1、 FORD LABORATORY TEST METHOD BI 103-01 Date Action Revisions 2001 03 13 Revised Editorial no technical change A. Cockman 1990 05 11 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. SALT SPRAY RESISTANCE TEST FOR PAINTED PANELS AND PARTS Application This meth

2、od is used to test the resistance to salt spray of painted panels and parts. Apparatus Required Salt Spray Cabinet The salt spray cabinet and operating conditions shall meet the requirements of ASTM B 117. Scriber Carbide tipped. Source: Aircraft Specialties, Inc. G.T.S. Co. P.O. Box 98 12015 Telegr

3、aph Rd. Lapeer, MI 48446 U.S.A. Redford, MI 48239 U.S.A. (313) 664-2981 (313) 531-7666 (Model No. 90 C) (General Scriber #CM 88) Panels for this test are prepared as described in FLTM BI 103-02. Materials Required Tape No. 898 (Minnesota Mining & Manufacturing Co. - 3M) 25 mm wide. Use only the No.

4、898 tape that is made in the U.S.A. Other No. 898 tapes have different adhesion characteristics. Store in original package in a dry, dark location. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/-

5、5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BI 103-01 Page 2 of 3 Copyright 2001, Ford Global Technologies, Inc. Procedure A. Panels 1. Scribe two diagonal lines from corner to corner acros

6、s three test panels to the bare metal. Zinc-coated steel panels should be scratched through paint to zinc coating. (Do not penetrate to the bare steel). 2. Suspend the panels at an angle in the salt spray cabinet as specified in ASTM B 117 for the time designated by the material specification (testi

7、ng side up). 3. Rinse the panels with water, blot dry, and examine within 15 minutes. Measure and report in mm the maximum corrosion and blister creepage on either side of the scribed lines. Also examine panels for occurrence of surface blisters giving size and density according to ASTM D 714. In ca

8、se of zinc-coated panels, measure the maximum distance of blisters and raised paint from the scribed line. 4. Apply tape over each scribed line, in a parallel direction, using firm finger pressure to ensure contact with the panel surface (i.e., scribe line to be visible). This step is to be performe

9、d within 30 minutes after completion of Step 3. 5. Within 90 +/- 30 s of application, remove the tape by pulling back rapidly (do not jerk) at as close to an angle of 180 to the panel as possible. Evaluation Report in mm, corrosion and/or blister creep and loss of adhesion after the tape test from s

10、cribed lines and occurrence of blistering and adhesion loss beyond the scribed lines. B. Parts 1. Wash parts in water to remove dirt and contamination. 2. Suspend the parts in the salt spray cabinet in car position for the time designated by the individual specification. Parts shall not be scribed u

11、nless otherwise requested by the applicable Engineering Specifications, and the position should be varied slightly if recesses tend to collect solution. 3. Rinse the parts with warm water and a soft sponge to remove runoff stain, blot dry and examine within 15 minutes. FORD LABORATORY TEST METHOD BI

12、 103-01 Page 3 of 3 Copyright 2001, Ford Global Technologies, Inc. 4. Apply tape across the surface using firm finger pressure. This step, which is to be performed within 30 minutes after the completion of Step 3, is to help identify blistering. 5. Within 90 +/- 30 s of application, remove the tape

13、by pulling back rapidly (do not jerk) at as close to an angle of 180 to the panel as possible. Evaluation Report occurrence of blistering and corrosion. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

展开阅读全文
相关资源
猜你喜欢
  • ASTM E1801-2009 Standard Practice for Adhesive Bonding of Aluminum Facings in Foam and Beam Type Shelters《泡沫和梁型遮盖物用铝饰面板的粘结性的测定的标准实用规程》.pdf ASTM E1801-2009 Standard Practice for Adhesive Bonding of Aluminum Facings in Foam and Beam Type Shelters《泡沫和梁型遮盖物用铝饰面板的粘结性的测定的标准实用规程》.pdf
  • ASTM E1801-2015 Standard Practice for Adhesive Bonding of Aluminum Facings in Foam and Beam Type Shelters《泡沫和梁型遮盖物用铝饰面板粘结性的标准实施规程》.pdf ASTM E1801-2015 Standard Practice for Adhesive Bonding of Aluminum Facings in Foam and Beam Type Shelters《泡沫和梁型遮盖物用铝饰面板粘结性的标准实施规程》.pdf
  • ASTM E1802-2007 Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules《光电模件的隔湿完整性测试用标准试验方法》.pdf ASTM E1802-2007 Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules《光电模件的隔湿完整性测试用标准试验方法》.pdf
  • ASTM E1802-2012 Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules《光电模件的隔湿完整性试验的标准试验方法》.pdf ASTM E1802-2012 Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules《光电模件的隔湿完整性试验的标准试验方法》.pdf
  • ASTM E1802-2012(2018) Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules《光伏组件湿绝缘完整性试验的标准试验方法》.pdf ASTM E1802-2012(2018) Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules《光伏组件湿绝缘完整性试验的标准试验方法》.pdf
  • ASTM E1803-2006 Standard Test Methods for Determining Structural Capacities of Insulated Panels《测定绝缘板结构容量的标准试验方法》.pdf ASTM E1803-2006 Standard Test Methods for Determining Structural Capacities of Insulated Panels《测定绝缘板结构容量的标准试验方法》.pdf
  • ASTM E1803-2014 Standard Test Methods for Determining Strength Capacities of Structural Insulated Panels《测定结构绝缘板承载力的标准试验方法》.pdf ASTM E1803-2014 Standard Test Methods for Determining Strength Capacities of Structural Insulated Panels《测定结构绝缘板承载力的标准试验方法》.pdf
  • ASTM E1804-2007 Standard Practice for Performing and Reporting Cost Analysis During the Design Phase of a Project《项目设计阶段的执行和报告成本分析用标准实施规程》.pdf ASTM E1804-2007 Standard Practice for Performing and Reporting Cost Analysis During the Design Phase of a Project《项目设计阶段的执行和报告成本分析用标准实施规程》.pdf
  • ASTM E1804-2012 Standard Practice for Performing and Reporting Cost Analysis During the Design Phase of a Project 《项目设计阶段的执行和成本分析报告的标准操作规程》.pdf ASTM E1804-2012 Standard Practice for Performing and Reporting Cost Analysis During the Design Phase of a Project 《项目设计阶段的执行和成本分析报告的标准操作规程》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1