1、 FORD LABORATORY TEST METHOD BI 117-01 Date Action Revisions 2001 03 19 Revised Editorial no technical change A. Cockman 1989 04 24 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. THICKNESS MEASUREMENT OF PAINT FILMS Application This procedure details recom

2、mended practices and equipment for measurement of thickness of paint films on metallic substrates. Apparatus Required Permascope or Leptoscope, or equivalent Note: If other measuring principles are applied these must be indicated in the test report and if required coordinated with Product Engineerin

3、g. Measurement Principle Two (2) types of instruments can be used depending on whether the substrate is magnetic iron or steel, or non-magnetic metals. The instrument consists of a gauge head connected to an indicating unit. A magnetic flux is produced when the probe tips are placed in contact with

4、a paint film over a ferritic substrate. The paint film acts as an air gap in the magnetic circuit. The magnetic impedance of the gauge head varies as a function of the air gap length, i.e. the thickness of the paint film, and thickness is read directly on the scale of the recording instrument. When

5、the substrate is a non-magnetic metallic, an Eddy current system is utilized. A high frequency magnetic field is created in the probes measuring system and Eddy currents are generated when the probe is placed onto the non-magnetic substrate. Magnitude of the Eddy current depends on distance between

6、metal and probe, shape and electrical conductivity of specimen. The gauge must be standardized against base materials of the same composition, geometry, heat treatment and surface treatment (such as phosphating or galvanizing) for maximum accuracy. Note: The following factors may have an influence o

7、n the results: 1. Surface roughness and waviness of the surface. FORD LABORATORY TEST METHOD BI 117-01 Page 2 of 3 Copyright 2001, Ford Global Technologies, Inc. 2. Magnetic conditions of the substrate material. 3. Thickness of the substrate material. 4. Hardness of the coating and pressure applied

8、to gauge head during test. (A constant pressure probe should be used where feasible.) 5. Curvature of the surface (measurement should be taken parallel to the curvature axis). 6. Distance from the measuring point to an edge of the material under test. Edge effects should be avoided. 7. Deviation of

9、the magnetic probe axis from a perpendicular to the area to be measured. (The probe should be normal to the measured surface.) 8. Area of test piece, minimum 30 mm x 30 mm. 9. Some standards from instrument manufacturers are only of nominal film thickness. (see Note on Page 3) Calibration Thickness

10、standards are furnished with the instrument and are used to calibrate the gauge as follows: 1. Warm up the instrument for 20 minutes before use. 2. Select the proper scale range for the estimated coating thickness. 3. Calibrate the instrument as prescribed in the manufacturers manual. 4. For test pa

11、nels and bodies the calibration must be performed on steel body skin panels ground to a surface finish of 0.9 - 1.8 micrometers, unless otherwise specified. Calibrations in cases when either an uncoated specimen is not available or the magnetic properties of the coated and uncoated specimens are dif

12、ferent: 1. Select proper scale range (first reading). 2. Place gauge head on coating (second readings). 3. Insert suitable thickness standard between coating and gauge head. 4. If the second reading on the instrument is not equal to the original reading plus the thickness of the standard, the calibr

13、ating control should be adjusted until the instrument indicates the expected value of coating thickness plus standard. FORD LABORATORY TEST METHOD BI 117-01 Page 3 of 3 Copyright 2001, Ford Global Technologies, Inc. 5. Repeat this procedure two (2) or three (3) times to adjust the gauge correctly fo

14、r the particular base metal. Procedure Paint over Magnetic or Non-Magnetic Metal Substrates 1. Warm up the instrument for 20 minutes before use. 2. Select scale range for estimated thickness. 3. Adjust or zero gauge on an uncoated area of the base metal of the test specimen. This should be done on a

15、n area having the same contour as the test specimen and may require removal of some paint with a suitable solvent or paint remover. 4. Select a standard according to the requirements of the Instrument manufacturer and insert between the uncoated specimen and gauge head or probe and adjust indicator

16、to read the thickness of the standard. 5. Place probe on painted area of the specimen and read thickness of coating. Possible errors with Paint on Finished Bodies Measurements on areas, where due to different type of body construction, increased metal thickness exists, also edges, sharp radii, and c

17、loseness to trim moulding may not be accurate because of interaction with the flux lines of the instrument. Note: Standards and instrument correlation checks against certified coating thickness Calibration Standards for non-magnetic coatings on steel should be carried out at a minimum of six (6) mon

18、thly intervals (Source of certified standards, US Department of Commerce, Washington, D.C.). Evaluation Report type of equipment, scale range, location of measuring points, average, minimum-maximum range, and if appropriate Standard Deviation. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

展开阅读全文
相关资源
猜你喜欢
  • ETSI TS 118 123-2016 oneM2M Home Appliances Information Model and Mapping (V2 0 0 oneM2M TS-0023 version 2 0 0 Release 2)《OneM2M(物联网协议联盟) 家庭信息模型和映射(V2 0 0 oneM2M TS-0023版本2 0 0 发行版.pdf ETSI TS 118 123-2016 oneM2M Home Appliances Information Model and Mapping (V2 0 0 oneM2M TS-0023 version 2 0 0 Release 2)《OneM2M(物联网协议联盟) 家庭信息模型和映射(V2 0 0 oneM2M TS-0023版本2 0 0 发行版.pdf
  • ETSI TS 118 124-2016 oneM2M OIC Interworking (V2 0 0 oneM2M TS-0024 version 2 0 0 Release 2)《oneM2M(物联网协议联盟) OIC 网路互通(V2 0 0 oneM2M TS-0024 版本2 0 0 发行版本2)》.pdf ETSI TS 118 124-2016 oneM2M OIC Interworking (V2 0 0 oneM2M TS-0024 version 2 0 0 Release 2)《oneM2M(物联网协议联盟) OIC 网路互通(V2 0 0 oneM2M TS-0024 版本2 0 0 发行版本2)》.pdf
  • ETSI TS 118 132-2017 MAF and MEF Interface Specification (V2 0 2 oneM2M TS-0032 version 2 0 2 Release 2A).pdf ETSI TS 118 132-2017 MAF and MEF Interface Specification (V2 0 2 oneM2M TS-0032 version 2 0 2 Release 2A).pdf
  • ETSI TS 119 101-2016 Electronic Signatures and Infrastructures (ESI) Policy and security requirements for applications for signature creation and signature validation (V1 1 1)《电子签名.pdf ETSI TS 119 101-2016 Electronic Signatures and Infrastructures (ESI) Policy and security requirements for applications for signature creation and signature validation (V1 1 1)《电子签名.pdf
  • ETSI TS 119 101-2016 Electronic Signatures and Infrastructures (ESI) Policy and security requirements for applications for signature creation and signature validation (V1 1 1)《电子签名_1.pdf ETSI TS 119 101-2016 Electronic Signatures and Infrastructures (ESI) Policy and security requirements for applications for signature creation and signature validation (V1 1 1)《电子签名_1.pdf
  • ETSI TS 119 102-1-2015 Electronic Signatures and Infrastructures (ESI) Procedures for Creation and Validation of AdES Digital Signatures Part 1 Creation and Validation (V1 0 1)《电子签.pdf ETSI TS 119 102-1-2015 Electronic Signatures and Infrastructures (ESI) Procedures for Creation and Validation of AdES Digital Signatures Part 1 Creation and Validation (V1 0 1)《电子签.pdf
  • ETSI TS 119 122-1-2015 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures Part 1 Building blocks and CAdES baseline signatures (V1 0 1)《电子签名和基础设施 (ESI) CAdES数.pdf ETSI TS 119 122-1-2015 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures Part 1 Building blocks and CAdES baseline signatures (V1 0 1)《电子签名和基础设施 (ESI) CAdES数.pdf
  • ETSI TS 119 122-1-2015 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures Part 1 Building blocks and CAdES baseline signatures (V1 0 1)《电子签名和基础设施 (ESI) CAdES数_1.pdf ETSI TS 119 122-1-2015 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures Part 1 Building blocks and CAdES baseline signatures (V1 0 1)《电子签名和基础设施 (ESI) CAdES数_1.pdf
  • ETSI TS 119 122-2-2015 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures Part 2 Extended CAdES signatures (V1 0 1)《电子签名和基础设施 (ESI) CAdES数字签名 第2部分 扩展式CAdES签名 .pdf ETSI TS 119 122-2-2015 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures Part 2 Extended CAdES signatures (V1 0 1)《电子签名和基础设施 (ESI) CAdES数字签名 第2部分 扩展式CAdES签名 .pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1