-5-4: “Multi-tenant premises (residential and commercial)“; TR 105 174-6: “Cable Access Networks“. Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not

20、“, “may“, “may not“, “need“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation.

21、 ETSI ETSI TS 105 174-1 V1.2.1 (2014-09)5Introduction The increasing interaction between the different elements of the Information Communication Technology (ICT) sector (hardware, middleware, software and services) supports the concept of convergence in which: multi-service packages can be delivered

22、 over a common infrastructure; a variety of infrastructures is able to deliver these packages; a single multi-service-package may be delivered over different infrastructures. As a result of this convergence, the development of new services, applications and content has resulted in an increased deman

23、d for bandwidth, reliability, quality and performance, with a consequent increase in the demand for power which has implications for cost and, in some cases, availability. It is therefore important to optimize the energy management (including energy efficiency) of all network elements necessary to d

24、eliver the required services. New technologies and infrastructure strategies are expected to enable operators to decrease the energy consumption, for a given level of service, of their existing and future infrastructures thus decreasing their costs. This requires a common understanding among market

25、participants that only standards can produce. The present document is part 1 of a multi-part deliverable which has been produced by ETSI Technical Committees Access, Terminals, Transmission and Multiplexing (ATTM) and Cable in close collaboration with CENELEC via the Co-ordination Group on Installat

26、ions and Cabling (CGIC). It offers a contribution to the required standardization process by establishing an initial basis for work on ICT networks and transmission engineering, with active collaboration from a number of other ETSI and CENELEC Technical Bodies. When complete, the multi-part delivera

27、ble will contain information that has been jointly evolved to present developments in installations and transmission implementation, and describing their contribution to energy management in next generation networks (NGN). It is intended that all the documents mentioned in the foreword and more full

28、y described in clause 8 will be produced as soon as the workload allows. The multi-part deliverable will contain a high level analysis of broadband deployment and multi-service implementation, explaining the various optical fibre access network infrastructure architectures (FTTx) required to deliver

29、 efficient broadband services to customer premises and the associated difficulties, for example, the impact on implementation created by legislation and regulation of the operator environment. ETSI ETSI TS 105 174-1 V1.2.1 (2014-09)61 Scope The present document gives an overview of this multi-part d

30、eliverable covering energy management and broadband deployment. Clause 2 and clause 3 contain references, definitions and abbreviations which relate to this part; similar information will be included in the corresponding clauses of the other parts, thus ensuring that each document can be used on a “

31、stand-alone“ basis. Clause 6 describes the network sub-systems applicable to broadband deployment and their interconnections. Clause 7 considers the measures which may be taken to optimize energy management of the end-to-end network and introduces the concept of key performance indicators (KPI) to e

32、nable consistent monitoring of energy management for each of the network sub-systems described in clause 5. Clause 8 contains details of the subsequent parts and sub-parts of this multi-part deliverable which, for each of the network sub-systems described in clause 5: identify the standardization bo

33、dies working on the design and installation of the cabling within and between the network sub-systems and the relevant interfaces; provide a more strategic analysis of energy consumption trends, in a range of different broadband deployment scenarios; outline further work needed to ensure the improve

34、ment of energy efficiency in communication networks. This will enable the proper implementation of services, applications and content using an energy efficient infrastructure, though it is not the goal of this multi-part deliverable to provide detailed standardized solutions for the power distributi

35、on systems or physical design of data centres. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the refe

36、rence document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guara

37、ntee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. 1 Void. 2 CENELEC EN 50173-2: “Information technology - Generic cabling systems - Part 2: Office premises“. 3 CENELEC EN 50173-3: “Information technol

38、ogy - Generic cabling systems - Part 3: Industrial premises“. 4 CENELEC EN 50173-4: “Information technology - Generic cabling systems - Part 4: Homes“. 5 CENELEC EN 50173-5: “Information technology - Generic cabling systems - Part 5: Data centres“. 6 CENELEC TR 50173-99-2: “Information technology -

39、Implementation of BCT applications using cabling in accordance with EN 50173-4“. ETSI ETSI TS 105 174-1 V1.2.1 (2014-09)77 CENELEC EN 50174-1: “Information technology - Cabling installation - Part 1: Installation specification and quality assurance“. 8 CENELEC EN 50174-2: “Information technology - C

40、abling installation - Part 2: Installation planning and practices inside buildings“. 9 CENELEC EN 50174-3: “Information technology - Cabling installation - Part 3: Installation planning and practices outside buildings“. 10 CENELEC EN 60728 series: “Cable networks for television signals, sound signal

41、s and interactive services“. 11 Void. 12 Void. 13 Recommendation ITU-T I.113: “Vocabulary of terms for broadband aspects of ISDN“. 14 CENELEC EN 50600 series: “Information technology - Data centre facilities and infrastructures“. 15 ETSI ES 205 200-1: “Access, Terminals, Transmission and Multiplexin

42、g (ATTM); Energy management; Global KPIs; Operational infrastructures; Part 1: General requirements“. 16 ETSI ES 205 200-2-1: “Access, Terminals, Transmission and Multiplexing (ATTM); Energy management; Global KPIs; Operational infrastructures; Part 2: Specific requirements; Sub-part 1: Data centres

43、“.17 ETSI GS OEU 001: “Operational energy Efficiency for Users (OEU); Technical Global KPIs for Data Centres“. 18 ETSI GS OEU 008: “Operational energy Efficiency for Users (OEU); Global KPI for Information and Communication Technology Nodes“. 2.2 Informative references The following referenced docum

44、ents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. i.1 Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual reco

45、gnition of their conformity (R Network Termination (NT) in Next Generation Network architectures“. i.4 ETSI EG 201 730 (all parts): “Terminals access to Public Telecommunications Networks; Application of the Directive 1999/5/EC (R Guidelines for the publication of interface specifications“. i.5 ETSI

46、 EG 202 306: “Transmission and Multiplexing (TM); Access networks for residential customers“. i.6 ETSI TS 105 174-2: “Access, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and Energy Management; Part 2: Operator sites and data centres“. i.7 Void. i.8 ETSI TS 105 174-3: “Acces

47、s, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and Energy Management; Part 3: Core, regional metropolitan networks“. ETSI ETSI TS 105 174-1 V1.2.1 (2014-09)8i.9 ETSI TS 105 174-4-1: “Access, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and Energy Ma

48、nagement; Part 4: Access Networks; Sub-part 1: Fixed access networks (excluding cable)“. i.10 ETSI TS 105 174-4-2: “Access, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and Energy Management; Part 4: Access Networks; Sub-part 2: Mobile access networks“. i.11 ETSI TS 105 174-

49、5-1: “Access, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and Energy Management; Part 5: Customer network infrastructures; Sub-part 1: Homes (single-tenant)“. i.12 ETSI TS 105 174-5-2: “Access, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and Energy Management; Part 5: Customer network infrastructures; Sub-part 2: Office premises (single-tenant)“. i.13 ETSI TS 105 174-5-3: “Access, Terminals, Transmission and Multiplexing (ATTM); Broadband Deployment and E

展开阅读全文
相关资源
猜你喜欢
  • BS ISO 4250-2-2017 Earth-mover tyres and rims Loads and inflation pressures《土方机械轮胎和轮辋 载重和充气压力》.pdf BS ISO 4250-2-2017 Earth-mover tyres and rims Loads and inflation pressures《土方机械轮胎和轮辋 载重和充气压力》.pdf
  • BS ISO 4250-3-2011 Earth-mover tyres and rims Rims《运土机轮胎和轮辋 轮辋》.pdf BS ISO 4250-3-2011 Earth-mover tyres and rims Rims《运土机轮胎和轮辋 轮辋》.pdf
  • BS ISO 4251-1-2017 Tyres (ply rating marked series) and rims for agricultural tractors and machines Tyre designation and dimensions and approved rim contours《农业拖拉机和机械用轮胎(层级标志系列)和轮辋.pdf BS ISO 4251-1-2017 Tyres (ply rating marked series) and rims for agricultural tractors and machines Tyre designation and dimensions and approved rim contours《农业拖拉机和机械用轮胎(层级标志系列)和轮辋.pdf
  • BS ISO 4251-2-2017 Tyres (ply rating marked series) and rims for agricultural tractors and machines Tyre load ratings《农业拖拉机和机械用轮胎(层级标记系列)和轮辋 轮胎额定载荷值》.pdf BS ISO 4251-2-2017 Tyres (ply rating marked series) and rims for agricultural tractors and machines Tyre load ratings《农业拖拉机和机械用轮胎(层级标记系列)和轮辋 轮胎额定载荷值》.pdf
  • BS ISO 4251-4-2010 Tyres (ply rating marked series) and rims for agricultural tractors and machines - Tyre classification and nomenclature《农业拖拉机和机械用轮胎(层级标志系列)和轮缘 轮胎分类和命名》.pdf BS ISO 4251-4-2010 Tyres (ply rating marked series) and rims for agricultural tractors and machines - Tyre classification and nomenclature《农业拖拉机和机械用轮胎(层级标志系列)和轮缘 轮胎分类和命名》.pdf
  • BS ISO 4252-2007 Agricultural tractors - Operator-s workplace access and exit - Dimensions《农业拖拉机 操作员工作位置、入口和出口 尺寸》.pdf BS ISO 4252-2007 Agricultural tractors - Operator-s workplace access and exit - Dimensions《农业拖拉机 操作员工作位置、入口和出口 尺寸》.pdf
  • BS ISO 4254-13-2012 Agricultural machinery Safety Large rotary mowers《农用机械 安全 大型旋转式割草机》.pdf BS ISO 4254-13-2012 Agricultural machinery Safety Large rotary mowers《农用机械 安全 大型旋转式割草机》.pdf
  • BS ISO 4261-2013 Petroleum products Fuels (class F) Specifications of gas turbine fuels for industrial and marine applications《石油产品 燃料(F类) 工业和海洋应用燃气涡轮燃料规范》.pdf BS ISO 4261-2013 Petroleum products Fuels (class F) Specifications of gas turbine fuels for industrial and marine applications《石油产品 燃料(F类) 工业和海洋应用燃气涡轮燃料规范》.pdf
  • BS ISO 4266-1-2002 Petroleum and liquid petroleum products - Measurement of level and temperature in storage tanks by automatic methods - Measurement of level in atmospheric tanks《.pdf BS ISO 4266-1-2002 Petroleum and liquid petroleum products - Measurement of level and temperature in storage tanks by automatic methods - Measurement of level in atmospheric tanks《.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1