FORD FLTM BB 101-14-2000 INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE《汽车电缆在高温条件下的绝缘层抗压试验》.pdf

上传人:brainfellow396 文档编号:746890 上传时间:2019-01-14 格式:PDF 页数:5 大小:51.48KB
下载 相关 举报
FORD FLTM BB 101-14-2000 INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE《汽车电缆在高温条件下的绝缘层抗压试验》.pdf_第1页
第1页 / 共5页
FORD FLTM BB 101-14-2000 INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE《汽车电缆在高温条件下的绝缘层抗压试验》.pdf_第2页
第2页 / 共5页
FORD FLTM BB 101-14-2000 INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE《汽车电缆在高温条件下的绝缘层抗压试验》.pdf_第3页
第3页 / 共5页
FORD FLTM BB 101-14-2000 INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE《汽车电缆在高温条件下的绝缘层抗压试验》.pdf_第4页
第4页 / 共5页
FORD FLTM BB 101-14-2000 INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE《汽车电缆在高温条件下的绝缘层抗压试验》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHOD BB 101-14 Date Action Revisions 2000 08 07 Editorial no technical change A. Cockman 1995 08 30 Printed copies are uncontrolled Page 1 of 5 Copyright 2000, Ford Global Technologies, Inc. INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE Applic

2、ation This method is used to determine the capability of automotive cable to resist pinching or compression at high temperature. This method is applicable to both stan dard and thin wall insulation cable. Apparatus Required Temperature Cabinet Capable of maintaining 250 +/ - 5 C with forced ventilat

3、ion Test Apparatus - see Figure 1 Optical Measuring Device Accurate to at least 0.01 mm Weights Appropriate for requir ements as specified in Table 1 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/ - 2 C and 50 +

4、/ - 5 % relative humidity for not less than 24 h prior to testing and tes ted under the same conditions unless otherwise specified. Procedure 1. Prepare test specimen as required by the relevant Engineering Materials Specification. 2. For thin wall insulation, install specimen cable into test appara

5、tus, as shown in Figure 1. Load it with weight as specified in Table 2 and leave it for 4 h at the temperature specified in the Engineering Materials Specification in a temperature cabinet. 3. For standard wall insulation, install specimen cable into test apparatus, as shown in F igure 1. Load it wi

6、th weight as specified in Table 1 and leave it for 4 h at the temperature specified in the Engineering Materials Specification in a temperature cabinet. FORD LABORATORY TEST METHOD BB 101-14 Page 2 of 5 Copyright 2000, Ford Global Technologies, Inc. 4. Remove specimen and cool down within 10 s by su

7、bmerging in cold water at 15 +/ - 2 C. 5. Carefully remove the conductor without deformation of the insulation. Section the test specimen along the center line shown in Figure 2 perpendicular to the axis of the specimen. 6. Measure the minimum thickness of the compressed insulation (s ee Figure 2),

8、using an optical measuring device. 7. Compare the measured thickness with the values specified in Table 1 or 2 as applicable and report. Chemicals, materials, parts, and equipment referenced in this document must be used and handled proper ly. Each party is responsible for determining proper use and

9、 handling in its facilities. FORD LABORATORY TEST METHOD BB 101-14 Page 3 of 5 Copyright 2000, Ford Global Technologies, Inc. INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE Table 1 Standard Wall Nominal Cross Section (mm sq) Compressed Weight (N) Insu lation Thick min

10、. (mm) .35 - - .50 125 0.30 .75 130 0.30 1.0 140 0.30 1.5 145 0.30 2.0 170 0.35 2.5 175 0.35 3.0 180 0.35 4.0 205 0.40 5.0 210 0.40 6.0 220 0.40 10.0 280 0.50 16.0 320 0.50 FORD LABORATORY TEST METHOD BB 101-14 Page 4 of 5 Copyright 2000, Ford Global Technologies, Inc. INSULATION COMPRESSION TEST OF

11、 AUTOMOTIVE ELECT RICAL CABLE AT HIGH TEMPERATURE Table 2 Thin Wall Nominal Cross Section (mm 2 ) Weight (PVC/TPE (N) Weight PTFE/PFA (N) Insulation Wall - Thickness Min (mm) 0.35 0.69 - 0.09 0.50 0.74 0.60 0.15 0.75 0.87 0.70 0.15 1.0 0.93 0.70 0.15 1.5 0.98 0.80 0.15 2.0 1.04 0.90 0.15 2.5 1.15 1.00 0.18 3.0 1.37 1.25 0.20 4.0 1.59 1.35 0.20 6.0 2.11 1.40 0.20 10.0 2.31 1.45 0.20 16.0 2.56 - 0.30 FORD LABORATORY TEST METHOD BB 101-14 Page 5 of 5 Copyright 2000, Ford Global Technologies, Inc. INSULATION COMPRESSION TEST OF AUTOMOTIVE ELECTRICAL CABLE AT HIGH TEMPERATURE Figure 1 Figure 2