1、 WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2017-06-28 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 1 of 7 Enhanced hexalobular internal driving feature for bolts and screws 1 Scope This Ford Motor Company standard specifies the shape and basic dimensions of

2、enhanced hexalobular internal driving feature for bolts and screws including the gauging method. The curvature of the contour of the enhanced hexalobular internal driving feature is defined by the gauges specified in Tables 3, 4 and 5. Additional information which may be used when drawing the contou

3、r is given in the informative annex A. 2 Basic dimensions See Figure 1 and Table 1 Figure 1 Basic Dimensions Counterbore c: 0.13 mm maximum for socket No. 6 IP through 15 IP, 0.25 mm maximum over socket No. 15 IP Penetration depth I: See relevant product standard. NOTE: The contour of the bottom of

4、the socket beyond the gauge is at the option of the manufacturer. WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2017-06-28 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 2 of 7 Table 1 Basic Dimensions Dimensions in millimeters Hexalobular Socket No. Nominal Dimen

5、sions A (ref) B (ref) 6 IP 1.75 1.27 8 IP 2.39 1.75 10 IP 2.82 2.05 15 IP 3.35 2.4 20 IP 3.94 2.85 25 IP 4.52 3.25 30 IP 5.61 4.05 40 IP 6.76 4.85 45 IP 7.92 5.64 50 IP 8.94 6.45 55 IP 11.33 8.05 60 IP 13.44 9.6 Table 2 Enhanced Hexalobular Internal Drive Tolerances Dimensions in millimeters Socket

6、No. A B Ea Eb Fa Fb Drive Size Max Min Max Min Ref Ref Ref Ref 6 IP 1.7842 1.7416 1.3877 1.3454 0.1245 0.2313 0.0775 0.1843 8 IP 2.4241 2.3818 1.8653 1.823 0.1651 0.3051 0.1181 0.2581 10 IP 2.8508 2.8008 2.1802 2.1302 0.1969 0.359 0.145 0.3082 15 IP 3.3842 3.3342 2.612 2.562 0.2222 0.4233 0.1714 0.3

7、725 20 IP 3.9684 3.9184 3.0946 3.0446 0.2476 0.4945 0.1968 0.4437 25 IP 4.5649 4.4899 3.4981 3.4231 0.3023 0.565 0.2388 0.5015 30 IP 5.6571 5.5821 4.3973 4.3223 0.3505 0.6979 0.287 0.6344 40 IP 6.8134 6.7124 5.2894 5.1884 0.4229 0.8385 0.3467 0.7623 45 IP 7.9818 7.8808 6.2952 6.1942 0.4635 0.9839 0.

8、3874 0.9077 50 IP 8.9978 8.8968 6.9861 6.8851 0.5448 1.0964 0.4686 1.0202 55 IP 11.3854 11.2844 9.0842 8.9832 0.6236 1.4048 0.5347 1.3159 60 IP 13.4424 13.3418 10.5214 10.4208 0.7912 1.6518 0.6769 1.5375 Note: Min A & B dimensions are the max tool dimension +0.05mm to accommodate for max coating thi

9、ckness Max A & B dimensions are the Min A & B dimensions + the standard hexalobular drive tolerance E & F are reference values using max go-gage radius WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2017-06-28 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 3 of 7 3

10、 Gauging 3.1 Principle The enhanced hexalobular internal driving feature shall allow the GO gauge to enter freely to the penetration depth I as specified in the relevant product standards. The NO GO gauges shall not enter the enhanced hexalobular internal driving feature to a depth greater than the

11、fallaway allowance specified in Table 3. If the gage penetrates the internal drive feature outside of the specified fallaway allowance the part will be deemed unacceptable. Table 3 Fallaway Allowance Dimensions in millimeters Socket No. 6 IP 8 IP 10 IP 15 IP 20 IP 25 IP 30 IP 40 IP 45 IP 50 IP 55 IP

12、 60 IP Fallaway Allowance f 0.35 0.48 0.56 0.67 0.79 0.90 1.12 1.18 1.39 1.56 1.98 2.35 All gauging is performed with reference to the top surface of the head. In the case of oval or round top heads, measurements are taken from the actual intersection of the top surface of the head and the hexalobul

13、ar internal driving feature counter bore. When using a dial penetration gauge, this should be adjusted to zero while the gauge is pressed against a flat surface thereby compressing the plunger to make it flush with the gauge reference surface. See Figure 2. Figure 2 Penetration gauge in zero positio

14、n WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2017-06-28 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 4 of 7 3.2 GO gauge The GO gauge shall have dimensions within the limits specified in Table 4. Figure 3 Dimensions of the GO gauge Table 4 Limiting sizes of d

15、imensions of the GO gauge Dimensions in millimeters Socket A B Ea Eb Fa Fb H Num. Min Max Min Max Min Max Min Max Min Max Min Max 0.25 6 IP 1.7018 1.7094 1.3056 1.3132 0.1207 0.1245 0.2275 0.2313 0.0737 0.0775 0.1805 0.1843 2.79 8 IP 2.3419 2.3495 1.7831 1.7907 0.1613 0.1651 0.3013 0.3051 0.1143 0.1

16、181 0.2543 0.2581 2.79 10 IP 2.7610 2.7762 2.0904 2.1057 0.1892 0.1969 0.3514 0.3590 0.1384 0.1460 0.3006 0.3082 2.79 15 IP 3.2944 3.3096 2.5222 2.5375 0.2146 0.2222 0.4157 0.4233 0.1638 0.1714 0.3649 0.3725 2.79 20 IP 3.8786 3.8938 3.0048 3.0201 0.2400 0.2476 0.4868 0.4945 0.1892 0.1968 0.4360 0.44

17、37 3.81 25 IP 4.4501 4.4653 3.3833 3.3985 0.2946 0.3023 0.5574 0.5650 0.2311 0.2388 0.4939 0.5015 4.19 30 IP 5.5423 5.5575 4.2824 4.2977 0.3429 0.3505 0.6902 0.6979 0.2794 0.2870 0.6267 0.6344 4.70 40 IP 6.6726 6.6878 5.1486 5.1638 0.4153 0.4229 0.8309 0.8385 0.3391 0.3467 0.7547 0.7623 5.33 45 IP 7

18、8410 7.8562 6.1544 6.1697 0.4559 0.4635 0.9763 0.9839 0.3797 0.3874 0.9001 0.9077 5.97 50 IP 8.8570 8.8722 6.8453 6.8605 0.5372 0.5448 1.0888 1.0964 0.4610 0.4686 1.0126 1.0202 6.22 55 IP 11.2446 11.2598 8.9433 8.9586 0.6159 0.6236 1.3972 1.4048 0.5271 0.5347 1.3083 1.3159 6.48 60 IP 13.3020 13.317

19、2 10.3810 10.3962 0.7836 0.7912 1.6441 1.6518 0.6693 0.6769 1.5298 1.5375 7.92 WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2017-06-28 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 5 of 7 3.3 NOT GO gauges 3.3.1 Gauging the fallaway dimensions The fallaway gauge

20、 dimension limits are specified in Table 5. Figure 4 Dimensions of the fallaway gauge Table 5 Limiting sizes of dimensions of the fallaway gauge Dimensions in millimeters Socket Num. A K Fa Fb H V R -0.0000 +0.0076 Max -0.0000 +0.0038 -0.0000 +0.0038 0.25 +0.0000 -0.0038 Rad. 6 IP 1.7856 1.1834 0.11

21、56 0.2224 2.79 0.1894 0.03 8 IP 2.4257 1.5945 0.1562 0.2962 2.79 0.2632 0.03 10 IP 2.8524 1.8652 0.1841 0.3463 2.79 0.3133 0.05 15 IP 3.3858 2.2192 0.2095 0.4106 2.79 0.3776 0.05 20 IP 3.9700 2.6102 0.2349 0.4818 2.79 0.4487 0.05 25 IP 4.5669 2.9822 0.2896 0.5523 2.79 0.5066 0.05 30 IP 5.6591 3.7122

22、 0.3378 0.6852 4.70 0.6394 0.05 40 IP 6.8148 4.4673 0.4102 0.8258 5.33 0.7674 0.05 45 IP 7.9832 5.2636 0.4509 0.9712 5.97 0.9128 0.05 50 IP 8.9992 5.8920 0.5321 1.0837 6.22 1.0253 0.05 55 IP 11.4122 7.5562 0.6109 1.3921 6.48 1.3210 0.05 60 IP 13.495 8.8605 0.7658 1.6264 7.92 1.5552 0.05 WORLDWIDE FA

23、STENER STANDARD WB 900 Appendix F 2017-06-28 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 6 of 7 Table 6 Socket Gauging Penetration Tolerances Dimensions in millimeters I=Recess Gauge Penetration Head Type Pan 90 Raised Countersunk 90 Flat Countersunk A B C Rece

24、ss Ref. Suitable screw sizes for head forms and recess specified Head form dimensions as specified in: WB900, WB910 or WD900 Head form dimensions as specified in: WB900 or WD900 Head form dimensions as specified in: WB900 or WD900 Dimension (I) Dimension (I) Dimension (I) Max. Min. Max. Min. Max. Mi

25、n. 6 IP M2 0.81 0.68 0.72 0.6 0.72 0.6 10 IP M3 1.3 1.1 1.16 0.96 1.16 0.96 15 IP ST3.5 1.54 1.31 1.37 1.14 1.37 1.14 20 IP M4, ST4.2 1.81 1.54 1.62 1.34 1.62 1.34 25 IP M5, ST4.8 2.08 1.76 1.85 1.54 1.85 1.54 30 IP M6,ST6.3 2.58 2.19 2.3 1.91 2.3 1.91 40 IP M8 3.11 2.64 2.76 2.28 2.77 2.3 50 IP M10

26、 4.11 3.49 3.67 3.04 3.67 3.04 55 IP M12 5.21 4.58 NA NA NA NA WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2017-06-28 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 7 of 7 Annex A (Informative) Representation of enhanced hexalobular internal driving feature contour NOTE: The correlations of dimensions given in Figure A.1 are intended to support the drawing of the driving feature only, e.g. when using a CAD system. Scale to socket nominal dimension per Table 1 as needed. Figure A.1 Representation of enhanced hexalobular internal driving feature

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 16005-2013 Power operated pedestrian doorsets Safety in use Requirements and test methods German version EN 16005 2012《电动人行门 使用安全性 要求和试验方法 德文版本EN 16005-2012》.pdf DIN EN 16005-2013 Power operated pedestrian doorsets Safety in use Requirements and test methods German version EN 16005 2012《电动人行门 使用安全性 要求和试验方法 德文版本EN 16005-2012》.pdf
  • DIN EN 16006-2011 Animal feeding stuffs - Determination of the sum of fumonisin B and B in compound animal feed with immunoaffinity clean-up and RP-HPLC with fluorescence detection.pdf DIN EN 16006-2011 Animal feeding stuffs - Determination of the sum of fumonisin B and B in compound animal feed with immunoaffinity clean-up and RP-HPLC with fluorescence detection.pdf
  • DIN EN 16007-2011 Animal feeding stuffs - Determination of Ochratoxin A in animal feed by immunoaffinity column clean-up and High Performance Liquid Chromatography with fluorescenc.pdf DIN EN 16007-2011 Animal feeding stuffs - Determination of Ochratoxin A in animal feed by immunoaffinity column clean-up and High Performance Liquid Chromatography with fluorescenc.pdf
  • DIN EN 16009-2011 Flameless explosion venting devices German version EN 16009 2011《无火焰防爆通风装置 德文版本EN 16009-2011》.pdf DIN EN 16009-2011 Flameless explosion venting devices German version EN 16009 2011《无火焰防爆通风装置 德文版本EN 16009-2011》.pdf
  • DIN EN 16012-2015 Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance German version EN 16012 2012+A1 2015《建筑物的隔热性.pdf DIN EN 16012-2015 Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance German version EN 16012 2012+A1 2015《建筑物的隔热性.pdf
  • DIN EN 16014-2011 Hardware for furniture - Strength and durability of locking mechanisms German version EN 16014 2011《家具五金 锁紧机构的强度和耐用性 德文版本EN 16014-2011》.pdf DIN EN 16014-2011 Hardware for furniture - Strength and durability of locking mechanisms German version EN 16014 2011《家具五金 锁紧机构的强度和耐用性 德文版本EN 16014-2011》.pdf
  • DIN EN 16016-1-2011 Non destructive testing - Radiation methods - Computed tomography - Part 1 Terminology Trilingual version EN 16016-1 2011《非破坏性试验 辐射方法 计算机断层扫描 第1部分 术语 三种语言版本 EN .pdf DIN EN 16016-1-2011 Non destructive testing - Radiation methods - Computed tomography - Part 1 Terminology Trilingual version EN 16016-1 2011《非破坏性试验 辐射方法 计算机断层扫描 第1部分 术语 三种语言版本 EN .pdf
  • DIN EN 16016-2-2012 Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples German version EN 16016-2 2011《非破坏性试验 辐射方法 计算机断层扫描 第2.pdf DIN EN 16016-2-2012 Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples German version EN 16016-2 2011《非破坏性试验 辐射方法 计算机断层扫描 第2.pdf
  • DIN EN 16016-3-2012 Non destructive testing - Radiation methods - Computed tomography - Part 3 Operation and interpretation German version EN 16016-3 2011《非破坏性试验 辐射方法 计算机断层扫描 第3部分 .pdf DIN EN 16016-3-2012 Non destructive testing - Radiation methods - Computed tomography - Part 3 Operation and interpretation German version EN 16016-3 2011《非破坏性试验 辐射方法 计算机断层扫描 第3部分 .pdf