资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions 2014 11 24 N Status No replacement named D. Murtonen, NA 2006 05 03 Activated C. McComb Copyright 2014, Ford Global Technologies, LLC Page 1 of 2 FABRIC, VINYL COATED (PVC), WELL LINING WSS-M2F202-A NOT TO BE USED FOR NEW DESIGN 1. SCOPE The

2、material defined by this specification is a calendered polyvinyl chloride copolymer film laminated to a poly/cotton knit. 2. APPLICATION This specification was released originally for material used as a well lining for convertible tops. 3. REQUIREMENTS Material specification requirements are to be u

3、sed for initial qualification of materials. In addition to the requirements listed herein, this material shall meet all requirements of the WSS-M8P3-D3, PERFORMANCE, FLEXIBLE POLYMERIC FILM, INTERIOR QUALITY material performance specification. 3.1 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Mater

4、ial suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.2 MATERIAL CHARACTERISTICS Construction is a PVC facing to a poly/cotton backing. polyester: 65% cotton: 35% 3.3 APPEARANCE (FLTM BI 109-01) The color, pattern and finish

5、shall match the approved master sample, or shall be as specified on the engineering drawing. 3.4 WEIGHT, range (ASTM D 751, Sample Method) LSL USL Coating 641 g/m2 711 g/m2 Fabric 68 g/m2 98 g/m2 Total 709 g/m2 809 g/m2 ENGINEERING MATERIAL SPECIFICATION WSS-M2F202-A Copyright 2014, Ford Global Tech

6、nologies, LLC Page 2 of 2 3.5 RESISTANCE TO TEAR, Trapezoid, min (ASTM D 1117) Warp 22 N Fill 22 N 3.6 BREAKING STRENGTH, min (ASTM D 751, Grab Method) Warp 222 N Fill 198 N 3.7 ADHESION OF VINYL FILM TO BACKING FABRIC, min (FLTM BN 151-05, Method A/ISO 2711) Warp 18 N Fill 18 N 3.8 FILTERED XENON WEATHEROMETER, min (FLTM B0 116-01/ISO 105-A02/AATCC Evaluation Procedure 1) 451.2 kJ Rating 4 4. GENERAL INFORMATION The information below is provided for clarification and assistance in meeting the requirements of this specification. 4.1 RECYCLING CODE PVC,LF

展开阅读全文
相关资源
猜你喜欢
  • DIN CLC TS 50534-2011 Railway applications - Generic system architectures for onboard electric auxilary power systems German version CLC TS 50534 2010《轨道交通 船上电气辅助动力系统用通用系统架构 德文版本CL.pdf DIN CLC TS 50534-2011 Railway applications - Generic system architectures for onboard electric auxilary power systems German version CLC TS 50534 2010《轨道交通 船上电气辅助动力系统用通用系统架构 德文版本CL.pdf
  • DIN CLC TS 50537-1-2011 Railway applications - Mounted parts of the traction transformer and cooling system - Part 1 HV bushing for traction transformers German version CLC TS 5053.pdf DIN CLC TS 50537-1-2011 Railway applications - Mounted parts of the traction transformer and cooling system - Part 1 HV bushing for traction transformers German version CLC TS 5053.pdf
  • DIN CLC TS 50537-2-2011 Railway applications - Mounted parts of the traction transformer and cooling system - Part 2 Pump for insulating liquid for traction transformers and reacto.pdf DIN CLC TS 50537-2-2011 Railway applications - Mounted parts of the traction transformer and cooling system - Part 2 Pump for insulating liquid for traction transformers and reacto.pdf
  • DIN CLC TS 50537-3-2011 Railway applications - Mounted parts of the traction transformer and cooling system - Part 3 Water pump for traction converters German version CLC TS 50537-.pdf DIN CLC TS 50537-3-2011 Railway applications - Mounted parts of the traction transformer and cooling system - Part 3 Water pump for traction converters German version CLC TS 50537-.pdf
  • DIN CLC TS 50537-4-2011 9375 Railway applications - Mounted parts of the traction transformer and cooling system - Part 4 Gas and liquid actuated (Buchholz) relay for liquid immers.pdf DIN CLC TS 50537-4-2011 9375 Railway applications - Mounted parts of the traction transformer and cooling system - Part 4 Gas and liquid actuated (Buchholz) relay for liquid immers.pdf
  • DIN CLC TS 50539-22-2010 3750 Low-voltage surge protective devices - Surge protective devices for specific application including d c - Part 22 Selection and application principles .pdf DIN CLC TS 50539-22-2010 3750 Low-voltage surge protective devices - Surge protective devices for specific application including d c - Part 22 Selection and application principles .pdf
  • DIN CLC TS 50544-2010 Low voltage d c surge protective device for traction systems - Selection and application rules for surge arresters German version CLC TS 50544 2010《牵引系统用低压直流电.pdf DIN CLC TS 50544-2010 Low voltage d c surge protective device for traction systems - Selection and application rules for surge arresters German version CLC TS 50544 2010《牵引系统用低压直流电.pdf
  • DIN CLC TS 50546-2013 Railway applications - Rolling stock - 3-phase shore (external) supply system for rail vehicles German version CLC TS 50546 2013《轨道交通 轨道车辆 轨道车辆用三相(外部)供应系统 德文版.pdf DIN CLC TS 50546-2013 Railway applications - Rolling stock - 3-phase shore (external) supply system for rail vehicles German version CLC TS 50546 2013《轨道交通 轨道车辆 轨道车辆用三相(外部)供应系统 德文版.pdf
  • DIN CLC TS 60034-18-33-2011 Rotating electrical machines - Part 18-33 Functional evaluation of insulation systems - Test procedures for form-wound windings - Multifactor evaluation.pdf DIN CLC TS 60034-18-33-2011 Rotating electrical machines - Part 18-33 Functional evaluation of insulation systems - Test procedures for form-wound windings - Multifactor evaluation.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1