资源描述

1、 FORD LABORATORY TEST METHOD BN 023-02 Date Action Revisions 2000 12 01 Revised Rev Source address & updated L. Graham 1992 07 09 Printed copies are uncontrolled Page 1 of 3 Copyright 2000, Ford Global Technologies, Inc. THICKNESS TEST FOR PADDING MATERIALS Application This procedure is used to meas

2、ure the thickness of padding materials used for seating or acoustical applications. Apparatus Required Thickness Tester The instrument required for this test is a modified thickness tester. A sketch of the instrument is attached. This is the same instrument used in FLTM BN 123-01. Source: Randen Tec

3、hnologies, Inc. R. R. #5 Strathroy, Ontario N7G 3H6 Canada Tel: 519-245-6115 Fax: 519-245-5062 Dial Indicator The dial indicator, Model #362, with .001 inch graduations. Source: B.C. Ames Co. Waltham, MA Weights 1 weight of 0.5 lb. Conditioning and Test Conditions All test values indicated herein ar

4、e based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BN 023-02 Page 2 of 3 Copyright 2000, Ford Global Technologie

5、s, Inc. Procedure 1. Balance the instrument by turning the counter weight at the rear until the upper plate is 1/2 inch from the surface of the lower plate. Care should be taken not to jar instrument severely after balancing as this will change counter weight setting. 2. Apply 1/2 lb weight to the u

6、pper platen and leave through entire test. 3. Adjust dial indicator to zero with platens in contact. 4. Place 12 by 12 inch sample of padding material over lower platen of instrument. If material appears to be of different densities, the higher density should be placed on the bottom. If material has

7、 attached sheeting or resinated surface, the sheeting or resinated surface should be placed on top. 5. Lower upper platen with weight in place onto sample. The platen should not be dropped on the material abruptly. The scale reading of the material should be made within 10 s after applying weight. R

8、eport test results as required by the material specification. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD BN 023-02 Page 3 of 3 Copyright 2000, Ford Global Technologies, Inc. THICKNESS TEST FOR PADDING MATERIALS Measure-Matic Apparatus for Thickness Test

展开阅读全文
相关资源
猜你喜欢
  • DIN EN ISO 23611-6-2013 Soil quality - Sampling of soil invertebrates - Part 6 Guidance for the design of sampling programmes with soil invertebrates (ISO 23611-6 2012) German vers.pdf DIN EN ISO 23611-6-2013 Soil quality - Sampling of soil invertebrates - Part 6 Guidance for the design of sampling programmes with soil invertebrates (ISO 23611-6 2012) German vers.pdf
  • DIN EN ISO 23631 Berichtigung 1-2007 Water quality - Determination of dalapon trichloroacetic acid and selected haloacetic acids - Method using gas chromatography (GC-ECD and or GCd.pdf DIN EN ISO 23631 Berichtigung 1-2007 Water quality - Determination of dalapon trichloroacetic acid and selected haloacetic acids - Method using gas chromatography (GC-ECD and or GCd.pdf
  • DIN EN ISO 23631-2006 Water quality - Determination of dalapon trichloroacetic acid and selected haloacetic acids - Method using gas chromatography (GC-ECD and or GC-MS detection) n.pdf DIN EN ISO 23631-2006 Water quality - Determination of dalapon trichloroacetic acid and selected haloacetic acids - Method using gas chromatography (GC-ECD and or GC-MS detection) n.pdf
  • DIN EN ISO 23640-2015 In vitro diagnostic medical devices - Evaluation of stability of in vitro diagnostic reagents (ISO 23640 2011) German version EN ISO 23640 2015《体外诊断医疗器械 体外诊断试.pdf DIN EN ISO 23640-2015 In vitro diagnostic medical devices - Evaluation of stability of in vitro diagnostic reagents (ISO 23640 2011) German version EN ISO 23640 2015《体外诊断医疗器械 体外诊断试.pdf
  • DIN EN ISO 23747-2015 Anaesthetic and respiratory equipment - Peak expiratory flow meters for the assessment of pulmonary function in spontaneously breathing humans (ISO 23747 2015.pdf DIN EN ISO 23747-2015 Anaesthetic and respiratory equipment - Peak expiratory flow meters for the assessment of pulmonary function in spontaneously breathing humans (ISO 23747 2015.pdf
  • DIN EN ISO 23753-1-2011 Soil quality - Determination of dehydrogenase activity in soil - Part 1 Method using triphenyltetrazolium chloride (TTC) (ISO 23753-1 2005) German version E.pdf DIN EN ISO 23753-1-2011 Soil quality - Determination of dehydrogenase activity in soil - Part 1 Method using triphenyltetrazolium chloride (TTC) (ISO 23753-1 2005) German version E.pdf
  • DIN EN ISO 23753-2-2011 Soil quality - Determination of dehydrogenase activity in soil - Part 2 Method using iodotetrazolium chloride (INT) (ISO 23753-2 2005) German version EN ISO.pdf DIN EN ISO 23753-2-2011 Soil quality - Determination of dehydrogenase activity in soil - Part 2 Method using iodotetrazolium chloride (INT) (ISO 23753-2 2005) German version EN ISO.pdf
  • DIN EN ISO 23771-2015 Textile machinery - Guide to the design of textile machinery for reduction of the noise emissions (ISO 23771 2015) German version EN ISO 23771 2015《纺织机械 纺织机械减.pdf DIN EN ISO 23771-2015 Textile machinery - Guide to the design of textile machinery for reduction of the noise emissions (ISO 23771 2015) German version EN ISO 23771 2015《纺织机械 纺织机械减.pdf
  • DIN EN ISO 23907-2013 Sharps injury protection - Requirements and test methods - Sharps containers (ISO 23907 2012) German version EN ISO 23907 2012《锐器损伤防护 试验方法和要求 利器盒(ISO 23907-20.pdf DIN EN ISO 23907-2013 Sharps injury protection - Requirements and test methods - Sharps containers (ISO 23907 2012) German version EN ISO 23907 2012《锐器损伤防护 试验方法和要求 利器盒(ISO 23907-20.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1