1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev 02 2012 05 15 N Status No usage or replacement N. Benipal, NA 2009 05 22 Revised Revision to viscosity range Titles revised A. Knell 2004 10 25 Activated C. Bezant Controlled document at www.MATS Copyright 2012, Ford Global Technologies,

2、Inc. Page 1 of 2 PUR LACQUER, SEALANT, JAGUAR LAND ROVER ONLY WSS-M4J214-A PUR LACQUER, SEALANT, HARDENER/ACTIVATOR, WSS-M4J214-A2 JAGUAR LAND ROVER ONLY NOT TO BE USED FOR NEW DESIGN 1. SCOPE The materials defined by these specifications are polyurethane sealer and associated polyurethane hardener/

3、activator. They are suitable for sealing purposes on wood veneer assemblies prior to finishing with a polyester lacquer. 2. APPLICATION These specifications WSS-M4J214-A/A2 were released for materials used for wooden decorative automotive components. 3. REQUIREMENTS Material specification requiremen

4、ts are to be used for initial qualification of materials. When in the fully assembled form the veneer assembly must comply with the Material specification requirements as specified on the engineering drawing. 3.1 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers mu

5、st conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.2 MATERIAL PROPERTIES 3.2.1 Color Assembly to be as per Master samples 3.2.2 Viscosity at 23 C WSS-M4J214-A 55 - 63 sec, 2mm cup 3.2.3 Drying/Curing, at 20 - 23C WSS-M4J214-A & A2: Dust Dry 2 Hours Min Reco

6、ating 1 - 24 Hours Min 3.2.4 Storage Stability Shelf life: When stored between 20 - 23C WSS-M4J214-A & A2 6 Months ENGINEERING MATERIAL SPECIFICATION WSS-M4J214-A2 Copyright 2012, Ford Global Technologies, Inc. Page 2 of 2 3.2.5 Handling at 20 - 23 C 3.2.6 Mixing ratio WSS-M4J214-A1 - 100 parts by weight sealing lacquer to WSS-M4J214-A2 - 100 parts by weight hardener/activator 3.5 PERFORMANCE PROPERTIES The material shall be of uniform quality, free from foreign materials and properties detrimental to normal production use.

展开阅读全文
相关资源
猜你喜欢
  • DLA MIL-DTL-24558 23 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 403 1 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf DLA MIL-DTL-24558 23 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 403 1 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf
  • DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf
  • DLA MIL-DTL-24558 25 B-2011 TERMINAL BOXES CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 418 1 - SIX BUS LUGS FOR TWO 3-CONDUCTOR 250 MCM CABLES SYMBOL NO 418 2 S.pdf DLA MIL-DTL-24558 25 B-2011 TERMINAL BOXES CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 418 1 - SIX BUS LUGS FOR TWO 3-CONDUCTOR 250 MCM CABLES SYMBOL NO 418 2 S.pdf
  • DLA MIL-DTL-24558 26 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 572 1 SIX BRANCH LUGS FOR TWO 3-CONDUCTOR 40 MCM CABLES SIX BUS LUGS FOR T.pdf DLA MIL-DTL-24558 26 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 572 1 SIX BRANCH LUGS FOR TWO 3-CONDUCTOR 40 MCM CABLES SIX BUS LUGS FOR T.pdf
  • DLA MIL-DTL-24558 27 C-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 573 1 TWELVE BRANCH TERMINALS FOR FOUR 3-CONDUCTOR 40 MCM CABLES SIX MAIN .pdf DLA MIL-DTL-24558 27 C-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 573 1 TWELVE BRANCH TERMINALS FOR FOUR 3-CONDUCTOR 40 MCM CABLES SIX MAIN .pdf
  • DLA MIL-DTL-24558 28 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 574 1 EIGHTEEN BRANCH TERMINALS FOR SIX 3-CONDUCTOR 40 MCM CABLES SIX MAIN《.pdf DLA MIL-DTL-24558 28 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 574 1 EIGHTEEN BRANCH TERMINALS FOR SIX 3-CONDUCTOR 40 MCM CABLES SIX MAIN《.pdf
  • DLA MIL-DTL-24558 29 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 575 1 SIX BRANCH TERMINALS FOR TWO 3-CONDUCTOR 75 MCM CABLES SIX MAIN BUS .pdf DLA MIL-DTL-24558 29 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 575 1 SIX BRANCH TERMINALS FOR TWO 3-CONDUCTOR 75 MCM CABLES SIX MAIN BUS .pdf
  • DLA MIL-DTL-24558 3 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 10-TERMINAL 30-WIRE 600 VOLTS SYMBOL NO 528.pdf DLA MIL-DTL-24558 3 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 10-TERMINAL 30-WIRE 600 VOLTS SYMBOL NO 528.pdf
  • DLA MIL-DTL-24558 30 B-2011 TERMINAL BOXES CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 576 1 - TWO CIRCUITS FOR 150 MCM CABLE ONE CIRCUIT FOR 200 MCM CABLE AND .pdf DLA MIL-DTL-24558 30 B-2011 TERMINAL BOXES CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 576 1 - TWO CIRCUITS FOR 150 MCM CABLE ONE CIRCUIT FOR 200 MCM CABLE AND .pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1