FORD ESF-M1L37-A-2005 COPPER WIRE BATTERY GROUND CABLE - #6 GAGE TO BE USED WITH FORD WSS-M99P1111-A 《电池接地电缆用铜丝》.pdf

上传人:visitstep340 文档编号:746117 上传时间:2019-01-14 格式:PDF 页数:1 大小:59.21KB
下载 相关 举报
FORD ESF-M1L37-A-2005 COPPER WIRE BATTERY GROUND CABLE - #6 GAGE  TO BE USED WITH FORD WSS-M99P1111-A  《电池接地电缆用铜丝》.pdf_第1页
第1页 / 共1页
亲,该文档总共1页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2005 02 16 Revised Inserted 3.0; Deleted 3.7, 3.8, 3.9, 3.10, 3.11, 4 1991 01 31 Revised DE00 E 00107002086 Revised 3.4, 3.5; std para added J. Huebner 1963 08 16 Released CTS4-58846-1 Printed copies are uncontrolled Copyright 2005, Ford Globa

2、l Technologies, LLC Page 1 of 1 COPPER WIRE, BATTERY GROUND CABLE - #6 GAGE ESF-M1L37-A 1. SCOPE The material defined by this specification is a #6 gage stranded, insulated battery ground cable. 2. APPLICATION This specification was released originally for material used as a battery ground on automo

3、tive passenger vehicles. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 INSULATION COLOR Black, unless otherwise specified on engineering drawin

4、g 3.2 CABLE QUALITY The cable shall meet all of the requirements listed herein and must be equal to the original approved sample. 3.3 WIRE QUALITY Shall consist of bare ESF-M2L1-A, soft or annealed round copper wire, prior to bunching or stranding. 3.4 CABLE CONSTRUCTION Shall consist of a minimum o

5、f 48 strands (any manufacturing tolerance must be additive) of #23 gage bare round copper wire, having a minimum area of 11.85 mm2. The strands shall be bunched and laterally served with 25 x 0.08 mm paper or polyester film insulated tape. 3.5 INSULATION QUALITY The finished cable diameter shall be

6、6.99 to 7.29 mm when covered with black elastomer meeting SAE type SGR requirements. 3.6 PHYSICAL REQUIREMENTS The finished cable shall have a maximum resistance of 1453 microohms/m and the assemblies shall conform to the following. 3.6.1 Pull Test, min 1330 N The purchased cable assemblies with terminals shall withstand a pull test, terminal to terminal.