FORD WSS-M2F202-A-2014 FABRIC VINYL COATED (PVC) WELL LINING TO BE USED WITH FORD WSS-M99P1111-A .pdf

上传人:explodesoak291 文档编号:752941 上传时间:2019-01-14 格式:PDF 页数:2 大小:44.19KB
下载 相关 举报
FORD WSS-M2F202-A-2014 FABRIC VINYL COATED (PVC) WELL LINING  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第1页
第1页 / 共2页
FORD WSS-M2F202-A-2014 FABRIC VINYL COATED (PVC) WELL LINING  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions 2014 11 24 N Status No replacement named D. Murtonen, NA 2006 05 03 Activated C. McComb Copyright 2014, Ford Global Technologies, LLC Page 1 of 2 FABRIC, VINYL COATED (PVC), WELL LINING WSS-M2F202-A NOT TO BE USED FOR NEW DESIGN 1. SCOPE The

2、material defined by this specification is a calendered polyvinyl chloride copolymer film laminated to a poly/cotton knit. 2. APPLICATION This specification was released originally for material used as a well lining for convertible tops. 3. REQUIREMENTS Material specification requirements are to be u

3、sed for initial qualification of materials. In addition to the requirements listed herein, this material shall meet all requirements of the WSS-M8P3-D3, PERFORMANCE, FLEXIBLE POLYMERIC FILM, INTERIOR QUALITY material performance specification. 3.1 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Mater

4、ial suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.2 MATERIAL CHARACTERISTICS Construction is a PVC facing to a poly/cotton backing. polyester: 65% cotton: 35% 3.3 APPEARANCE (FLTM BI 109-01) The color, pattern and finish

5、shall match the approved master sample, or shall be as specified on the engineering drawing. 3.4 WEIGHT, range (ASTM D 751, Sample Method) LSL USL Coating 641 g/m2 711 g/m2 Fabric 68 g/m2 98 g/m2 Total 709 g/m2 809 g/m2 ENGINEERING MATERIAL SPECIFICATION WSS-M2F202-A Copyright 2014, Ford Global Tech

6、nologies, LLC Page 2 of 2 3.5 RESISTANCE TO TEAR, Trapezoid, min (ASTM D 1117) Warp 22 N Fill 22 N 3.6 BREAKING STRENGTH, min (ASTM D 751, Grab Method) Warp 222 N Fill 198 N 3.7 ADHESION OF VINYL FILM TO BACKING FABRIC, min (FLTM BN 151-05, Method A/ISO 2711) Warp 18 N Fill 18 N 3.8 FILTERED XENON WEATHEROMETER, min (FLTM B0 116-01/ISO 105-A02/AATCC Evaluation Procedure 1) 451.2 kJ Rating 4 4. GENERAL INFORMATION The information below is provided for clarification and assistance in meeting the requirements of this specification. 4.1 RECYCLING CODE PVC,LF

展开阅读全文
相关资源
猜你喜欢
  • ANSI IEEE C37.22-1997 Preferred Ratings and Related Required Capabilities for Indoor AC Medium-Voltage Switches Used in Metal-Enclosed Switchgear (Replaces NEMA C37.22-1997).pdf ANSI IEEE C37.22-1997 Preferred Ratings and Related Required Capabilities for Indoor AC Medium-Voltage Switches Used in Metal-Enclosed Switchgear (Replaces NEMA C37.22-1997).pdf
  • ANSI IEEE C37.22-2003 Preferred Ratings and Related Required Capabilities for Indoor AC Medium-Voltage Switches Used in Metal-Enclosed Switchgear (ANSI C37.22-1997 Replaces NEMA C3.pdf ANSI IEEE C37.22-2003 Preferred Ratings and Related Required Capabilities for Indoor AC Medium-Voltage Switches Used in Metal-Enclosed Switchgear (ANSI C37.22-1997 Replaces NEMA C3.pdf
  • ANSI IEEE C37.232-2011 Common Format for Naming Time Sequence Data Files (COMNAME)《命名时序数据文件的通用格式标准(COMNAME)》.pdf ANSI IEEE C37.232-2011 Common Format for Naming Time Sequence Data Files (COMNAME)《命名时序数据文件的通用格式标准(COMNAME)》.pdf
  • ANSI IEEE C37.239-2010 Common Format for Event Data Exchange (COMFEDE) for Power Systems《电力系统用项目数据交换(COMFEDE)公用格式标准》.pdf ANSI IEEE C37.239-2010 Common Format for Event Data Exchange (COMFEDE) for Power Systems《电力系统用项目数据交换(COMFEDE)公用格式标准》.pdf
  • ANSI IEEE C37.244-2013 Guide for Phasor Data Concentrator Requirements for Power System Protection Control and Monitoring.pdf ANSI IEEE C37.244-2013 Guide for Phasor Data Concentrator Requirements for Power System Protection Control and Monitoring.pdf
  • ANSI IEEE C37.40-2003 Service Conditions and Definitions for High-Voltage Fuses Distribution Enclosed Single-Pole Air Switches Fuse Disconnecting Switches and Accessories《高压熔断器 配电封.pdf ANSI IEEE C37.40-2003 Service Conditions and Definitions for High-Voltage Fuses Distribution Enclosed Single-Pole Air Switches Fuse Disconnecting Switches and Accessories《高压熔断器 配电封.pdf
  • ANSI IEEE C37.47-2011 Specifications for High-Voltage ( 1000 V) Distribution Class Current-Limiting Type Fuses and Fuse Disconnecting Switches《高压(γ>1000 V)分布类限流器式熔断器和熔断器断开开关的标准规格》.pdf ANSI IEEE C37.47-2011 Specifications for High-Voltage ( 1000 V) Distribution Class Current-Limiting Type Fuses and Fuse Disconnecting Switches《高压(γ>1000 V)分布类限流器式熔断器和熔断器断开开关的标准规格》.pdf
  • ANSI IEEE C37.48-2005 Guide for the Application Operation and Maintenance of High-Voltage Fuses Distribution Enclosed Single-Pole Air Switches Fuse Disconnecting Switches and Acces.pdf ANSI IEEE C37.48-2005 Guide for the Application Operation and Maintenance of High-Voltage Fuses Distribution Enclosed Single-Pole Air Switches Fuse Disconnecting Switches and Acces.pdf
  • ANSI IEEE C37.63-2013 Standard Requirements for Overhead Pad-Mounted Dry-Vault and Submersible Automatic Line Sectionalizers for Alternating Current Systems Up to 38 kV.pdf ANSI IEEE C37.63-2013 Standard Requirements for Overhead Pad-Mounted Dry-Vault and Submersible Automatic Line Sectionalizers for Alternating Current Systems Up to 38 kV.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1