FORD FLTM BV 129-1-2000 SEALING PERFORMANCE OF FORMED-IN-PLACE ADHESIVE GASKETS.pdf

上传人:appealoxygen216 文档编号:747644 上传时间:2019-01-14 格式:PDF 页数:3 大小:37.27KB
下载 相关 举报
FORD FLTM BV 129-1-2000 SEALING PERFORMANCE OF FORMED-IN-PLACE ADHESIVE GASKETS.pdf_第1页
第1页 / 共3页
FORD FLTM BV 129-1-2000 SEALING PERFORMANCE OF FORMED-IN-PLACE ADHESIVE GASKETS.pdf_第2页
第2页 / 共3页
FORD FLTM BV 129-1-2000 SEALING PERFORMANCE OF FORMED-IN-PLACE ADHESIVE GASKETS.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHOD BV 129-01 Date Action Revisions 2000 12 11 Revised Editorial no technical change A. Cockman 1992 09 16 Printed copies are uncontrolled Page 1 of 3 Copyright 2000, Ford Global Technologies, Inc. SEALING PERFORMANCE OF FORMED-IN-PLACE ADHESIVE GASKETS Application This test

2、 method determines the sealing performance of formed-in-place gasket eliminator adhesives. It involves the use of rigid metal flanges, assembled with and without shims to create specific gaps. Materials and Apparatus Required Air Pressure or Nitrogen Source Capable of supplying 0 - 1350 kPa. Pressur

3、e Gage Torque Wrench Calibrated to 0 - 50 N-m. Abrasive Paper 220 grit aluminum oxide, wet or dry. Water Reservoir Of sufficient size to observe leakage. Test Fixture - (see Figure 1) Steel Shims - 38 mm O.D. x 11 mm I.D. Thickness as specified. Cleaning Solvent Desiccator Conditioning and Test Cond

4、itions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BV 129-01 Page 2 of

5、 3 Copyright 2000, Ford Global Technologies, Inc. Test Fixture Preparation 1. Clean the test fixture using solvent. 2. Abrade the sealing surfaces against a 220 grit aluminum oxide abrasive paper on a hard flat surface, until a uniform finish is attained. 3. Clean the abraded fixture and store in de

6、siccator (reprocess if not used within 72 h). Procedure 1. From the master adhesive sample, draw off a sufficient quantity of adhesive to perform all required performance tests. The adhesive shall be applied using a disposable pipet, an applicator stick or other suitable means that will ensure compl

7、ete coverage of the application area. To prevent contamination, material reserved for performance testing shall not be returned to the master sample for retaining purposes. 2. Secure the lower half of the test fixture in a vise. 3. Apply sufficient material to the lower flange to completely fill the

8、 pressure annulus area. Care should be taken to ensure that there are no entrapped air pockets which might result in a leak path. Excessive material should not be applied, since it will create a fillet in the pressure annulus, thereby affecting test results. 4. For various gap sizes, install the app

9、ropriate size shim onto the center of one flange after applying a small amount of sealant to each side of the shim. This prevents pressure loss through the assembly bolt hole. 5. Assemble the top half of the fixture onto the lower half, being careful to contact the material evenly. Once the top fixt

10、ure has been set in place, do not attempt to move it. 6. Torque the fixture halves together with 27 N-m of applied torque. 7. Attach the air pressure source to the fixture and gradually increase the pressure to 1350 kPa. 8. Place the fixture under water for 10 s and observe for air bubbles flow from

11、 fixture. 9. Record the result. 10. Disassemble the fixture and clean as in Test Fixture Preparation. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD BV 129-01 Page 3 of 3 Copyright 2000, Ford Global Technologies, Inc. SEALING PERFORMANCE OF FORMED-IN-PLACE ADHESIVE GASKETS

展开阅读全文
相关资源
猜你喜欢
  • EN 1710-2005 2500 Equipment and components intended for use in potentially explosive atmospheres in underground mines (Incorporates Amendment A1 2008)《地下矿井潜在爆炸性环境下使用的设备和组件 包含修改件A1-.pdf EN 1710-2005 2500 Equipment and components intended for use in potentially explosive atmospheres in underground mines (Incorporates Amendment A1 2008)《地下矿井潜在爆炸性环境下使用的设备和组件 包含修改件A1-.pdf
  • EN 1715-1-2008 en Aluminium and aluminium alloys - Drawing stock - Part 1 General requirements and technical conditions for inspection and delivery《铝和铝合金 拉拔坯料 第1部分 检验和交货的一般要求和技术条件》.pdf EN 1715-1-2008 en Aluminium and aluminium alloys - Drawing stock - Part 1 General requirements and technical conditions for inspection and delivery《铝和铝合金 拉拔坯料 第1部分 检验和交货的一般要求和技术条件》.pdf
  • EN 1715-2-2008 en Aluminium and aluminium alloys - Drawing stock - Part 2 Specific requirements for electrical applications《铝和铝合金 拉拔坯料 第2部分 电气应用的特殊要求》.pdf EN 1715-2-2008 en Aluminium and aluminium alloys - Drawing stock - Part 2 Specific requirements for electrical applications《铝和铝合金 拉拔坯料 第2部分 电气应用的特殊要求》.pdf
  • EN 1715-3-2008 en Aluminium and aluminium alloys - Drawing stock - Part 3 Specific requirements for mechanical uses (excluding welding)《铝和铝合金 拉拔坯料 第3部分 机械用途(不包括焊接)特殊要求》.pdf EN 1715-3-2008 en Aluminium and aluminium alloys - Drawing stock - Part 3 Specific requirements for mechanical uses (excluding welding)《铝和铝合金 拉拔坯料 第3部分 机械用途(不包括焊接)特殊要求》.pdf
  • EN 1715-4-2008 en Aluminium and aluminium alloys - Drawing stock - Part 4 Specific requirements for welding applications《铝和铝合金 拉拔坯料 第4部分 焊接应用的特殊要求》.pdf EN 1715-4-2008 en Aluminium and aluminium alloys - Drawing stock - Part 4 Specific requirements for welding applications《铝和铝合金 拉拔坯料 第4部分 焊接应用的特殊要求》.pdf
  • EN 1716-1997 en Plastics Piping Systems - Polyethylene (PE) Tapping Tees - Test Method for Impact Resistance of an Assembled Tapping Tee《塑料管道系统 聚乙烯(PE)开孔三通件 安装好的开孔三通上抗冲击应力的检测方法》.pdf EN 1716-1997 en Plastics Piping Systems - Polyethylene (PE) Tapping Tees - Test Method for Impact Resistance of an Assembled Tapping Tee《塑料管道系统 聚乙烯(PE)开孔三通件 安装好的开孔三通上抗冲击应力的检测方法》.pdf
  • EN 1717-2000 en Protection Against Pollution of Potable Water in Water Installations and General Requirements of Devices to Prevent Pollution by Backflow《水设施中防止饮用水被污染的保护及防治回流污染设备的一.pdf EN 1717-2000 en Protection Against Pollution of Potable Water in Water Installations and General Requirements of Devices to Prevent Pollution by Backflow《水设施中防止饮用水被污染的保护及防治回流污染设备的一.pdf
  • EN 1719-1998 en Adhesives for Paper and Board Packaging and Disposable Sanitary Products - Tack Mesurement for Pressure-Sensitive Adhesives - Determination of Loop Tack《纸张和制板 包装材料和.pdf EN 1719-1998 en Adhesives for Paper and Board Packaging and Disposable Sanitary Products - Tack Mesurement for Pressure-Sensitive Adhesives - Determination of Loop Tack《纸张和制板 包装材料和.pdf
  • EN 172 A2-2001 Personal eye protection - Sunglare filters for industrial use Amendment A2《个人眼睛保护 工业用太阳强光过滤器 修改案A2》.pdf EN 172 A2-2001 Personal eye protection - Sunglare filters for industrial use Amendment A2《个人眼睛保护 工业用太阳强光过滤器 修改案A2》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1