资源描述

1、 FORD LABORATORY TEST METHOD BI 010-02 Date Action Revisions 2001 03 13 Revised Editorial No technical change A. Cockman 1992 06 17 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. MEASUREMENT OF GLOSS CHANGE OF FLAT ENAMELS AFTER POLISHING Application This

2、procedure is used to determine the increase of gloss after polishing (polish back) of low gloss or flat exterior enamels. Apparatus Required Glossmeter 60, refer FLTM BI 110-01 Polishing Block Total weight of block must be twelve pounds. (See Figure 1) Urethane Foam 4 inches x 6 inches x 1 inch thic

3、k. Felt Squares White filtering felt, 23 - 25 ounce weight per square yard, cut into 7 inch squares. Polish Rotunda R-122-A polish. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative hum

4、idity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BI 010-02 Page 2 of 3 Copyright 2001, Ford Global Technologies, Inc. Procedure 1. Determine and record gloss of panel being tested, using a 60 glossmeter. 2. App

5、ly Rotunda polish to the felt on the polishing block, so that the entire surface is coated with a thin film of polish. 3. Place felt surface on panel and polish for 10 cycles, applying force in a horizontal direction only, so that only the polishing block exerts pressure on the panel. One cycle cons

6、ists of one forward and one return stroke. 4. Determine and record gloss of polished panel, using a 60 glossmeter. 5. Report initial gloss, final gloss and gloss difference. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD BI 010-02 Page 3 of 3 Copyright 2001, Ford Global Technologies, Inc. MEASUREMENT OF GLOSS CHANGE OF FLAT ENAMELS AFTER POLISHING Figure 1