FORD WSS-M8B19-A1-2017 WINDSHIELD WASHER FLUID ISOPROPANOL ALCOHOL PRE-DILUTED INITIAL FILL TO BE USED WITH FORD WSS-M99P1111-A .pdf

上传人:cleanass300 文档编号:754028 上传时间:2019-01-14 格式:PDF 页数:4 大小:58.03KB
下载 相关 举报
FORD WSS-M8B19-A1-2017 WINDSHIELD WASHER FLUID ISOPROPANOL ALCOHOL PRE-DILUTED INITIAL FILL  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第1页
第1页 / 共4页
FORD WSS-M8B19-A1-2017 WINDSHIELD WASHER FLUID ISOPROPANOL ALCOHOL PRE-DILUTED INITIAL FILL  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第2页
第2页 / 共4页
FORD WSS-M8B19-A1-2017 WINDSHIELD WASHER FLUID ISOPROPANOL ALCOHOL PRE-DILUTED INITIAL FILL  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第3页
第3页 / 共4页
FORD WSS-M8B19-A1-2017 WINDSHIELD WASHER FLUID ISOPROPANOL ALCOHOL PRE-DILUTED INITIAL FILL  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev. 0 2017 11 14 Released S. Gould, EUControlled document at www.MATS Copyright 2017, Ford Global Technologies, LLC Page 1 of 5 WINDSHIELD WASHER FLUID, ISOPROPANOL ALCOHOL, WSS-M8B19-A1 PRE-DILUTED, INITIAL FILL 1. SCOPE The material define

2、d by this specification is an Isopropanol Alcohol based solution containing surfactants and other additives for improved cleaning efficiency and freeze point depression. See requirements in Table 1 for freeze point temperature by region. 2. APPLICATION The diluted material is intended for locations

3、that lack equipment to dilute the concentrate, have poor water quality, or chose to avoid mixing altogether. The dilution ratio is established to meet the freeze point requirement for the market where the vehicle is sold. 3. REQUIREMENTS 3.1 APPROVED SOURCES This specification requires the use of ap

4、proved sources. Only the sources identified on the Ford Approved Source List (ASL) can be used when this specification is listed on the drawing, CAD file, or other documents. The list of approved sources is located within Ford at or available externally through a Ford Materials Engineer. 3.2 CONDIT

5、IONING AND TEST CONDITIONS All test values are based on material conditioned for not less than 24 h prior to testing in a controlled environment of 23 +/- 2 C and 50 +/- 5% relative humidity. Testing of the material should occur in the conditioning environment or soon after removal. 3.3 STANDARD REQ

6、UIREMENTS FOR PRODUCTION MATERIALS 3.3.1 In addition to the control plan, the supplier and affected Material Engineering activity shall establish mutually agreed upon frequency of testing for the ongoing product verification plan and include in Supplement A. 3.4 APPROVAL INFORMATION This specificati

7、on was released to allow this material to be purchased by Ford Purchasing for use in a Ford facility. The specification number is also the part number in WERS. Post production uses a different format for WERS The freezing point of pre-diluted initial fill must be clearly marked on all deliveries. 3.

8、5 PERFORMANCE REQUIREMENTS Materials being evaluated for initial approval must meet WSS-M14P19-A or latest revisions. ENGINEERING MATERIAL SPECIFICATION WSS-M8B19-A1 Copyright 2017, Ford Global Technologies, LLC Page 2 of 4 3.6 COLOR Clear blue (Visual) or as agreed to by The Ford facility 3.7 SPECI

9、FIC GRAVITY AT 15.6 C Report (ASTM D891) Specific Gravity is dependent on temperature and suppliers concentration/composition. Since multiple suppliers will be approved to this specification, refer to the Ford Approved Source List or suppliers MSDS or certificate of analysis. Typical specific gravit

10、y is 0.925 kg/L for the pre-diluted material. 3.8 FREEZE POINT OF DILUTED WINDSHIELD WASHER FLUID (GOST 28084) Less than North America Market (FNA) -30C South America Market (FSAO) 0C Europe (FoE) Market -20C Asia Pacific and Africa Market (APA) 0C China Market -40C Russian Market -30C 4. GENERAL IN

11、FORMATION The information given below is provided for clarification and assistance in meeting the requirements of these specifications. Contact for questions concerning Engineering Material Specifications. Windshield washer fluid (WWF) has the following typical properties. 4.1 WSS-M8B19-A1 ANALYTIC

12、AL TESTING 4.1.1 Non-Volatiles, 43.0 Isopropyl Alcohol 46.0 Mono Ethylene Glycol 6.0 Detergent/Surfactants 5 Alkalinity Source 2 Rust Preventative Source 2 Stable, Identifying Dye Trace 4.1.4 pH 8.0 10.0 (ASTM E70) ENGINEERING MATERIAL SPECIFICATION WSS-M8B19-A1 Copyright 2017, Ford Global Technolog

13、ies, LLC Page 3 of 4 4.1.5 Surface Tension at 25 C, 31.4 mN/m (DIN EN 14370) 4.2 APPROVAL OF MATERIALS Suppliers desiring approval of their materials shall first obtain an expression of interest from Purchasing, Design or Product Development, and Materials Engineering. The supplier shall submit a co

14、mpleted copy of their laboratory test reports, signed by a qualified and authorized representative of the test facility, demonstrating full compliance with all the requirements of the Material Specification. Tested material samples must be available for review upon request and kept for a minimum of

15、one year. Upon request, the supplier will review the associated quality control documents (Process Failure Mode and Effects Analysis, Control Plans, Certification testing) with Ford. 4.3 SUPPLIERS ONGOING RESPONSIBILITY All materials must be equivalent in all characteristics to the material upon whi

16、ch approval was originally granted. Prior to making any changes to the material originally approved, whether or not such changes affect the materials ability to meet the specification requirements, the supplier shall notify the affected Supplier Technical Assistance (STA), Purchasing, and Materials

17、Engineering activities of the proposed changes (with reasons) by submission of a completed Suppliers Request for Engineering Approval, SREA. For parts and components using Ford Engineering Material Specifications, all samples tested to the specifications for Design Verification (DV), Production Veri

18、fication (PV) and Production Part Approval Process (PPAP) sign off must be kept until Job 1. 4.4 RESTRICTED SUBSTANCE MANAGEMENT STANDARD Substance restrictions imposed by regulations or Company direction applies to the materials addressed by this document. The restrictions are identified in the Res

19、tricted Substance Management Standard WSS-M99P9999-A1 which is updated yearly. It is the suppliers responsibility to comply with this standard on a continuing basis through IMDS and or GMAP reporting. 5. SUMMARY OF REVISIONS TABLE 1 Freezing Point of Isopropanol (2-Propanol) based on Water Solutions

20、 Freezing Point Isopropanol Concentration (% by volume) 0 10 20 30 40 50 60 70 80 90 100 Temperature F 32 25 30 5 0 -5 -10 -20 -35 -70 -130 Temperature C 0 -4 -7 -15 -18 -21 -23 -29 -37 -57 -90 Data is based on the mean experimental values. ENGINEERING MATERIAL SPECIFICATION WSS-M8B19-A1 Copyright 2

21、017, Ford Global Technologies, LLC Page 4 of 4 SUPPLEMENT A Supplier_Date_ Product Name_ Product Code_Batch No._ Manufacturing Plant Location_ Physical/Chemical/Performance Properties ASTM Test Frequency Method Manufacturing Limits Test Result of test WSB-M8B19-A1 Non-volatiles, % D1353 _ _ _ Specif

22、ic Gravity D891 _ _ _ Viscosity, mm2/s D445 At 22 C _ _ _ At - 17.8 C _ _ _ WSB-M8B19-A1 Please state dilution ratio (concentrate/water)_ Please state subsequent referenced freeze point from dilution _ pH E70 _ _ _ Specific Gravity D891 _ _ _ Surface Tension, N/m D1331 _ _ _ Viscosity, mm2/s D445 At 22 C _ _ _ At - 17.8 C _ _ _Freeze Point, C D1177 _ _ _ Supplier Signature_ Title_ Material Engineering Concurrence_