FORD WSB-M4P10-B1-2003 ANODIZING ORGANICALLY COLORED OVER ALUMINUM OR ALUMINUM ALLOY - INTERIOR TO BE USED WITH FORD WSS-M99P1111-A (Shown on WSB-M4P9-B1)《汽车内部用铝或铝合金表面的有机着色阳极化处理 .pdf

上传人:inwarn120 文档编号:749209 上传时间:2019-01-14 格式:PDF 页数:3 大小:72.62KB
下载 相关 举报
FORD WSB-M4P10-B1-2003 ANODIZING ORGANICALLY COLORED OVER ALUMINUM OR ALUMINUM ALLOY - INTERIOR  TO BE USED WITH FORD WSS-M99P1111-A  (Shown on WSB-M4P9-B1)《汽车内部用铝或铝合金表面的有机着色阳极化处理 .pdf_第1页
第1页 / 共3页
FORD WSB-M4P10-B1-2003 ANODIZING ORGANICALLY COLORED OVER ALUMINUM OR ALUMINUM ALLOY - INTERIOR  TO BE USED WITH FORD WSS-M99P1111-A  (Shown on WSB-M4P9-B1)《汽车内部用铝或铝合金表面的有机着色阳极化处理 .pdf_第2页
第2页 / 共3页
FORD WSB-M4P10-B1-2003 ANODIZING ORGANICALLY COLORED OVER ALUMINUM OR ALUMINUM ALLOY - INTERIOR  TO BE USED WITH FORD WSS-M99P1111-A  (Shown on WSB-M4P9-B1)《汽车内部用铝或铝合金表面的有机着色阳极化处理 .pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 08 28 Revised Para 3.0 inserted; Para 3.9 & 4 deleted 1987 12 14 SM/ER 1621 TC Released J.A. Burke, B. Manoukian, J.A. Ferrari, NAAO, J. Lines, EAO Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 1 of 3

2、 ANODIZING, BRIGHT OVER ALUMINUM OR ALUMINUM WSB-M4P9-B1 ALLOY - INTERIOR ANODIZING, BRIGHT OVER ALUMINUM OR ALUMINUM WSB-M4P9-B2 ALLOY - EXTERIOR ANODIZING, ORGANICALLY COLORED OVER ALUMINUM WSB-M4P10-B1 OR ALUMINUM ALLOY - INTERIOR ANODIZING, ELECTROLYTICALLY COLORED OVER WSB-M4P11-B1 ALUMINUM OR

3、ALUMINUM ALLOY - EXTERIOR OR INTERIOR 1. SCOPE These specifications define performance requirements for bright, organically colored, or electrolytically colored anodized aluminum finishes. 2. APPLICATION These specifications were released originally where a bright, combination colored and bright, an

4、d fully colored decorative and protective anodic finish is required on aluminum and aluminum alloy surfaces. Levels of performance are defined as follows: WSB-M4P9-B1 Bright interior part applications, e.g., bezels, moldings. WSB-M4P9-B2 Bright exterior part applications, e.g., bodyside, rocker, win

5、dow moldings, bumpers, etc. WSB-M4P10-B1 Colored interior part applications subjected to minimal ultraviolet (sunlight) and abrasion environments. WSB-M4P11-B1 Colored interior or exterior part applications that must withstand ultraviolet and abrasion exposures, e.g., bodyside, window moldings, etc.

6、 CAUTION: Based upon production and accelerated laboratory testing experience, anodic coatings are temperature sensitive and will craze (i.e., crack) when exposed to temperatures approaching 90 C and higher. Therefore, anodized aluminum parts must be masked prior to paint repair oven exposure. 3. RE

7、QUIREMENTS All requirements identified for each specification must be met to achieve acceptable field durability. No one requirement, exclusive of others, is capable of insuring satisfactory performance. Any deviations to the requirements of these specifications may be subject to additional performa

8、nce requirements. ENGINEERING MATERIAL SPECIFICATIONWSB-M4P9-B1/B2WSB-M4P10-B1WSB-M4P11-B1Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 3 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys S

9、tandard Requirements For Production Materials (WSS-M99P1111-A). 3.2 COMPOSITION OF THE ANODIC COATING The coating desired shall consist essentially of transparent hydrated aluminum oxide of uniform density and film thickness. Parts anodized and sealed to the WSB-M4P10-B1 specification shall have a s

10、uitable organic dye and/or pigment applied to achieve the desired appearance. The coloring of parts produced to the WSB-M4P11-B1 specification is achieved by the electrolytic deposition of metal salts in the anodic coating. 3.3 METAL FORMING All parts directly exposed to the exterior environment tha

11、t are processed to the requirements of these specifications shall be formed (fabricated) prior to anodizing to prevent crazing of the anodic coating. 3.4 ANODIC COATING THICKNESS, min (ASTM B 659) WSB-M4P9-B1 2.5 m WSB-M4P10-B1 2.5 m WSB-M4P9-B2 7.5 m WSB-M4P11-B1 7.5 m Note: The WSB-M4P11 minimum t

12、hickness requirement for both exterior and interior applications is 7.5 m because the appearance is coating thickness related. 3.5 ANODIC COATING WEIGHT, min (ASTM B 137) WSB-M4P9-B1 6.2 g/m2WSB-M4P10-B1 6.2 g/m2WSB-M4P9-B2 18.6 g/m2WSB-M4P11-B1 18.6 g/m2Note: The coating weight values obtained from

13、 the acid dissolution test sample (para 3.6) may be used for this test. 3.6 ACID DISSOLUTION TEST (A.D.T.), 6.0 max. (FLTM BQ 007-02) 3.7 ACCELERATED CORROSION RESISTANCE (CASS), 16 h There shall be no base metal (white corrosion) following the CASS test. ENGINEERING MATERIAL SPECIFICATIONWSB-M4P9-B

14、1/B2WSB-M4P10-B1WSB-M4P11-B1Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 3 of 3 3.8 WEATHERING RESISTANCE A demonstration of conformance to the following weathering resistance requirements is mandatory for all new bright or color anodizing suppliers seeking sou

15、rce approval and for all new colors prior to release by Styling. These requirements do not apply to production parts, either for initial sampling or routine control. 3.8.1 Weatherometer (ASTM D 3361) No color change of bright anodized coatings and no fading of colored coatings greater than originall

16、y approved. WSB-M4P9-B1 1000 h WSB-M4P9-B2 1000 h WSB-M4P11-B1 1000 h WSB-M4P10-B1 500 h 3.8.2 Florida Exposure Anodic coatings shall show no more checking, color change, chalking, or dulling than the originally approved samples when exposed as follows: WSB-M4P9-B1 12 months in Miami, Florida, WSB-M4P9-B2 facing south at a 5 angle WSB-M4P11-B1 off horizontal. WSB-M4P10-B1 6 months under glass (see AATCC Test Method 16C for type of glass) in Miami, Florida, facing south at a 45 angle.

展开阅读全文
相关资源
猜你喜欢
  • BS EN 60601-1-11-2010 Medical electrical equipment - General requirements for basic safety and essential performance - Collateral standard - Requirements for medical electrical eque.pdf BS EN 60601-1-11-2010 Medical electrical equipment - General requirements for basic safety and essential performance - Collateral standard - Requirements for medical electrical eque.pdf
  • BS EN 60601-1-11-2015 Medical electrical equipment General requirements for basic safety and essential performance Collateral Standard Requirements for medical electrical equipment.pdf BS EN 60601-1-11-2015 Medical electrical equipment General requirements for basic safety and essential performance Collateral Standard Requirements for medical electrical equipment.pdf
  • BS EN 60601-1-12-2015 Medical electrical equipment General requirements for basic safety and essential performance Collateral Standard Requirements for medical electrical equipment.pdf BS EN 60601-1-12-2015 Medical electrical equipment General requirements for basic safety and essential performance Collateral Standard Requirements for medical electrical equipment.pdf
  • BS EN 60601-1-2-2007 Medical electrical equipment General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Requirements and.pdf BS EN 60601-1-2-2007 Medical electrical equipment General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Requirements and.pdf
  • BS EN 60601-1-2-2015 Medical electrical equipment General requirements for basic safety and essential performance Collateral Standard Electromagnetic disturbances Requirements and .pdf BS EN 60601-1-2-2015 Medical electrical equipment General requirements for basic safety and essential performance Collateral Standard Electromagnetic disturbances Requirements and .pdf
  • BS EN 60601-1-6-2010 Medical electrical equipment - General requirements for basic safety and essential performance - Collateral standard - Usability《医用电气设备 基本安全性和基本性能的一般要求 并列标准 可用.pdf BS EN 60601-1-6-2010 Medical electrical equipment - General requirements for basic safety and essential performance - Collateral standard - Usability《医用电气设备 基本安全性和基本性能的一般要求 并列标准 可用.pdf
  • BS EN 60601-1-9-2008 Medical electrical equipment - Part 1-9 General requirements for basic safety and essential performance - Collateral standard - Requirements for environmentall.pdf BS EN 60601-1-9-2008 Medical electrical equipment - Part 1-9 General requirements for basic safety and essential performance - Collateral standard - Requirements for environmentall.pdf
  • BS EN 60601-2-1-1998 Medical electrical equipment - Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV《医用电气设备 在1 MeV到5 MeV范围内电子加速器的安全性详细要求.pdf BS EN 60601-2-1-1998 Medical electrical equipment - Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV《医用电气设备 在1 MeV到5 MeV范围内电子加速器的安全性详细要求.pdf
  • BS EN 60601-2-1-2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV《医疗电气设.pdf BS EN 60601-2-1-2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV《医疗电气设.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1