FORD FLTM BN 125-01-2015 RESISTANCE TO LINT PICKUP AND LINT RETENTION OF FABRICS.pdf

上传人:sumcourage256 文档编号:747263 上传时间:2019-01-14 格式:PDF 页数:7 大小:896.83KB
下载 相关 举报
FORD FLTM BN 125-01-2015 RESISTANCE TO LINT PICKUP AND LINT RETENTION OF FABRICS.pdf_第1页
第1页 / 共7页
FORD FLTM BN 125-01-2015 RESISTANCE TO LINT PICKUP AND LINT RETENTION OF FABRICS.pdf_第2页
第2页 / 共7页
FORD FLTM BN 125-01-2015 RESISTANCE TO LINT PICKUP AND LINT RETENTION OF FABRICS.pdf_第3页
第3页 / 共7页
FORD FLTM BN 125-01-2015 RESISTANCE TO LINT PICKUP AND LINT RETENTION OF FABRICS.pdf_第4页
第4页 / 共7页
FORD FLTM BN 125-01-2015 RESISTANCE TO LINT PICKUP AND LINT RETENTION OF FABRICS.pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、 FORD LABORATORY TEST METHOD BN 125-01 Date Action Revisions Rev. 1 2015 05 28 Revised See Summary of Revisions L. Schmalz, NA 2013 01 22 Activated Maria Dumitrescu; Mark Montgomery; Marcelo Fontes, Cheney Chen, Controlled document at www.MATS Copyright 2015, Ford Global Technologies, LLC Page 1 of

2、7 RESISTANCE TO LINT PICKUP AND LINT RETENTION OF FABRICS Application This test method determines the lint resistance and lint retention on automotive seat fabrics. This test uses a rotating platform to rub the test fabric against a reference piece of material under a fixed weight. The platform rota

3、tes on a 19 mm radius at approximately 58 revolutions per minute. Apparatus and Materials Required 1. Pilling Tester The pilling tester is described in ASTM D3511 and modified to hold the test fabric to the rotating platform. The round shaped lint cloth holder weight is 660 +/- 5 g, see Fig 1a. Sour

4、ce: Schap Specialty Machine, Inc. 17309 Taft Road Spring Lake, MI 49456 Phone (616) 846-6530 Fax: 616-846-6675 Email: 2. Vacuum cleaner, canister type, with a soft brush attachment Note: The vacuum used with the Taber test machine is acceptable when set to the highest power setting. The soft brush

5、attachment shall have approximately 45 mm long bristles. 3. Lint Cloth: Bleached Cotton style # 425. Source: Test Fabrics, Inc. PO Box 3026 415 Delaware Ave West Pittston, PA 18643 USA Phone: (570) 603 0432 Fax: (570) 603 0433 Email: or FORD LABORATORY TEST METHOD BN 125-01 Copyright 2015, Ford G

6、lobal Technologies, LLC Page 2 of 7 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwi

7、se specified. Procedure 1. Cut two fabric specimens (see Fig 2) 2. Mount the fabric specimens face up on the lower wood board of the pilling tester, see Fig 3. Tightly secure the specimens to the board to prevent wrinkling. 3. Mount the lint cloth on the round shaped holder and secure with the rubbe

8、r “O“ ring as it shows in Fig 1b. Place the holder on the station with the fabric specimen. (see Fig 4) 4. Start the machine to rub the lint cloth on the face fabric for 30 seconds. Lint cloth must be replaced after every test. 5. Remove tested specimens from the wood board. Evaluate the tested spec

9、imen lying flat on the seat of an office chair and then pin it to the seat back. Report both the horizontal and vertical ratings. Label this test specimen “lint pickup“. 6. Vacuum the second specimen using 10 strokes (one stroke is the back and forth motion) with brush attachment. Evaluate the vacuu

10、med specimen lying flat on the seat of an office chair and then pin it to the seat back. Report both the horizontal and vertical ratings. Label this test specimen “lint retention“. Evaluation Compare the tested specimens to an untested fabric. Use the photographic standards on pages 5 and 6 to rate

11、the pick up and lint retention specimens using the following scale: Rating 4 - No linting less than 5 cotton fibers left on the fabric surface Rating 3 - Slight - slight cotton fiber left on the fabric surface Rating 2 - Moderate - large amount of fiber left on the fabric surface and/or a change in

12、the fabric Appearance Rating 1 - Severe- clumps of fibers entangled with the fabric surface or complete coverage of fabric surface by fiber Report the Rating for the lint pickup specimen and lint retention specimen. Chemicals, materials, parts, and equipment referenced in this document must be used

13、and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD BN 125-01 Copyright 2015, Ford Global Technologies, LLC Page 3 of 7 Summary of Revisions 2015 05 28 -Removed from step 5 gently shake off the excess fibers and added

14、 statement on evaluating the sample flat and horizontal by pinning to an office chair - Added to step 6 statement on evaluating the vacuumed specimen on the vertical and horizontal by pinning to an office chair. -Updated rating 4 from no cotton fibers to less than 5 Fig. 1a Round shape holder for li

15、nt cloth Fig. 1b Mounted lint cloth on the round shape holder FORD LABORATORY TEST METHOD BN 125-01 Copyright 2015, Ford Global Technologies, LLC Page 4 of 7 Fig. 2 Specimen size Fig. 3 Specimens mounted on the lower wood board FORD LABORATORY TEST METHOD BN 125-01 Copyright 2015, Ford Global Techno

16、logies, LLC Page 5 of 7 Fig 4. Mounted samples ready for test FORD LABORATORY TEST METHOD BN 125-01 Copyright 2015, Ford Global Technologies, LLC Page 6 of 7 Photographic standard of Rating 4 Photographic standard of Rating 3 FORD LABORATORY TEST METHOD BN 125-01 Copyright 2015, Ford Global Technologies, LLC Page 7 of 7 Photographic standard of Rating 2 Photographic standard of Rating 1

展开阅读全文
相关资源
猜你喜欢
  • CEPT ERC REPORT 61-1998 Harmonisation of Licensing (Biel Bienne)《许可证发放统一 比尔》.pdf CEPT ERC REPORT 61-1998 Harmonisation of Licensing (Biel Bienne)《许可证发放统一 比尔》.pdf
  • CEPT ERC REPORT 62-1998 Compatibility Analysis Regarding Possible Sharing between the UIC System and Radio Microphones in the Frequency Ranges 876 - 880 MHz and 921 - 925 MHz (Siof.pdf CEPT ERC REPORT 62-1998 Compatibility Analysis Regarding Possible Sharing between the UIC System and Radio Microphones in the Frequency Ranges 876 - 880 MHz and 921 - 925 MHz (Siof.pdf
  • CEPT ERC REPORT 63-1998 Introduction of Radio Microphone Applications in the Frequency Range 1785 - 1800 MHz (Siofok)《1785-1800 MHz频率范围中引入无线电麦克风应用 西欧福克》.pdf CEPT ERC REPORT 63-1998 Introduction of Radio Microphone Applications in the Frequency Range 1785 - 1800 MHz (Siofok)《1785-1800 MHz频率范围中引入无线电麦克风应用 西欧福克》.pdf
  • CEPT ERC REPORT 64-1999 Frequency Sharing between UMTS and Existing Fixed Services (Menton May 1999)《UMTS和现有固定业务之间的频率共享 门顿1999年5月》.pdf CEPT ERC REPORT 64-1999 Frequency Sharing between UMTS and Existing Fixed Services (Menton May 1999)《UMTS和现有固定业务之间的频率共享 门顿1999年5月》.pdf
  • CEPT ERC REPORT 65-1999 Adjacent Band Compatibility between UMTS and Other Services in the 2 GHz Band (Menton May 1999 Revised in Helsinki November 1999)《2GHz频段中UMTS和其他业务之间相邻频段的兼容性.pdf CEPT ERC REPORT 65-1999 Adjacent Band Compatibility between UMTS and Other Services in the 2 GHz Band (Menton May 1999 Revised in Helsinki November 1999)《2GHz频段中UMTS和其他业务之间相邻频段的兼容性.pdf
  • CEPT ERC REPORT 66-1999 ERC Report on Inspection Procedures Including Training of Inspectors (Antalya May 1999)《ERC检查程序报告 包括检查员的培训 安塔利亚1999年5月》.pdf CEPT ERC REPORT 66-1999 ERC Report on Inspection Procedures Including Training of Inspectors (Antalya May 1999)《ERC检查程序报告 包括检查员的培训 安塔利亚1999年5月》.pdf
  • CEPT ERC REPORT 67-1999 Study of the Frequency Sharing between HIPERLANs and MSS Feeder Links in the 5 GHz Band (Marbella February 1999)《5 GHz频段中HIPERLAN和MSS馈线链路之间频率共享研究 马贝拉1999年2月.pdf CEPT ERC REPORT 67-1999 Study of the Frequency Sharing between HIPERLANs and MSS Feeder Links in the 5 GHz Band (Marbella February 1999)《5 GHz频段中HIPERLAN和MSS馈线链路之间频率共享研究 马贝拉1999年2月.pdf
  • CEPT ERC REPORT 68-2000 Monte Carlo Radio Simulation Methodology (Naples February 2000)《蒙特卡洛无线电仿真方法 那不勒斯2000年2月》.pdf CEPT ERC REPORT 68-2000 Monte Carlo Radio Simulation Methodology (Naples February 2000)《蒙特卡洛无线电仿真方法 那不勒斯2000年2月》.pdf
  • CEPT ERC REPORT 69-1999 Propagation Model and Interference Range Calculation for Inductive Systems 10 KHZ - 30 MHZ (Marbella February 1999)《10KHz-30MHz电感式系统传播模型和干扰范围计算方法 马贝拉1999年2月.pdf CEPT ERC REPORT 69-1999 Propagation Model and Interference Range Calculation for Inductive Systems 10 KHZ - 30 MHZ (Marbella February 1999)《10KHz-30MHz电感式系统传播模型和干扰范围计算方法 马贝拉1999年2月.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1